u-blox EVK-R5 User Manual

UBX-19042592 - R07 C1-Public www.u-blox.com
EVK-R5
SARA-R5 series cellular evaluation kits
User guide
Abstract
This guide explains how to set up the EVK-R5 evaluation kits to begin evaluating the u-blox SARA-R5 series modules supporting multi-band LTE-M / NB-IoT cellular radio access technology and the u-blox’s leading GNSS technology.
EVK-R5 - User guide
UBX-19042592 - R07 Document information Page 2 of 23 C1-Public

Document information

Title
EVK-R5
Subtitle
SARA-R5 series cellular evaluation kits
Document type
User guide
Document number
UBX-19042592
Revision and date
R07
22-Dec-2020
Disclosure restriction
C1-Public
Product status
Corresponding content status
Functional sample
Draft
For functional testing. Revised and supplementary data will be published later.
In development / Prototype
Objective specification
Target values. Revised and supplementary data will be published later.
Engineering sample
Advance information
Data based on early testing. Revised and supplementary data will be published later.
Initial production
Early production information
Data from product verification. Revised and supplementary data may be published later.
Mass production / End of life
Production information
Document contains the final product specification.
This document applies to the following products:
Product name
Type number
Modem version
Application version
PCN reference
Product status
EVK-R500S
EVK-R500S-0-00
02.06
A00.01
UBX-20053099
Initial production
EVK-R510S
EVK-R510S-0-00
02.06
A00.01
UBX-20053099
Initial production
EVK-R510M8S
EVK-R510M8S-0-00
02.06
A00.01
UBX-20053099
Initial production
u-blox or third parties may hold intellectual property rights in the products, names, logos and designs included in this document. Copying, reproduction, modification or disclosure to third parties of this document or any part thereof is only permitted with the express written permission of u-blox. The information contained herein is provided “as is” and u-blox assumes no liability for its use. No warranty, either express or implied, is given, including but not limited to, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by u-blox at any time without notice. For the most recent documents, visit www.u-blox.com. Copyright © u-blox AG.
EVK-R5 - User guide
UBX-19042592 - R07 Contents Page 3 of 23 C1-Public

Contents

Document information ................................................................................................................................ 2
Contents .......................................................................................................................................................... 3
1 Starting up ............................................................................................................................................... 4
1.1 Overview ........................................................................................................................................................ 4
1.2 Block diagram .............................................................................................................................................. 5
1.3 Switches, jumpers and buttons ............................................................................................................... 6
1.4 LEDs ............................................................................................................................................................... 7
1.5 Connectors ................................................................................................................................................... 8
1.6 Pin out ............................................................................................................................................................ 9
1.7 Board setup ................................................................................................................................................. 11
Appendix ........................................................................................................................................................ 13
A Setting up AT terminal communication ....................................................................................... 13
B Setting up cellular packet data connection on Windows ....................................................... 14
B.1 Install a new modem from the control panel ....................................................................................... 14
B.2 Configuring a new connection ................................................................................................................ 16
C AT commands examples ................................................................................................................... 17
C.1 Define the initial default bearer for connectivity ................................................................................. 17
C.2 Data connection using internal TCP/IP stack ...................................................................................... 17
C.3 Opening a TCP socket .............................................................................................................................. 18
C.4 Opening a UDP socket .............................................................................................................................. 19
D Current consumption measurement ............................................................................................ 20
E Declaration of conformities............................................................................................................. 20
F Glossary .................................................................................................................................................. 21
Related documents .................................................................................................................................... 22
Revision history ........................................................................................................................................... 22
Contact .......................................................................................................................................................... 23
EVK-R5 - User guide
UBX-19042592 - R07 Starting up Page 4 of 23 C1-Public

1 Starting up

1.1 Overview

The EVK-R5 kit is a powerful and easy-to-use tool that simplifies the evaluation of the u-blox SARA-R5 series LTE-M / NB-IoT cellular modules.
The following evaluation kits are available with u-blox SARA-R5 cellular modules:
EVK-R500S evaluation kit is for evaluation of SARA-R500S modules
EVK-R510S evaluation kit is for evaluation of SARA-R510S modules
EVK-R510M8S evaluation kit is for evaluation of SARA-R510M8S modules
All the evaluation kits are identified herein as the EVK-R5.
SIM card holder
J300
Cellular reset
SW303
Cellular power-on
SW302
GND
9 – 1 8 V
Power input
J400
Cellular
adapter board
DL400
Main power switch
SW400
DL401
SARA-R5
cellular module
DIL B2B connector
J300
DIL B2B connector
J301
GND
GNSS antenna
connector
(RF_IN)
J208
GNSS module
GNSS
adapter board
Cellular VCC
supply jumper
J404
Cellular USB
(Single UART)
J501
Cellular RS232
(Single UART)
J500
DL501
DL403
DL405
GNSS USB
J1 02
SW403
SW401
DL404
SW300
SW304
SW204
DS1 32
DS1 1
8
DS1 2
4
DS1 21
DS1 07 DS1 05 DS1 09
DS1 03
DS500 DS501
GND
GND
BT200
Cellular native USB
J1 05
DS1 00
DS201
DS202
Cellular antenna connector (ANT)
J1 06
GNSS antenna
connector (GNSS)
J1 1 2
Cellular USB (Two UARTs)
J201
Cellular VCC
supply jumper
J1 09
Figure 1: Overview of EVK-R5 evaluation kit for SARA-R5 modules
See the SARA-R5 series data sheet [2] and the SARA-R5 series system integration manual [3] for
the features supported by SARA-R5 series modules.
EVK-R5 - User guide
UBX-19042592 - R07 Starting up Page 5 of 23 C1-Public

1.2 Block diagram

Figure 2 shows the main interfaces and internal connections of the EVK-R5 evaluation kit:
SIM
card holder
(J300)
Reset
(SW303)
Power-on
(SW302)
SARA-R5 adapter board
SARA-R5
cellular module
42-pin DIL B2B connector (
J300)
42-pin DIL B2B connector
(J301)
EVB-WL3
GNSS
module
GNSS adapter board
RF_IN
USB
UART
converter
Cellular USB
(single UART)
(J501)
Cellular RS232
(single UART)
(J500)
RS232
UART
converter
UART
MiniUSB/DB9
switch
(SW403)
On-board/B2B
switch
(SW401)
USB
I2C
Step - down
Main power switch
(SW400)
12 V
(J400)
3.8 V
VCC jumper
(J404)
LDO
GPIO2/3/4
GNSS switch
(SW304)
Native
USB
(J105)
CEL ANT
(J106)
Cellular USB
(two UARTs)
(J201)
GNSS
ANT
(J112)
USB
UART
converter
VCC jumper
(J109)
Figure 2: Block diagram of the EVK-R5 for SARA-R5 modules
The EVK-R5 evaluation kit is formed by three boards:
1. The lower one, called EVB-WL3, contains the power supply and other peripherals for the u-blox
SARA-R5 series cellular module (such as SIM card holder, reset button and power-on button).
2. The cellular adapter board, called ADP-R5, contains the u-blox SARA-R5 cellular module, antenna
connectors for the cellular RF interface and the GNSS RF interface1 of the SARA-R5 module, USB connectors for the two UART interfaces and the USB interface of the SARA-R5 module, and the DIL header connectors (J300 and J301) making the interfaces of the SARA-R5 module accessible.
3. The GNSS adapter board, called ADP-GNSS, contains the u-blox GNSS module, the GNSS
antenna connector and the USB connector for the GNSS module.
The cellular and the GNSS adapter boards are connected by means of male header board-to-board connectors provided on the bottom of the adapter boards and their corresponding female connectors provided on top of the lower board, called EVB-WL3.
If the on-board / B2B switch (SW401) is set to “on-board”, then the single UART interface (with the default USIO variant 0 setting, or the USIO variant 1 setting) is available on DIL connectors on the cellular adapter board. It is routed up to the RS232 DB9 connector (J500) or the USB connector (J501) mounted on the EVB-WL3 board according to the settings of the mini-USB / DB9 switch (SW403).
If the on-board / B2B switch (SW401) is set to “B2B”, then the two UART interfaces (with the +USIO variant 2, 3 or 4 setting) are available on the USB connector (J201) mounted on the cellular adapter board.
The USB interface of the cellular module (available for diagnostic purpose only) is available on the native USB connector (J105) mounted on the cellular adapter board.
Other SARA-R5 series peripherals are available on the dual-in-line male board-to-board connectors provided on the top layer of the cellular adapter board (J300 and J301), which are pin-to-pin compatible with the connectors on the bottom layer of the adapter board.
1
EVK-R510M8S only.
EVK-R5 - User guide
UBX-19042592 - R07 Starting up Page 6 of 23 C1-Public
The lower board (EVB-WL3) is also designed to be used with other u-blox cellular adapter boards. It contains additional switches, jumpers, connectors, LEDs and parts that may be only partially described in Figure 1 or in this document, because they are intended for use only with other u-blox cellular modules. It is recommended to leave any additional connector unconnected and any additional switch in its default configuration.

1.3 Switches, jumpers and buttons

Function
Description
Name
Board
Main power switch
Power on / off of the whole evaluation kit
SW400
EVB-WL3
Cellular VCC jumper
Jumper socket to provide the 3.8 V supply to the cellular module VCC input
J404
EVB-WL3
J109
ADP-R5
Cellular power on
Push button to switch on / off the cellular module
SW302
EVB-WL3
Cellular reset
Push button to reset the cellular module
SW303
EVB-WL3
Cellular UART detach
Slide switch to attach / detach the cellular module single UART from the USB / RS232 connectors on EVB-WL3
SW401
EVB-WL3
Cellular UART routing
Slide switch to select cellular module single UART routing on the USB or RS232 connector on EVB-WL3
SW403
EVB-WL3
Cellular GPIO detach
Slide switch to attach / detach the cellular module GPIOs from peripherals: when detached, the signals are available only on the DIL B2B connector on the ADP board
SW300
EVB-WL3
Cellular GNSS detach 2
Slide switch to attach / detach the cellular module to / from the GNSS module (GPIO2-3-4): when detached, the signals are available only on the DIL B2B connector on the ADP board
SW304
EVB-WL3 GNSS V_BCKP
Slide switch to connect / disconnect backup battery to / from the V_BCKP pin of the GNSS module
SW204
EVB-WL3
Table 1: EVK-R5 switch and button descriptions
2
For EVK-R510M8S it is recommended to keep this switch in “detach” position.
EVK-R5 - User guide
UBX-19042592 - R07 Starting up Page 7 of 23 C1-Public

1.4 LEDs

Function
Description
LED #
Board
Color
Main power
Power supply plugged in the 9 - 18 V Power Input
DL401
EVB-WL3
Cellular VCC
Cellular module supplied. Main power switch must be switched on.
DL400
EVB-WL3
Cellular USB (single UART)
USB cable plugged in the Cellular USB connector (J501) for access to the cellular single UART interface (with default USIO variant 0, or USIO variant 1)
DL501
EVB-WL3
Cellular USB (single UART)
Green light is activated when the SW401 is in “on-board” position, and the cellular single UART interface (with default USIO variant 0, or USIO variant 1) is routed to the Cellular USB connector (J501). Red light blinks at TX or RX data on the Cellular USB connector.
DL403
EVB-WL3 Cellular single UART
attach/detach
Green light is activated when the signals of the cellular single UART interface (with default USIO variant 0, or variant 1) are available on the USB / RS232 connectors (J500 / J501) on the EVB-WL3
DL404
EVB-WL3
Cellular RS232 (single UART)
Green light is activated when the cellular single UART interface (with default USIO variant 0, or USIO variant 1) is routed to the Cellular RS232 connector (J500).
Red light blinks at TX or RX data on the Cellular RS232 connector.
DL405
EVB-WL3
Cellular RI indicator
RI line turns ON (active low)
DS501
EVB-WL3
Cellular CTS indicator
CTS line turns ON (active low)
DS500
EVB-WL3
Cellular GPIO1 indicator
Green light is activated when cellular GPIO1 is high
DS107
EVB-WL3
Cellular GPIO2 indicator
Green light is activated when cellular GPIO2 is high
DS105
EVB-WL3
Cellular GPIO3 indicator
Green light is activated when cellular GPIO3 is high
DS109
EVB-WL3
Cellular GPIO4 indicator
Green light is activated when cellular GPIO4 is high
DS103
EVB-WL3
Cellular native USB
USB cable plugged in the Cellular native USB connector on the ADP-R5, for access to the cellular USB interface
DS100
ADP-R5
Cellular USB (two UARTs)
USB cable plugged in the Cellular USB connector (J201) on the ADP-R5, for access to the two UART interfaces (USIO variant 2, 3 or 4)
DS201
ADP-R5
Cellular two UARTs attach/detach
Green light is activated when the SW401 is on the B2B position at module’s boot, and the two UART interfaces (with USIO variant 2, 3 or
4) are routed to the Cellular USB connector (J201) on the ADP-R5
DS202
ADP-R5
GNSS VCC supply
GNSS module supply is turned on
DS118
ADP-GNSS
GNSS USB
USB cable plugged into the GNSS USB connector
DS124
ADP-GNSS
GNSS timepulse
Pulses at 1 Hz when valid GNSS fix
DS121
ADP-GNSS
Cellular / GNSS I2C
Cellular / GNSS module communication over the I2C interface
DS132
ADP-GNSS
Table 2: EVK-R5 LED descriptions
Loading...