Para Español, vea páginas 6-10.
Pour le français, consulter les pages 11-15.
π H-3472
®
SANITAIRE
COMPACT
1-800-295-5510
uline.com
CANISTER VACUUM
SAFETY
NOTE: When using an electrical appliance,
basic precautions should always be followed,
including the following: READ ALL INSTRUCTIONS
BEFORE USING THIS VACUUM CLEANER.
WARNING! To reduce the risk of fire,
electric shock, or injury:
• Do not use outdoors or on wet surfaces.
• Do not leave vacuum cleaner when plugged in.
Turn off the switch and unplug the electrical cord
when not in use and before servicing.
• Do not allow to be used as a toy. Close attention is
necessary when used by or near children.
• Use only as described in this manual. Use only the
manufacturer's recommended attachments.
• Do not use with damaged cord or plug. If vacuum
cleaner is not working as it should, has been
dropped, damaged, left outdoors, or dropped into
water, return it to a service center before using.
• Do not pull or carry by cord, use cord as a handle,
close door on a cord, or pull cord around sharp
edges or corners. Do not run vacuum cleaner over
cord. Keep cord away from heated surfaces.
• Do not use extension cords or outlets with
inadequate current-carrying capacity.
• Turn off all controls before unplugging.
• Do not unplug by pulling on cord. To unplug, grasp
the plug, not the cord.
• Do not handle plug or vacuum with wet hands.
• Do not put any object into openings. Do not use with
any opening blocked; keep free of dust, lint, hair or
anything that may reduce airflow.
PAGE 1 OF 15 0118 IH - 3 472
• This vacuum cleaner creates suction and contains a
revolving brush roll. Keep hair, loose clothing, fingers
and all parts of the body away from openings and
moving parts.
• Do not place cleaner on furniture or stairs as the
brush roll may cause damage.
• Do not vacuum anything that is burning or smoking,
such as cigarettes, matches, or hot ashes.
• Do not use without dust bag or filter(s) in place.
• Belt pulleys can become hot during normal use. To
prevent burns, avoid touching the belt pulley when
servicing the drive belt.
• Use extra care when cleaning on stairs.
• Do not use to pick up flammable or combustible
liquids such as gasoline, or use in areas where they
may be present.
• Store your cleaner indoors in a cool, dry area.
• Keep your work area well lighted.
• Unplug electrical appliances before vacuuming them.
• Do not oil the motor or the brush roll. The motor and
brush roll are permanently sealed and lubricated.
CAUTION! THIS APPLIANCE MUST BE GROUNDED.
If it should malfunction or break down,
grounding provides a path of least resistance
for electrical current to reduce the risk of
electric shock.
NOTE: The appliance is equipped with a
cord having an equipment-grounding
conductor and grounding plug. The plug
must be plugged into an appropriate outlet
that is properly installed and grounded
in accordance with all local codes and
ordinances.

ASSEMBLY
CAUTION! Fully assemble the cleaner before
using. Make sure on/off switch is in the off
position before plugging in.
1. Snap the hose into the inlet in the bag cover of the
canister. The hose can be released by depressing the
two release buttons. (See Figure 1)
Figure 1
2. The power cord is stored on the bottom of the canister
by wrapping around the cord hooks. The front hook
swivels to provide a quick release feature.
(See Figure 2)
Figure 2
4. Twist the slip ring (A) to adjust the amount of suction.
The tool caddy (B) holds the upholstery tool (C), the
dusting brush (D) and the crevice tool (E).
(See Figure 4)
Figure 4
D
A
C
B
E
F
3. The shoulder strap snaps into the handle in two
locations. (See Figure 3)
Figure 3
G
5. The wands (F) adjust to different cleaning heights by
using either a single wand or both attached together.
The combination floor tool (G) works on both carpet
and hard surfaces by moving the lever on the floor
tool head to either the carpet or bare floor position.
(See Figure 4)
6. Optional HEPA filter snaps onto the rear housing. The
crevice tool can also be stored in the handle (H).
(See Figure 5)
Figure 5
H
PAGE 2 OF 15 0118 IH - 3 472

OPERATION
1. Locate the on/off switch on the top of the canister, in
front of the handle. (See Figure 6)
Figure 6
2. Press with hand or foot once to turn on. Press again
to shut off.
MAINTENANCE
CHANGING DUST BAG
CAUTION! Turn off vacuum and unplug the
electrical cord before changing the dust bag
or cleaning the motor filter. Never operate the
vacuum cleaner without the dust bag or filter.
AUTOMATIC MOTOR SHUT-OFF
To protect from overheating, this vacuum cleaner is
equipped with a thermostat which automatically shuts off
the motor if it overheats. If overheating occurs complete
the following steps:
1. Turn off the switch and unplug the cleaner.
2. Check the hose for clogs, the bag to see if it needs
to be changed or if the filter needs to be cleaned or
replaced.
3. If the cleaner does not resume operation within
30 minutes, contact Uline customer service:
1-800-295-5510.
3. Insert finger into upper left notch and pull to remove
bag. (See Figure 9)
Figure 9
1. Open the bag cover by pushing down on the latch.
(See Figure 7)
Figure 7
2. Fold bag closure flap down and push behind the
rubber seal. (See Figure 8)
Figure 8
4. Check motor filter. If necessary, replace or clean by
rinsing under warm water. Install when completely
dry. (See Figure 10)
Figure 10
PAGE 3 OF 15 0118 IH - 3 472

MAINTENANCE CONTINUED
5. Open bag folds slightly. Place bag in the cleaner.
Tuck bag corners under collar. Close bag cover
making sure it latches completely. (See Figure 11)
Figure 11
HEPA FILTER MAINTENANCE
Check the HEPA filter (optional) with each dust bag
change. Replace twice a year or after every six bag
changes as needed.
1. Grasp the bottom clips (I) and pull out and down to
release the upper filter tabs (J). (See Figure 12)
Figure 12
J
I
2. To replace the filter, insert upper filter tabs firmly
under the rear housing tabs (K) and pivot filter until
the bottom clips on the filter click securely into
place on the cleaner. (See Figure 13)
Figure 13
K
ROUTINE MAINTENANCE
DAILY
1. Dust Bag – Before each use, check the disposable
paper dust bag and replace if full or nearly full.
2. Supply Cord and Plug – Check supply cord and
plug for any cuts or damage. If damaged, have
the supply cord and plug assembly replaced by a
qualified Sanitaire repair center.
3. Motor – If there are unusual sounds or if poor
performance occurs, the motor should be inspected
immediately by a qualified Sanitaire repair center.
WEEKLY
1. Filter (optional) – Check the filter for clogs and
replace as needed.
MONTHLY
1. Cleaning – Inspect and clean the vacuum.
2. Electrical – Inspect the cord assembly for wear.
3. Motor – A qualified Sanitaire repair center should
make a routine check of the motor every 6 months.
Inspect the motor immediately if there are any
unusual sounds or if poor performance occurs.
4. Filter – Check the filter for clogs and replace as
needed. (Recommend replacement is twice per
year or every six bag changes.)
PAGE 4 OF 15 0118 IH - 3 472

TROUBLESHOOTING
OPERATING ISSUE RECOMMENDATIONS
There is little or no suction. 1. Twist the slip ring to adjust the amount of suction. Cover the holes
Vacuum turns off while in use. 1. The vacuum may turn off due to overheating. Turn off the switch
Vacuum has a burning smell. 1. Check to see if cord is damaged or if there is a clog in hose.
Vacuum does not clean carpet. 1. Be sure hose is securely on the vacuum.
in the wand to increase suction. (See Page 2)
2. There may be a clog in the hose.
3. Take the hose and wands apart and remove the clog.
4. Open the lid. Ensure that the paper bag is not full and is correctly
positioned. If full, replace bag.
5. HEPA filter may need to be changed. Replace twice per year or
after every 6 bag changes.
and unplug.
2. Check to make sure there are no clogs, the bag is not full and
that the filter does not need to be changed. Replace or clean
parts if needed.
3. If vacuum does not resume operation after 30 minutes, contact
Uline customer service at 1-800-295-5510.
2. Check hose for clogs.
π
CHICAGO • ATLANTA • DALLAS • LOS ANGELES • MINNEAPOLIS • NYC/PHILA • SEATTLE • MEXICO • CANADA
1-800-295-5510
PAGE 5 OF 15 0118 IH - 3 472
uline.com