UEi COA1 Instruction Manual

COA1
Carbon Monoxide Detector Adapter
INSTRUCTION MANUAL
ENGLISH
COA1
LOW BAT
REQUIRES Compatible mobile device and the
FREE downloadable App, “CoChecker"
1-800-547-5740
www.ueitest.com • email: info@ueitest.com
WARNING : uses, to be used as personal safety device or medical applications. Refer to IMPORTANT
SAFETY WARNINGS section for more details.
NOTE: This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operations.
The COA1 is an ambient CO detector and not intended for in-flue stream
FCC INFORMATION
INFORMATION TO THE USER
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING : could void the user’s authority to operate the equipment.
Any changes or modifications not expressly approved by the manufacturer
IMPORTANT SAFETY WARNINGS
WARNING
Read entire Safety Notes section regarding potential hazard and proper instructions before using this tester. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument.
WARNING
• To ensure safe operation and service of the tester, follow these instructions. Failure to observe these warnings can result in severe injury or death.
• This meter is designed for trade professionals who are familiar with the hazards of their trade. Observe all recommended safety procedures that include use of personal protective equipment.
• Carbon monoxide is life threatening even at relatively low concentrations. Be sure you understand the risks before investigating potential leaks.
• Do not use the tester if it appears damaged.
• Always adhere to national and local safety codes.
• This COA1 is specified to read Carbon Monoxide from 1-999ppm. The app may continue to read above this threshold. Professional safety precautions are recommended above 35ppm.
• Threshold safety levels are set to industry standards. By customizing these levels to higher COppm thresholds, users risk personal safety. These setting are saved and used after exiting and relaunching the App. To reset back to industry standards set the levels to: Green ≤ 10 Orange ≤ 35 Red.
CAUTION
• The COA1 is designed for ambient testing only. DO NOT place the instrument in flue gas or warm air streams.
• The COA1 is not designed for in-flue detection. Readings more than 999 ppm will damage the sensor in the COA1, even if readings continue above the 999ppm range.
• Ensure that the sensor vent at the top of the instrument is free from obstruction.
• When zeroing the COA1, the adapter should be in fresh air. The COA1 uses an electrochemical sensor, which are subject to long-term drift pending use and CO levels during use. Calibration services are available at UEi Recertification Centers. Call or visit us online for more information.
NOTE: A quick instrument check can be performed by the smoke from a blown out match. Let smoke enter the
vent
. This will cause the indicated CO level to increase.
FEATURES
• CO reading direct on your device
• Reads CO up to 999 ppm
• Detects CO to 1 ppm
• Use with compatible iOS® or Android™ smart devices
• Free App displays 3 visual danger levels
• App allows logging and emailing capabilities
• Low Battery Indicator
GENERAL SPECIFICATIONS
• Operating Temperature: 32˚ to 104˚F (0˚ to 40˚C)
• Dimensions: 2.4 x 1.17 x 1.02” (61 x 30 x 26mm)
• Item Weight: 0.05oz
• Battery Type: CR2032
• Accuracy: ± (3% + 1 ppm)
• App Compatibility: iOS®; iPhone 4X and up running iOS7 and higher iPhone 7
(requires use of Lightning to 3.5mm headphone jack adapter) Android™; Galaxy S4, Nexus 5, HTC One running Android 4.4 or higher
NOTE:
Requires compatible mobile device and FREE downloadable App “CoChecker”.
Hold/Capture Value
Warning or Caution
SYMBOLS
Maximum measured value displayed
Loading...
+ 2 hidden pages