C160 OVERVIEW
C
o
m
b
u
s
i
o
n
A
n
a
l
y
z
e
r
C160
C
O
C
O
2
T
E
M
P
Status
v3
O2/Eff
CO/CO2
T1
Power button
Display lines
1 through 6
Status bar line
Navigation
Protective boot with built-in magnets
Pump
CO/CO2 Test screen
O2/Eff Test screen
Status screen
Menu screen
USB charging port
Log & Print
LED Water Trap Full Indication
Water Trap Window
K-type temperature input
Combustion hose input
Water trap drain plug
C
o
m
b
u
s
t
i
o
n
A
n
a
l
y
z
e
r
C160
C
O
C
O
2
T
E
M
P
Status
v3
O2/Eff
CO/CO2
MENU SCREEN - C160 START UP
Press
Button for 2 seconds. The analyzer will
”Power”
perform a 60 second purge. This should be done in fresh air.
Rotate Selector Dial to MENU to set up or customize your settings.
Selected parameter are centered, highlighted with arrow icons on either side.
Use Press
and buttons to scroll menu options, to select and edit a parameter.
Press and buttons to change contents of a field.
Press button to scroll fields.
Press to enter content and move to next field.
STATUS SCREEN
Rotate Selector Dial to STATUS to view parameters.
Selected Fuel Ti = Ambient Temperature CAL
= Days remaining until calibration
Press
and buttons to scroll Status Bar
options.
Time, Pump Status, Battery Status Fuel Type
Date
Change Fuel Type in STATUS SCREEN
Press and buttons to the currently selected fuel. Press and Hold button until arrows indicate fuel
edit mode is activated. The
and to scroll fuel types.
Press
to select desired fuel.
CO/CO2
O2/Eff
Status
v3
C160
C
o
m
b
u
s
P
M
E
T
2
O
C
O
C
r
e
z
y
l
a
n
t
i
A
o
n
BEFORE TESTING
CHECKLIST
o Clean particle filter o Water trap and probe line are
free of water
o All hose and thermocouple
connections are properly secured
o Water trap is fitted correctly o Power on and zero o Flue gas probe is sampling
ambient FRESH air
Remove the rubber boot and red drain plug. Allow the water to drain out. Re-insert the rubber plug and replace boot cover.
COMBUSTION ANALYSIS
Remove protective rubber boot. Remove water trap from analyzer. Remove particle filter from spigot and replace with new one. Reattach trap and boot.
T1
Insert flue probe into combustion input. Insert K-type temperature probe into input T1.
Insert flue probe into stack. Adjust cone so the probe tip is approximately at the center of
Rotate rotary dial to O2/Eff for O2/Eff Test Screen parameters.
CO/CO2
O2/Eff
Status
v3
C
o
m
b
u
C160
s
t
i
o
P
M
E
T
2
O
C
O
C
r
e
z
y
l
a
n
A
n
the stack.
NOTE: If there is no hole, check with service and installation instructions of appliance for best testing method or check with your local authority on best practice
CO/CO2
O2/Eff
Status
O2/Eff displays O2 (%), Gross Efficiency, Flue Temperature.
v3
C
o
m
b
u
Rotate rotary dial to CO/CO2 for CO/CO2 Test Screen parameters.
C160
s
t
i
o
P
M
E
T
2
O
C
O
C
r
e
z
y
l
a
n
A
n
CO/CO2 displays CO (ppm), Losses calculated, Excess Air %, Make any adjustments need­ed for proper combustion and wait for changes in readings (Repeat necessary).
CHANGE FUEL TYPE
CO/CO2
O2/Eff
Status
v3
C
o
m
b
C160
u
s
t
i
P
M
E
T
2
O
C
O
C
r
e
z
y
l
a
n
A
o
n
Rotate rotary dial to O2/Eff or CO/CO2 setting.
Press button until the Fuel Type displays on the Status Bar.
Press and Hold until two arrow icons display.
Press and buttons to scroll fuel selections.
Press to select fuel.
PRINTING & LOGGING
FLUE 2
FLUE 2
To Print: Align printer (sold separately) above Analyzer.
VIEW SAVED LOGS
Rotate the dial to MENU. Press
is selected between two arrow icons. Press to select.
button until the LOGS
During testing, Press to start printing.
Press again to abort.
Screen displays all saved LOGS. With VIEW selected in the Status
Bar, Press to select.
To Log: During testing, Press and Hold
to log a report.
To view these Logs, see View Saved Logs section.
Press and buttons to scroll Test Report categories.
Press to select a category.
Line 1 displays the LOG number on screen.
To view another LOG, Press and buttons to NEXT.
Press to advance to next log. Repeat until you reach desired LOG.
To print the LOG, Press and buttons until PRINT is selected between two arrow icons. Press to select to start printing.
To EXIT, Press and buttons until EXIT is selected between two arrow icons. Press
to EXIT screen.
Repeat until return to MENU screen.
POST TESTING
Remove the probe from the flue and allow analyzer to purge with fresh air until readings return to zero. O2 to 20.9%, CO to Zero
CAUTION: probe tip will be HOT.
BATTERIES
The analyzer is fitted with 3 (AA) size rechargeable batter­ies. Observe correct polarity whe n replacing.
Always check operation immediately after battery replacement.
Do not leave batteries in unit for extended periods of non-use.
POWERING OFF
When you power off the C160, there is a 10 second purge.
CAUTION
Make sure you do not exceed the analyzer’s operating specifications.
Do not exceed the flue probes maximum temperature (1112˚F
• dependent on flue probe used)
Do not exceed the analyzer’
• Do not put the analyzer on a hot surface
Do not exceed the water trap’
• Do not let the particle filter become dirty and blocked
s internal temperature range 112°F (50°C)
s level
WARNING
Do not recharge with Alka­line batteries fitted. Alkaline batteries are not rechargeable. Attempting to recharge alkaline batteries may result in product damage and create a fire risk.
Time and Date will need to be reset after changing batteries.
Always dispose batteries using approved disposal methods that protect the environment.
,
WARRANTY
The C160 combustion analyzer is warranted for one year including sensors. If within the warranty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UEi’s option. This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper mainte­nance (calibration). Batteries and consequential damage resulting from failed batteries are not covered by warranty. Any implied warranties, including but not limited to implied warranties of merchantability
tness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss
and fi of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss. A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. Instruments out of warranty will be repaired (when repairable) for a service charge. Warranty only covers hardware and does not extend to software applications. Contact UEi for specific warranty and service information.
T
his warranty gives you specific legal rights. You may also have other rights which vary from state to state.
ANNUAL RECERTIFICATION SERVICES
Complete care for your C160 series combustion analyzer.
When you:
Request Recertification or Service Online Within 1 Year of Purchase or Service
UEi will:
6-Year Warranty: All UEi combustion analyzers have a standard 1-year warranty. Each recertification includes a 30-point inspection and extends the warranty for 1 more year for up to 6 years from the date of warranty.
24-hour Service:
and service through UEi Service+ are shipped back on the next business day.
Free Shipping: UEi Service+ offers free shipping both to and from our service center. When customers book their recertifi receive a prepaid UPS Ground shipping label.
Register Online
Registering you analyzer online is quick and easy. Just log in or setup an account, it only takes a couple of minutes. Once logged in you can register you analyzer by providing some product information and uploading a proof-of-purchase.
When it’s time to request recertifcation, just log into your account, select the analyzer, select the service and place your order.
Test Equipment Depot - 800.517.8431 - 5 Commonwealth Ave, MA 01801
Analyzers received for standard recertification
cation, they
TestEquipmentDepot.com
Copyright © 2021 Kane USA Inc. All Rights Reserved. 202109 0821
Loading...