
DL419
DL419
True RMS
600V 1000A
CAT IV
NCV
MAX/
MIN
LRA
Inrush
Zero
DC/
Rel
RANGE
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
μ
A
A
V
MFD
DL419
True RMS
600V 1000A
CAT IV
V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
True RMS Digital Clamp-On
Multimeter
V
INSTRUCTION MANUAL
ENGLISH
CAT IV
600V 1000A
DL419
True RMS
O
D
L
T
E
A
T
E
C
T
FUNCTIONS
• AC/DC Voltage
• AC/DC Current
• AC/DC MicroAmps
• Audible continuity ............................................
• Resistance ....................................................
............................................
............................................
........................................
NCV
NAVIGATION
A
μ
A
Zero
DC/
Rel
HOLD
• Diode test ....................................................
• Capacitance ..................................................
MAX/
MIN
LRA
V
Inrush
MFD
RANGE
FEATURES
G
E
O
R
• True RMS
• LRA Inrush current measurement
• Data hold mode
HOLD
• MIN/MAX (All ranges except Capacitance)
• Rel/DC A Zero mode
....................................
................
Min/Max
Rel/Zero
• Back-lit display ................................................
• Non-contact voltage detect ....................................NCV
• Magnetic mount
• Autoranging measurements with manual ranging capability
• Bar Graph
a. The bar graph shows an approximate analog representation of a
measurement.
b. The bar graph responds much faster than the digital display.
c. The scale of the bar graph is zero to the maximum reading of
the selected range.
• Auto-Power-Off: After 30 minutes of non-use
• Low battery: is displayed if battery voltage drops below
operating voltage.
• Press briefly to turn the meter on
• Press and hold “HOLD” while turning on
to disable auto power off.
• Press and hold to turn the meter off
• Default is AC Volts
The new user interface allows direct access from any mode.
• Press to select DC µA measurement mode.
• Press a second time for AC µA.
• Press to select AC Amps.
• Press a second time for DC Amps.
• Press to select continuity.
MFD
• Press a second time for resistance.
• Press a third time for capacitance and a fourth time for diode.
INRUSH
A
A
NCV
MAX/
MIN
LRA
Inrush
μ
V
INRUSH
CAT III 1000V
CAT IV 600V
MFD
Zero
RANGE
WARRANTY
The DL419 is warranted to be free from defects in materials and workmanship
for a period of two year from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi’s option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge.
For more information on warranty and service:
www.ueitest.com • Email: info@ueitest.com
1-800-547-5740 • FAX: (503) 643-6322
This warranty gives you specific legal rights. You may also have other rights
which vary from state to state.
BATTERY REPLACEMENT
• When indicator is displayed on the LCD, batteries must be replaced.
• Remove the back screw and replace 2 x AAA batteries.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period
of storage in extreme conditions exceeding the limits mentioned in the
Specifications section, allow the instrument to return to normal operating
conditions before using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its
accessories shall be subject to a separate collection and correct
disposal.
DC/
Rel
PLEASE
RECYCLE
GENERAL SPECIFICATIONS
• Altitude: Operating - up to 2000m (6,561 ft.)
Storage - 10,000m (32,808 ft.)
• Humidity: 80% max
• Operating Temperature: 32°F to 104°F (0°C to 40°C) at < 75% R.H
• Storage Temperature: -4°F to 140°F (-20°C to 60°C) at < 80% R.H
• Relative humidity: 0% to 80% at 32°F to 95°F (0°C to 35°C),
0% to 70% at 32°F to 131°F (0°C to 55°C)
• Temperature Coefficient: Nominal 0.1 x (Specified accuracy) / °C
(<18°C or >28°C ; <64°F or >82°F)
• Pollution degree: 2
• Display: 3-3/4 digits 4000 counts single LCD display with 20 segments
bar graph
• Refresh Rate: 3 times/sec
• Overrange: "OL" is displayed
• Polarity: Automatic(no indication for positive polarity) ; Minus(-) sign
for negative polarity
• Dimensions: 10.6" x2.5" x 1.5"
• Weight: 16.8oz.
• Calibration: Accurate for one year
• CAT Rating: CAT IV 600V, CAT III 1000V
• Certifications: ETL & C-ETL Listed IEC61010-2-032
• Battery type: 2 x 1.5V AAA or LR03
• Silicon Test Lead: IEC61010-2-031
• Accuracy: ± (% of reading + # of least significant digits)
WARNINGS
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring a known voltage or
current.
• Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
• Do not use the meter during electrical storms, or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from the metal
probe contacts when making measurements.
• Do not open the meter to replace batteries while the probes are connected.
• Use caution when working with voltages above 60V DC, or 25V AC RMS.
Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace batteries
if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out power before
measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use Personal Protective
Equipment (PPE) to prevent shock and arc blast injury.
SYMBOLS USED ON LCD
~
AC Measurement DC Measurement
Negative DC Value
Overload: Range Exceeded
O.L.
Low Battery
Minimum Reading
MIN
Relative / Zero Mode
Voltage Measurement Diode Test
V
Resistance in Ohms
Ω
MicroAmps
µA
m
Milli ( x 10
-3
)
nF/µF
Auto Range Active
AT
Auto Power-Off Active
Apo
Hold Active
HOLD
Maximum Reading
M
AX
Current in Amps
A
Kilo ( x 103)
k
Mega ( x 106 )
M
Nanofarad/Microfarad
INTERNATIONAL SYMBOLS
AC Alternating Current Warning or Caution
~
DC Direct Current Dangerous levels
DC/AC Voltage or Current Double Insulated Class II
Ground
AC Source
Safe for disconnect
from live conductors
• Press to select AC Volts.
V
• Press again to select DC Volts.
• Non-Contact Voltage Detection key is used to detect power with a
sensor located at the tip of the clamp head and indicates positive
response with an audible alarm and visual LED indicator light just
above the “NCV” button.
NCV
MAX/
MIN
• Do not use non-contact voltage detector to determine if there
is current in the wire. Detection operation could be affected by
socket design, insulation thickness, type and other factors.
• Voltage indicator light may also light when voltage is present on
the meter’s input jack or from external interference sources such
as motors, flashlights etc.
• Press to enter Max / Min mode; the largest and smallest values
will be saved while in this mode.
• Press repeatedly to alternate between the maximum and
minimum readings.
• Press for 2 seconds to return to live reading and clear the stored
maximum and minimum values.
Note: Select range prior to selecting Min/Max to capture large
values
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
• AT is displayed on LCD only during auto ranging mode.
RANGE
Note: Select range prior to Min/Max for best results.
x1x1
• Press to zero any offset in Volts AC/DC, DC µA, Amps AC/DC.
Zero
DC/
Rel
HOLD
◊ Used to monitor change from the present displayed value
• Required during DC Amp measurement to establish a zero level
DO NOT use Zero DC/Rel mode at voltages greater than
1000V.
• Press to hold the reading on the display. Press again to return to
live reading.
• Press and hold "work light" key for 2 seconds to turn on. Press and
hold again to turn off.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Copyright © 2015 UEi. All Rights Reserved
10093 01/15

V
O
L
T
A
G
E
D
E
T
E
C
T
O
R
AC / DC Voltage: < 1000V
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
CAT IV
600V 1000A
Capacitance (MFD)
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
CAT IV
600V 1000A
AC/DC Amps: < 1000A
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
CAT IV
600V 1000A
Single
Conductor
Only
DL419
True RMS
V
A
A
μ
Zero
NCV
MAX/
MIN
LRA
DC/
Rel
MFD
V
RANGE
Inrush
INRUSH
x1 =
x2 =
CAT III 1000V
CAT IV 600V
Use CAT III rated leads or higher.
Do not attempt to measure more than 1000V.
Keep hands below line when measuring high current levels.
• Select AC or DC voltage source.
Features:
NCV
DC Voltage Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV
4V 1mV
40V 10mV
400V 100mV
1000V 1V ± (0.8% + 10 digits)
AC Voltage Measurement
Range Resolution Accuracy Overload Protection
400mV 0.1mV
4V 1mV
40V 10mV
400V 100mV
1000V 1V
True RMS: 45Hz to 400Hz
• Display shows resistance.
• Buzzer sounds if less than 40Ω.
Features:
NCV
Audible Continuity
Overload Protection Open Circuit Voltage
600V RMS
Threshold Approx : < 40Ω
MAX/
MIN
Rel
± (0.5% + 4 digits)
± (2.0% + 5 digits) 1000V RMS
Continuity
MAX/
MIN
HOLD
Resistance: < 40MΩ
V
D
E
O
L
T
E
C
NCV
MAX/
MIN
LRA
Inrush
<
T
A
G
E
T
O
R
RANGE
CAT IV
600V 1000A
DL419
True RMS
A
μ
V
INRUSH
CAT III 1000V
CAT IV 600V
0.44V
HOLD
1000V
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
A
Zero
DC/
Rel
MFD
RANGE
x1 =
x2 =
x3 =
x4 =
MFD
MFD
DL419
True RMS
A
A
μ
Zero
NCV
MAX/
MIN
LRA
DC/
Rel
MFD
V
RANGE
Inrush
INRUSH
x1 =
x2 =
x3 =
MFD
x4 =
CAT III 1000V
CAT IV 600V
Features:
NCV
HOLD
Range Resolution Accuracy Overload Protection
nF 0.01nF
40.00
400.0
nF 0.1nF
MFD
4.000uF 0.001µF
40.00uF 0.01µF
400.0uF 0.1µF
2000uF 1µF
GOOD DIODE
Reverse Bias
Displays "OL"
Forward Bias
Displays approx.
voltage drop
BAD DIODE
Open Diode
Displays "OL"
Both directions
• Forward voltage drop if forward biased.
• “O.L.” if reverse biased.
Features:
NCV
Diode Test
Range Open Circuit Voltage Test Current (Typical) Overload Protection
2.0V< 1.6V DC 0.25mA 600V RMS
± (3.5% + 6 digits) 600V RMS
Diode
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
CAT IV
600V 1000A
DL419
True RMS
A
A
μ
Zero
NCV
MAX/
MIN
LRA
Inrush
CAT III 1000V
CAT IV 600V
DC/
Rel
MFD
V
RANGE
INRUSH
or
MAX/
MIN
AC/DC Low Amps: < 2000µA
HOLD
CAT IV
600V 1000A
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
MFD
x1 =
x2 =
x3 =
MFD
x4 =
'0' Both directions
DL419
True RMS
A
A
μ
Zero
NCV
MAX/
MIN
LRA
Inrush
DC/
Rel
MFD
V
RANGE
INRUSH
A
x1 =
CAT III 1000V
CAT IV 600V
• Center wire in guides for best accuracy.
• Opposing currents cancel (use line-splitter when necessary).
Features:
NCV
Zero
DC/
Rel
MAX/
MIN
LRA
Inrush
RANGE
DC Amps Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A ± (2.5% + 15 digits)
1000A 1A ± (1.5% + 8 digits)
AC Amps Measurement
Range Resolution Accuracy Overload Protection
40A 0.01A ± (2.9% + 15 digits)
1000A 1A ± (1.9% + 8 digits)
True RMS: 45Hz to 400Hz
LRA Inrush
The UEi LRA Inrush is programmed to properly capture the starting current for
compressor motors.
• Select AC Amps
• Select the range capable of capturing the maximum value
• Press and hold LRA Inrush for two seconds – INRUSH will now be shown
on the screen
• Activate compressor and read value on the display
• Press and hold LRA Inrush for two seconds to exit
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
CAT IV
600V 1000A
DL419
True RMS
A
A
μ
Zero
LRA
Inrush
NCV
MAX/
MIN
LRA
Inrush
V
INRUSH
CAT III 1000V
CAT IV 600V
DC/
Rel
MFD
RANGE
Zero DC Amps / Rel
V
O
D
L
T
E
A
T
E
G
C
E
T
O
R
x2 =
HOLD
1000V RMS400A 0.1A ± (1.5% + 8 digits)
1000V RMS400A 0.1A ± (1.9% + 8 digits)
INRUSH
CAT IV
600V 1000A
DL419
NCV
MAX/
MIN
LRA
Inrush
True RMS
A
μ
V
INRUSH
A
Zero
DC/
Rel
MFD
RANGE
MFD
x1 =
x2 =
x3 =
CAT III 1000V
CAT IV 600V
• Do not measure resistance on a live circuit.
Features:
NCV
Rel
MAX/
MIN
RANGE
Range Resolution Accuracy Overload Protection
400
Ω 0.1Ω
4kΩ 1Ω
40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
40MΩ 10kΩ
± (1.0% + 4 digits)
± (2.0% + 4 digits)
x4 =
HOLD
600V RMS
MFD
DL419
True RMS
A
A
μ
Zero
NCV
MAX/
MIN
LRA
DC/
Rel
MFD
V
RANGE
Inrush
INRUSH
x1 =
x2 =
CAT III 1000V
CAT IV 600V
Features:
NCV
DC Low Amps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
400µA 0.1µA
2000µA 1µA
AC Low Amps Measurement -Test lead input
Range Resolution Accuracy Overload Protection
400µA 0.1µA ± (2.0% + 5 digits)
2000µA 1µA ± (1.5% + 5 digits)
True RMS: 45Hz to 400Hz (Crest factor < 3 : 1 )
Rel
MAX/
MIN
RANGE
HOLD
± (1.2% + 3 digits) 2000µA / 600V RMS
2000µA / 600V RMS
CAT IV
600V 1000A
DL419
True RMS
A
A
μ
Zero
NCV
MAX/
MIN
LRA
DC/
Rel
MFD
V
RANGE
Inrush
INRUSH
Zero
DC/
Rel
x1 = on
CAT III 1000V
CAT IV 600V
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
x2 = off