u-blox UBX-20031225 User Manual

Author
Date
Topic
Release Note
UBX-20031225 Len Albertsson 9 July 2020
Copying, reproduction, modification or disclosure to third parties of this document or any part thereof is only permitted with the express written permission of u-blox. The information contained herein is provided “as is” and u-blox assumes no liability for its use. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time. For most recent documents, visit www.u-blox.com. Copyright© u-blox AG.
Contents
1 General Information 2
1.1 Scope 2
1.2 Supported hardware 2
1.2.1 Ordering codes for the modules upgradeable to u-connectXpress v3.0.0 2
1.3 Released software package 2
1.4 Related documentation 2
1.5 Released software tools 2
2 New features 3
2.1 Multiple central support 3
2.2 Connection status information 3
2.3 Changeable MAC address 3
2.4 Configurable reconnect timer 3
3 Notes and limitations 3
3.1 Solved limitations 3
3.2 Known limitations 4
UBX-20031225 1/4 u-connectXpress v3.0.0 for ANNA-B112
Product name
Ordering code
Type number
Software version
ANNA-B112
ANNA-B112-01B
ANNA-B112-01B-00
v2.0.0
ANNA-B112
ANNA-B112-00B
ANNA-B112-00B-00
v1.0.0
File
Description
ANNA-B112_3.0.0.zip
u-connectXpress v3.0.0 software package
1 General Information
1.1 Scope
This release note describes the u-connectXpress v3.0.0 software for ANNA-B112 modules.
1.2 Supported hardware
1.2.1 Ordering codes for the modules upgradeable to u-connectXpress v3.0.0
It is possible to update all ANNA-B112 modules and evaluation kits to u-connectXpress v3.0.0. See the ANNA-B1 System Integration manual [2] for information about the software update procedure.
NOTE: Updating to v3.0.0 will restore the default configuration settings.
1.3 Released software package
The software package is available for download from www.u-blox.com.
1.4 Related documentation
[1] ANNA-B112 Data Sheet, UBX-18011707 [2] ANNA-B112 System Integration Manual, UBX-18009821 [3] Using u-connectXpress software User Guide, UBX-16024251 [4] u-connect AT Commands Manual, UBX-14044127
The documents are available for download from www.u-blox.com
1.5 Released software tools
The s-center version 5.0 or later is recommended for evaluation of u-connectXpress v3.0.0. The s-center application is available for download from www.u-blox.com.
UBX-20031225 2/4 u-connectXpress v3.0.0 for ANNA-B112
Description
Reference
LE secure connections with security mode 4 incorrectly outputs event +UUBTUPD and accepts AT+UBTUPE.
NOTE: Event +UUBTUPD is replaced with +UUBTUC. Where both AT+UBTUPE and AT+UBTUC can be used for acceptance. For more information and example of configuration see u-connectXpress User Guide [3].
UCS_DEV-676 The command to read multiple GATT characteristics (AT+UBTGRM) is not functional and returns an error response.
This limitation has been found to be incorrectly reported as a known limitation. The command is defined only for client.
TE_NINA_NRF_FW-254 UCS_DEV-30
The disconnect command (AT+UDCPC=1) is not functional until reception of the confirm event of the connect command. The workaround is to wait for the connection confirmation before sending the disconnect command.
TE_NINA_NRF_FW-284 UCS_DEV-142
2 New features
u-connectXpress v3.0.0 for ANNA-B112 has all the features of previous software releases, plus improvements and new features such as the main ones described below. For more information about using these features, see the Using u-connectXpress software UserGuide [3] and the u-connect AT commands manual [4].
2.1 Multiple central support
Connections from up to 6 centrals (for example mobile phones) can be accepted and handled simultaneously in peripheral role and up to 4 centrals in combined central/peripheral role. For more information and example of configuration see u-connectXpress User Guide [3] and the AT command AT+UBTCFG.
2.2 Connection status information
It is now possible to read out all active connections and detailed information about each connection, such as connection interval, slave latency, supervision timeout, MTU size, PDU payload length, role, and more. For further details, see the AT command AT+UBTLELIST and AT+UBTLESTAT.
2.3 Changeable MAC address
It is now possible to change the factory programmed MAC address to a customer defined one. For further details, see the AT command AT+UMLA.
2.4 Configurable reconnect timer
It is now possible to configure the reconnect timeout interval for a connection which is using
connection scheme “always connected”. For further details, see the AT command AT+UDDRP
and the new optional parameter <ac-to>.
3 Notes and limitations
3.1 Solved limitations
UBX-20031225 3/4 u-connectXpress v3.0.0 for ANNA-B112
Description
Reference
In EDM mode, when a central node connects to a remote peripheral device, the wrong frame size is reported in the EDM Connect Event (0x0011). To get the correct size, use the Resend Connect Events (0x0056) command.
TE_NINA_NRF_FW-531 UCS_DEV-185
The un-bond command (AT+UBTUB) is not functional until reception of the confirm event of the bonding command. The workaround is to wait for the bonding confirmation before sending the un-bond command.
TE_NINA_NRF_FW-677 UCS_DEV-77
The response to "Maximum allowed output power" (AT+UBTCFG param_tag 4) is the unsigned representation of the configured value.
TE_NINA_NRF_FW-748 UCS_DEV-78
When going from Discoverable mode to Not Discoverable (AT+UBTDM), and then back, the Scan Response data is cleared.
UCS_DEV-176
Extended advertisement (AT+UBTAD) should support up to 252 bytes of data but is limited to maximum 232 bytes of data.
UCS_DEV-79
The module resets when extended advertisements are disabled after enabling them (AT+UBTLECFG parameter tag 29).
UCS_DEV-83
The minimum value for the Connect linkloss timeout (AT+UBTLECFG parameter tag
7) is 100 ms, but setting any value <110 makes the module hang on store and restart.
UCS_DEV-174
It is not possible to switch to EDM after establishing a Bluetooth low energy connection. No data can be transferred. The workaround is to first switch to EDM, and then establish the Bluetooth low energy connection.
UCS_DEV-175 Not possible to send notifications longer than 20 bytes when setting MTU size 247 (AT+UBTGSN).
UCS_DEV-227
Description
Reference
When using the external pairing functionality (pairing using SWITCH_0, see AT+UBTSM), the LED flashes orange (GPIO pins for red and green LEDs are active) for 60 seconds even after successful bond.
TE_NINA_NRF_FW-426 UCS_DEV-29
The command to discover all characteristic descriptors (AT+UBTGDCD) is missing the response event when using 128 bit UUIDs.
TE_NINA_NRF_FW-910 Possible SPS data loss when L2CAP fragments are small (3 bytes)
UCS_DEV-909
3.2 Known limitations
UBX-20031225 4/4 u-connectXpress v3.0.0 for ANNA-B112
Loading...