UIS NGW-240 Quick Install Manual

Quick Install Guide
Power On
1
Plug in the power adapter or insert the battery.
USB
Gateway
Device Joining
2
WPS
USB
SET
LAN
WAN
DC IN 12V
STAY
Panel Console Contact Sensor
2.1 Gateway vs ALL RF devices
1. Short press the SET button at the back of the Gateway. Wait until the Alarm LED blinks red before releasing the SET button.
2. Short press the SET button at the back of the device until the LED blinks green.
3. Wait for few seconds until both LEDs (on the Gateway and device) turned off. This indicates the binding process is successful.
2.2 Router(Power Switch) vs ALL RF devices
1. Short press the SET button on the Power Switch until the LED blinks green.
2. Short press the SET button at the back of the device until the LED blinks green.
2 sensor, press both the and buttons until the screen blinks.
For CO
3. Wait for few seconds until both LEDs (on the Router and device) turned off. This indicates the binding process is successful.
Note:
• RF devices are including Sensor, Console, Switch, and Transducer.
Gateway Panel Console
Connect to
AWAY
USB
USB
SET button
STAY
SET button
SET/Reset Reboot
WPS
SET
LAN
WAN
DC IN 12V
Contact Sensor and other devices
NGW-240…
Power Switch
SET button
CO2
SET
SET button
CO
2
Monitor
ALARM
SET
push and hold “▲” & “▼”
together until the screen blinks
Quick Install Guide
3
On-Site Installation
3.1 Panel Console(keypad)
1. Mount the bracket on the wall at an appropriate height. For easy access, it is recommended to install the device near the front gate.
2. Open the battery cover and install the batteries into the battery compartments. Then close the bottom cover firmly.
Note:
• The device supports both city power and battery (alkaline AA battery x 2,
non-rechargeable, for 2 hours emergency use).
• Once CPN-240 is unexpectedly unplugged from the bracket under system
arm mode, the tamper-proof detection will trigger the alarm.
3.2 Contact Sensor
1. Mount the bracket on the frame side of the door or window, and then put the reed on the bracket.
2. Place the magnet on the door or window side. Align
the arrow point of the reed by less than 10mm
distance. Then stick on it.
Note:
• Due to tamper-proof design, please make sure the
installation is stable to avoid any false alarm.
3.3 Motion Sensor
1. Mount the bracket on the wall, at the height of 1.8 to
2.4 m. Do not install it upside down.
2. The scan pattern is illustrated in the figure on the right.
• The effective distance is 8~10m, at 2m height.
• 150-degree at horizontal position.
• 25-degree at vertical position.
3. Pet immune detection could be effective if it meets the following criteria:
• Height: less than 50cm.
• Weight: less than 6kg.
4. To avoid false alarm, do the following:
• Be sure the installation is stable.
• Do not place the device to face any light source
directly.
• Never face the sensor to the place that pests can
climb up directly.
0 1 2 3 4 5 6 7 8 9 10 11 12 13
80
80
1.8~2.4m
70
60
50
B
50
60
70
Detection area : (Unit=Meter)
40
30
20
A
10
10
20
30
40
(M)
0
2
1
2m
0 1 2 3 4 5 6 7 8 9 10 11 12 13
(M)
10mm
Distance:10m
(M)
AB
Quick Install Guide
3
On-Site Installation
3.4 Smoke Sensor
1. Install the batteries into the battery compar tments and close the bottom
cover firmly.
2. Mount the bracket on the ceiling. When the sensor detects the smoke, it will automatically trigger the alarm and also send out the signal to the Gateway. To manually turn off the alarm sound, push the button on the front side of the sensor.
Note:
• Because of fool-proof design, install in the battery first before closing the
case by turning the cover counterclockwise.
3.5 RSSI - RF signal test
Short press the SET button at the back of the sensor twice. The signal strength is indicated by its LED indicator:
*Good: The LED blinks green (very quickly) for 15 seconds *Normal: The LED blinks green (quickly) for 15 seconds *Poor: The LED blinks green (slowly) for 15 seconds (not recommended) *No Signal: The LED blinks red light for 3 seconds then turned off (not recommended)
It is highly recommended to install the devices at “Good” or “Normal” signal strength to ensure a good
quality wireless signal.
Note:
• RSSI devices are including Button Console, Contact Sensor, Motion Sensor, Smoke Sensor,
AI Transducer, DI Transducer, and Siren.
3.6 CO2 Sensor
1. Hang it on the wall through the rear holds or place it on a stable
surface.
Note:
• It is recommended to place the device inside the room to
detect the CO
2 concentration. It also supports both
temperature and humidity detection.
2. Push the SET button and then press both the and buttons to set up the concentration threshold.
CO
2
Monitor
ALARM
SET
3.7 Alarm Switch(Siren)
LED button
1. Power on the device either by using the power adapter or
installing the battery.
2. Once the alarm is triggered, the alarm volume is approximately 90dB. To turn off the alarm sound, press the upper LED button.
3.8 Power Switch
1. Plug it into a wall socket and connect to any household
LED button
appliance with less than 10A.
2. Press the LED button to manually turn on/off the power relay.
Note:
• Tamper-proof function is only available for Panel Console, Contact Sensor, Motion Sensor, and Siren.
• Alarm switch (siren) is highly recommended to be joined/installed at last to avoid the false alarm caused by unexpected tamper-proof.
Buzzer
Socket
Quick Install Guide
4
Reset to Default
4.1 Gateway
a. Push and hold the SET button for 15 seconds until the ALARM LED blinks red.
OR
b. Access the Web Management and select System > Reset.
Note:
• If the Gateway is turned off while doing the reset process, the device will be
displayed as “off-line” on the Web Management when the gateway is turned on
on the next time. In this case, you have to delete the device one by one via Web
Management.
4.2 Panel Console(keypad)
1. Push and hold the SET button until the screen shows “Reseting”.
2. Wait until the “CPN-240 Reset OK!” message appears on the screen and
then the device will automatically reboot. After booting, it will show “Welcome
to CPN-240!” for few seconds, indicating the device has been reset to the
factory default successfully.
Note:
• You cannot reset the panel console while arming.
4.3 Device(sensor, switch or transducer)
1. Push and hold the SET button at the back of the sensor for 5 seconds.The
LED will blink green at the same time and then turn off.
2. After 2~3 seconds, the LED will blink red and then turn off to complete the
reset process.
4.4 Device(CO
Push and hold the button for 5 seconds.The LED will quickly blink once to complete the reset process.
5
Full Arm / Partial Arm / Disarm / Panic Operation
Use the combination keys to operate the system using Panel Console(keypad) or Button Console(key-fob) without
accessing the Web Management or APP.
Operation Full Arm Partial Arm Disarm Panic
Panel Console + Password + Password or + Password Long press
Button Console Press “FA” Press “PA” Press “DA Long press “FA
2 Sensor)
AWAY
STAY AWAY STAY
SET button
AWAY
SET/Reset Reboot
[■■■■■]
Reseting
SET button
SET
CO
2
Monitor
ALARM
SET
STAY
LED
Push and hold
USB
WPS
USB
LAN
WAN
DC IN 12V
SET button
“▲” button
SET
FUNC
6
Get connected with Gateway by Wi-Fi Interface
The gateway supports Wi-Fi connectivity with basic AP function and the default SSID is “HOME-AP”.
1. Open the Wi-Fi interface on the notebook or tablet PC to search the SSID as above to get connected.
2. Open browser (IE 7.0 or above) and enter the default IP “192.168.19.254” to get connected with the Gateway by
login default password “123”.
7
Get connected with Gateway by Wired Ethernet Interface
Make sure the type of network connection that you are using is DHCP.
1. Connect the LAN ports of the Gateway and notebook using an Ethernet cable.
2. Open browser (IE 7.0 or above) and enter the default IP “192.168.19.254” to get connected with the Gateway by
login default password “123”.
REFER TO THE USER’S MANUAL FOR MORE INFORMATION.
Loading...