Ubert KT 700, KT 1100, KT 700 DB, KT 1400, KT 1100 DB User Manual

...
Page 1
User Manual
COLD DISPLAY CABINET
KT-Series
Page 2
Page 3
Contents 3
1 Contents
1 Contents ................................................................................................................................... 3
2 Important References................................................................................................................ 4
2.1 Fundamental Safety Notes ................................................................................................. 4
2.2 Warranty and Liabilities ...................................................................................................... 5
2.3 Symbols and Notes ............................................................................................................ 5
2.4 Copyright ............................................................................................................................ 5
2.5 Special safety references ................................................................................................... 6
3 Introduction ............................................................................................................................... 8
3.1 Introduction ......................................................................................................................... 8
3.2 Special features .................................................................................................................. 8
3.3 Technical details ................................................................................................................. 9
4 Installation and putting into operation ...................................................................................... 13
4.1 Unwrapping ...................................................................................................................... 13
4.2 Installation ........................................................................................................................ 13
4.3 Electrical connection ......................................................................................................... 13
4.4 Preparation of Using / Starting up ..................................................................................... 14
5 Operation ................................................................................................................................ 15
5.1 Operation elements .......................................................................................................... 15
5.2 Operate ............................................................................................................................ 15
5.3 Operation.......................................................................................................................... 16
5.4 Operate the Timer (UL-version only) ................................................................................. 16
6 Maintenance ........................................................................................................................... 17
6.1 Cleaning and care ............................................................................................................ 17
6.2 Trouble shooting ............................................................................................................... 19
6.3 Wiring Diagrams ............................................................................................................... 20
6.4 Spare Parts ...................................................................................................................... 26
6.5 Declaratoin Of Conformity ................................................................................................ 30
Page 4
4 Important References
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
2 Important References
2.1 Fundamental Safety Notes
2.1.1 Consider notes in the operating manual
Precondition for the safe and trouble free use of this unit is the knowledge of the fundamental safety notes and safety regulations. The operating instruction contains the most important references to operate the unit safely. This operating instruction, particularly the safety references, are to be considered by all persons, who work on the unit. Furthermore the rules and regulations to avoid accidents are to be considered.
2.1.2 Obligation of the operator
The Operator is obliged to only let persons work with the unit who:
are familiar with the fundamental regulations of work safety and accident avoiding and who have
been instructed how to operate the unit.
read and understood the chapter about safety and warning notes and have confirmed this with
their signature.
The safe consious operation of the personnel has to be examined regularly.
2.1.3 Obligation of the personnel
All induviduals who are authorized to work with the unit are obliged to:
pay attention to the fundamental regulations of work safety and accident avoiding, read the chapter on work safety and warning notes in this manual and to confirm through their
signature that they have understood these, before actually operating the unit.
2.1.4 Possible risks
Cold Display Cabinets are built state of the art and in acknowledgement of all safety related rules. Nevertheless is it possible that danger for body and lifes of the user and/or third and/or impairments at the unit or at other real values merge. The unit is to be used only :
for the due use. in safety related flawless condition.
Disturbances which can hurt the safety are to be eliminated immediately.
2.1.5 Due use
The Cold Display Cabinets are built exclusively for the cooling of food only. Any other use of the unit are only allowed after consulting UBERT GASTROTECHNIK GMBH. Damages which result out of wrong use UBERT GASTROTECHNIK GMBH cannot be held responsible. Part of the due use is also:
the consideration of all references of the operating manual and the observance of neccessary maintenance and service.
Page 5
Important References 5
2.2 Warranty and Liabilities
Fundamentaly our "General terms of sale and delivery" count. These are known to the operator at the latest since signing of the contract. Claims to warranty and liability at persons- and property damages are impossible, if they are to be led back to one or serveral of the following causes:
Non due use of the unit. Improper assembling, starting up, operating and servicing of the unit. Operating the unit with defective safety devices or safety devices which have not been installed
properly and are in no working condition.
Disobeyment of the references in the operating manual concerning transportation storage, instal-
lation, start-up, operation, maintenance and assembling of the unit.
Unauthorized mechanical or electrical changes of the unit. Unsufficient maintenance of wear and tear parts. Unauthorized repair. Force of nature and act of god.
2.3 Symbols and Notes
In the operating manual the following symbols and signs are used:
This symbol means a possibly or directly threatening danger for the life and the health of persons and/or a possibly dangerous situation.
Ignoring of these references may result in consequences for your health and/or can lead to property damages !
This symbol points to important references for the proper use of the unit.
Not paying attention to these references can lead to disturbances at the unit or in the environment !
This symbol points to operation tips and especially useful information.
Help to use all functions at your unit optimally
2.4 Copyright
The copyright on this operating manual remains at the company UBERT GASTROTECHNIK GMBH This operating manual is intended only for the operator and his personal. It contains instructions and references wich neither completely nor partially:
be duplicated be circulated or be otherwise made available to third parties.
Offences may violate applicable laws.
Page 6
6 Important References
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
2.5 Special safety references
2.5.1 Safety devices
Before operating the unit all protective devices as well as all removable parts must
be installed correctly and be fully workable.
Protective devices may only be removed:
after stand still and prevention of unintentional restart. If partial components are delivered, an authorized staff member or service tech-
nician has to execute assembly according to installation guidelines.
2.5.2 Informal safety steps
The operating manual is to be kept constantly accessible in the operating area. In addition to the operating manual all generally acknowledged and all local regula-
tions for accident avoiding and environmental protection have to be applied with.
All safety- danger labels at the unit are to be kept in readable condition.
2.5.3 Education of the personal
Only trained and instructed personal may work at the unit. The responsibilities of the personal are to be determined clearly for installing, start-
up, operation, assembling, and servicing of the unit.
During instruction the personal may only work at the unit under supervision of an
experienced person.
2.5.4 Unit-control
Only instructed personal is allowed to operate the controls.
2.5.5 Safety during regular operation
The unit is only to operate if all protective devices are fully workable. At least once per shift the unit is to be examined with regard to visible damages and
functional ability of the safety devices.
2.5.6 Dangers caused by electric energy
Any work on the electrical supply is to be executed only by a specialist. Likewise the electrical connection of this unit to the power supply must be executed
by an electro-specialist; the connection must follow the rules of the local determina­tions.
The electric installation is to be examined regularely. Loose connections and brased
cabels are to be eliminated immediately.
If works at any life-parts are necessary, a second person who switches off the main
switch if neccessary is to consult.
2.5.7 Special danger-spots
Do not touch the cooling plant if the unit is switched on!
Do not touch the evaporator!
Page 7
Important References 7
2.5.8 Service and maintenance, troubleshooting
Prescribed adjustment, service and inspection work is to be accomplished timely by
the manager or if necessary by an authorized service technician.
The operating personal is to be informed before the beginning of the maintenance
and service work.
The unit is to be disconnected from the mains before maintaining, inspecting and
repairing is performed; the main switch is to be guarded against unintended reclos­ing.
Check all screw connections for tight fitting. After finishing maintenance check all safety devices for proper functionality.
2.5.9 Structural changes to the unit
Do not perform any changes, extensions or conversions to the unit without the manu-
facturers permission, especially welding work at supporting parts.
For all conversions a written permission of the company UBERT GASTROTECHNIK
GMBH is necessary.
Change all parts of the unit, that are in impropper condition. Use only original spare parts.
2.5.10 Cleaning of the unit and disposal of the waste
Used substances and materials are to be handled and disposed appropriately, especially lubricants. Detergents have to follow the rules of food-hygiene.
Page 8
8 Introduction
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
3 Introduction
3.1 Introduction
All Cold Display Cabinets are synonymous in construction and therefore you will have the possibility of an optimum integration in a com­plete display conception. An adjustable tem­perature control enables you to set the desired cooling temperature. We guarantee a constant temperature even in case of opened doors. The temperature rises only after some minutes. The Cold Display Cabinets show a high cooling performance. Within the Cold Display Cabinets, the cooling convection pro­vides a stable temperature. The set tempera­tures are reached within one hour, the degree of condensation is low.
The maximum holding time depends on the kind of product and on the products starting temperature. It might be limited by national or local regulations. Never equip the cabinet with warm or hot products.
3.2 Special features
Ergonomic, stylish design
Maximum product visibility by curved front glass
Optically doubled foodpresentation by mirrored sliding doors
All models are available as self-service equipment for impulse buying
Page 9
Introduction 9
3.3 Technical details
3.3.1 Dimensions [mm]
KT 700 / KT 700 DB:
Page 10
10 Introduction
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
KT 1100 / KT 1100 DB:
Page 11
Introduction 11
KT 1400 / KT 1400 DB:
Page 12
12 Introduction
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
3.3.2 Weight
Type weight [kg] KT 700 70
KT 1100 94
KT 1400 116
KT 700 DB 70
KT 1100 DB 94
KT 1400 DB 116
3.3.3 Electrical details
Type electrical connection (EA) power
KT 700 230V, 1/N, 50Hz 0.31 kW
KT 1100 230V, 1/N, 50Hz 0.42 kW
KT 1400 230V, 1/N, 50Hz 0.44 kW
KT 700 DB 230V, 1/N, 50Hz 0,33 kW
KT 1100 DB 230V, 1/N, 50Hz 0,45 kW
KT 1400 DB 230V, 1/N, 50Hz 0,47 kW
KT 700-2 120V, 1/N, 50Hz 0.21 kW
KT 1100-2 120V, 1/N, 50Hz 0.33 kW
KT 1400-2 120V, 1/N, 50Hz 0.34 kW
KT 700-2 DB 120V, 1/N, 50Hz 0.21 kW
KT 1100-2 DB 120V, 1/N, 50Hz 0.33 kW
KT 1400-2 DB 120V, 1/N, 50Hz 0.34 kW
3.3.4 Noise emission
Type noise emission
all types < 70 dB (A)
3.3.5 Refrigeration medium
Refrigeration medium for all Cold Display Cabinets: R 134 A
Page 13
Installation and putting into operation 13
4 Installation and putting into operation
In general all Cold Display Cabinets will be packed for safe transport after the final control in order to reach you properly. Nevertheless we ask you to have a look at the machine on arrival to detect any transport damages if there are any.
Note! Visible damages have to be reported immediately!
4.1 Unwrapping
Open the carton and take out the wrapping material carefully.
Take care that the delivery is complete (see attached freight papers).
4.2 Installation
Place the cabinet in the desired location. Make sure, that is is good visible for your customer to ensure good foodpresentation and successfull sales. Take care of the following points:
Place the Cabinet dry. Take care that the Cabinet has to be placed in well ventilated rooms! Mounted in
a cut out of a counter with air openings (min. air inlet opening of 419,1mm by 215,9mm and discharge opening of 482,6 by 228,6mm). Fitted with silicon all around the cabinet.
Avoid to place the cabinet close to any heat-sources (heaters, radiators, sun-
beams and the like).
The cooling compartment (condenser and compressor) below the cabinet must be
well ventilated after installation.
The cabinet (with or without stand) has to be placed on a horizontal level. Use a
spirit level if necessary.
Take care that both sides have at least 10cm clear space to enable cleaning of
the sideglasses.
There has to be enough free space to load, unload, clean and maintain the unit. The machine has to be placed so that the complete area around it can be cleaned
easily.
4.3 Electrical connection
Note! In general, only service technicians of the company: UBERT GASTRO-
TECHNIK GMBH or service technicians of your responsible service partner are al­lowed to perform el. connection and other service! All national and lokal rules and regulations concerning electricity, fireprotection and the like have to be concidered. During any servicing, take care that the unit is disconnected from the mains! Not pay­ing attention may result in injury!
Please learn the electrical and technical data of your unit from the nameplate.
Check whether your lokal electrical power supply is in accordance with the values on the name
plate.
The power supply needs to be manufactured from heat resistant, flexible cable. It is to be routed
to prevent any contact to hot parts.
The unit is to be connected to the power supply either by means of an appropriate plug or if con-
nected permanently, a switch (interupting all poles) is to be provided. In case of an emergancy the power supply must be interuptable immediately.
For further information please see the wiring diagram (below).
Note!
After finishing any installationwork, maintainance or repair check whether the ground wires are connected properly to the casing.
Page 14
14 Installation and putting into operation
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
4.4 Preparation of Using / Starting up
Note! To ensure compensation of refrigerant, keep the unit switched off at least two
hours after installation. After transporting (moving) the unit in an upright position wait at least 30 minutes before restart..
Before operating the Cold Display Cabinet you have to clean the unit and all removable parts (e. g. GN-basins) carefully with a grease solvent. Afterwards you have to dry all surfaces.
Note! Do not use flammable cleaners. Do not use high-pressure-, water pressure- or steam jet- cleaning machines. You will have further information about this in the sec­tion ”cleaning and upkeeping”.
After cleaning the Cabinet properly the smell will be minimal when using it the first time.
Page 15
Operation 15
5 Operation
Following you will find explanation and location of all components and their function for the use of the cabinet.
5.1 Operation elements
Control panel
The control panel with switches for illumination and fan as well as temperature control is located un­derneath the stainless steel cover.
5.2 Operate
Switch - Fan:
This switch activates the fan which responsible for convection. The fan is activated when the light in the switch is illuminated.
Note! With each start of the unit first the fan has to be started before the cooling aggregate works. The design and safety feature ensures convection and prevents possible damaging of the unit.
Control panel
thermometer
temperature control
switch - lighting
switch - fan
Page 16
16 Operation
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
Switch - lighting:
The lighting of the unit supports efficient illumination of the unit and ensures product presentation at its best. The lights are activated when the light in the switch is illuminated.
Temperature control:
With the temperature control switch you can choose the desired cool­ingpower. 1 equals the minimum , 7 equals the maximum cooling pow­er.
GN - pan
Stuffing just 4 inch (max.)!
5.3 Operation
Cutting Board:
To cut your products and do various other work during loading, unload­ing packing an the like.
Motive-Sets:
The Motive-Sets are sales promoting picture sets for the Dia­Menueboard.
Intermediate Shelf:
The Intermediate Shelf is located above the GN-pans for additional storage space.
Timer (only UL-version):
The timer is left next to the switches for the illumination and the fan. The cycles can be programmed free and it can be set any time.
5.4 Operate the Timer (UL-version only)
You program the timer by the tabs.  The figures on the scale are synonymous for the time.  The time can be switched in half hour steps (one tab = an half hour).  Pull all the tabs continuosly towards you, that are in the periode, the Cold
Display Cabinet should be swtiched on (tab pulled out = unit s witched on / tab pushed in = unit switched off).
Now adjust the present time by turning the scale in arrow direction as far
as the corresponding figure is above on the scale, in front of the mark that is on the ring behind.
Now the Timer is programed.
This program repeats daily until you change it.
Page 17
Maintenance 17
6 Maintenance
Following we will show you some advices concerning maintenance, care, trouble shooting and se r­vice for your Cold Display Cabinet.
6.1 Cleaning and care
6.1.1 Safety advices
Before you start to clean and care switch off the appliance and disconnect it from
the mains.
Do not use inflammable detergents, sharp-edged or metallic things for cleaning
the unit! Never use high-pressure-, water pressure- or steam jet- cleaning ma­chines!
Wear acidproof gloves while cleaning the parts to prevent skin irritations.
6.1.2 General Recommendations
The unit has to be cleaned daily.
Only use cleaners that are appropriate for food (neutral or alkaline detergents),
even if there are plain and persistent residues.
After cleaning with special cleaners you have to wash all parts with clear water
and dry them afterwards so that there are no residues of the cleaner on these parts.
It is absolutely necessary to watch out for some fundamental things to keep this
longliving high-grade-steel-machine working:
- always keep the high-grade-steel surface clean.
- watch out that there is always enough fresh air on the surface
- never contact the surface with rusty material
never use bleaching or chlorine cleaners.
Take brushes with plastic or natural bristles for cleaning.
6.1.3 Detergents
To make the cleaning fast and easy we have integrated some cleaners in our pro­gram:
Grill- and ovencleaner:
To dispose persistend, dried-up dirt on metal surfaces.
Intensiv-cleaner:
Detergent for metal- and plastic-surfaces.
Glass-cleaner:
Removes fat from glass-surfaces.
Stainless-steel-cleaner
You have to spray this from a distance of app. 25 cm on the surface and wipe it off with a dry cleaning rag. If you want to clean only small parts you have to spray it directly on the cleaning rag and wipe it off this way. With this method it is possi­ble to clean the Cold Display Cabinet easily and without stripes.
Page 18
18 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.1.4 Special cleaning hints
Please find below some special cleaning tips for this specific unit:
Lamps:
To be cleaned only with soft paper or cloth and alcohol.
Glass:
Lift the cuved front glass to clean the inside. Remove dust and dirt from the glass surface with soft cloth to avoid scratches.
Drawers, GN-Pans:
Easily removable without tools for separate cleaning.
Air openings, evaporator:
All air openings as well as the evaporator need to be cleaned regularly to ensure convection and cooling performance of the unit and also to minimize preventation of dirt particles into the fan and lamina of the evaporator. Damages to the unit can be prevented that way. After removing the GN – pans the cleaning can be effect­ed with a vacuum cleaner or a brush. Be careful to prevent injuries or damage of the unit.
Page 19
Maintenance 19
6.2 Trouble shooting
If your Cold Display Cabinet does not work satisfactorily we would like to give a first help with the following checklist. Only after checking these points you should contact:
a) your responsible service partner
or
b) directly the company: UBERT GASTROTECHNIK GmbH
Werk II Gewerbegebiet Nord Vennekenweg 17 46348 Raesfeld Tel.:(49) 02865 / 602-226 Service-Tel.:0172 / 2 82 86 31 Fax:(49) 02865 / 602-102 (or -103)
Only these two companies are allowed to carry out service work and replacement of defect parts. If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid!
Checklist for your Cold Display Cabinet:
1. Is the unit wired properly and connected to the mains?
2. Does the wall socket provide the required current / voltage (see the nameplate for details)?
3. Does the fuse protection work properly?
4. Does the unit cool properly? Please check power supply and control lamp!
5. Have you possibly stored hot or warm goods?
6. Is the ventilation and deaeration of cooling machine sufficient?
7. Is the evaporator iced?
8. Have you correctly adjusted the thermostat?
9. Is the timer programed properly? (only UL-version!)
10. Do all lamps work properly? Check lamps and connection!
Page 20
20 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.3 Wiring Diagrams
6.3.1 KT 700 230V / 50Hz / 1/N
6.3.2 KT 700 DB 230V / 50Hz / 1/N
Page 21
Maintenance 21
6.3.3 KT 1100 230V / 50Hz / 1/N
6.3.4 KT 1100 DB 230V / 50Hz / 1/N
Page 22
22 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.3.5 KT 1400 230V / 50Hz / 1/N
6.3.6 KT 1400 DB 230V / 50Hz / 1/N
Page 23
Maintenance 23
6.3.7 KT 700-2 (UL) 120V / 50Hz / 1/N
6.3.8 KT 700-2 DB (UL) 120V / 50Hz / 1/N
Page 24
24 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.3.9 KT 1100-2 (UL) 120V / 50Hz / 1/N
6.3.10 KT 1100-2 DB (UL) 120V / 50Hz / 1/N
Page 25
Maintenance 25
6.3.11 KT 1400-2 (UL) 120V / 50Hz / 1/N
6.3.12 KT 1400-2 DB (UL) 120V / 50Hz / 1/N
Page 26
26 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.4 Spare Parts
Defect parts are to be replaced only by original spare parts of UBERT GASTROTECHNIK GMBH; the replacement is to be carried out only by their service personal or by your authorized Service companies. If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid! Also all certifications (CE, UL, NSF and the like) become invalid!
6.4.1 Explosion Diagramm
KT and KT DB are almost the same. The only difference is the part 23. It is the front screen on KT and the Dia-Board on KT DB.
Page 27
Maintenance 27
6.4.2 Spare Parts List KT700 / KT700DB
Pos.
Description
Part No.
Amount
1
front glass
121060
1
2
glass holder for side glass, above
121042
2
3
lamp socket
340103
2
4
ornamental glass
420109
1
5
cover for evaporator
121116
1
6
evaporator
346100
1
7
side glass
420306
2
8
glass support
361113
2
9
door stopper, teflon
361503
4
10
crumb tray
121120
2
11
blower motor
344117
3
12
guide blade (690mm), above
121043
1
13
sliding door left, assy
121063
1
14
sliding door right, assy
121064
1
15
guide blade (660mm), below
121044
1
16
ballast KT 700 / KT 700 DB
340125
1
16
ballast KT 700-2
340630
1
16
ballast KT 700-2DB
340631
1
17
cooling unit KT 700 / KT 700 DB
346104
1
17
cooling unit KT 700-2 / KT 700-2DB
346115
1
18
thermometer -40°C to +40°C KT 700 / KT 700 DB
342908
1
18
thermometer -40°F to +100°F KT 700-2 / KT 700-2DB
342911
1
19
tumber switch
341108
2
20
thermostat -3°C to +12,5°C
342215
1
21
capacitor
340115
1
22
glass holder 15/10/10, below
121065
4
23
frontage Mr. Pick
120519-1
1
23
Dia-Menueboard KT 700 DB
DB700
1
23
Dia-Menueboard KT 700-2DB
341501
1
24
intermediate web
120524
1
25
lamp starter
340101
1
26
socket starter
340117
1
27
fluorescent lamp (15W) KT 700 / KT 700 DB
340110
1/2
27
fluorescent lamp (20W) KT 700-2 / KT 700-2DB
340116
1/2
28
tipping profile, black (730mm)
121046
1
Display
360142
1
Timer KT 700-2 / KT 700-2 DB (optional)
342160
1
KT700
Cold Cabinet Europe-Version
KT700-2
Cold Cabinet UL-Version
KT700DB
Cold Cabinet Europe -Version with Dia-Menueboard
KT700-2DB
Cold Cabinet UL-Version with Dia-Menueboard
Page 28
28 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.4.3 Spare Parts List KT1100 / KT1100DB
Pos.
Description
Part No.
Amount
1
front glass
121061
1
2
glass holder for side glass, above
121042
2
3
lamp socket
340103
2
4
ornamental glass
420110
1
5
cover for evaporator
150017
1
6
evaporator
346107
1
7
side glass
420306
2
8
glass support
361113
2
9
door stopper, teflon
361503
4
10
crumb tray
121120
3
11
blower motor
344117
3
12
guide blade (1000mm), above
121133
1
13
sliding door left, assy
121032
1
14
sliding door right, assy
121033
1
15
guide blade (1000mm), below
121134
1
16
ballast KT 1100 / KT 1100 DB
340127
1
16
ballast KT 1100-2
340632
1
16
ballast KT 1100-2DB
340633
1
17
cooling unit KT 1100 / KT 1100 DB
346105
1
17
cooling unit KT 1100-2 / KT 1100-2DB
346116
1
18
thermometer -40°C to +40°C KT 1100 / KT 1100 DB
342908
1
18
thermometer -40°F to +100°F KT 1100-2 / KT 1100-2DB
342911
1
19
tumber switch
341108
2
20
thermostat -3°C to +12,5°C
342215
1
21
capacitor
340115
1
22
glass holder 15/10/10, below
121065
4
23
frontage Mr. Pick
120551-1
1
23
Dia-Menueboard KT 1100 DB
DB1100
1
23
Dia-Menueboard KT 1100-2 DB
341502
1
24
intermediate web
121132
2
25
lamp starter
340101
1
26
socket starter
340117
1
27
fluorescent lamp (30W)
340112
1
28
tipping profile, black (1070mm)
121127
1
Display
360142
1
Timer KT 1100-2 / KT 1100-2 DB (optional)
342160
1
KT1100
Cold Cabinet Europe-Version
KT1100-2
Cold Cabinet UL-Version
KT1100DB
Cold Cabinet Europe -Version with Dia-Menueboard
KT1100-2DB
Cold Cabinet UL-Version with Dia-Menueboard
Page 29
Maintenance 29
6.4.4 Spare Parts List KT1400 / KT1400DB
Pos.
Description
Part No.
Amount
1
front glass
121062
1
2
glass holder for side glass, above
121042
2
3
lamp socket
340103
2
4
ornamental glass
420111
1
5
cover for evaporator
150027
1
6
evaporator
346108
1
7
side glass
420306
2
8
glass support
361113
3
9
door stopper, teflon
361503
4
10
crumb tray
121120
4
11
blower motor
344117
4
12
guide blade (1370mm), above
121144
1
13
sliding door left, assy
121051
1
14
sliding door right, assy
121052
1
15
guide blade (1338mm), below
121145
1
16
ballast KT 1400 / KT 1400 DB
340128
1
16
ballast KT 1400-2
340632
1
16
ballast KT 1400-2DB
340633
1
17
cooling unit KT 1400 / KT 1400 DB
346106
1
17
cooling unit KT 1400-2 / KT 1400-2DB
346116
1
18
thermometer -40°C to +40°C KT 1400 / KT 1400 DB
342908
1
18
thermometer -40°F to +100°F KT 1400-2 / KT 1400-2DB
342911
1
19
tumber switch
341108
2
20
thermostat -3°C to +12,5°C
342215
1
21
capacitor
340115
1
22
glass holder 15/10/10, below
121065
4
23
frontage Mr. Pick
120581-1
1
23
Dia-Menueboard KT 1400 DB
DB1400
1
23
Dia-Menueboard KT 1400-2 DB
341503
1
24
intermediate web
120596
3
25
lamp starter
340101
1
26
socket starter
340117
1
27
fluorescent lamp (36W) KT 1400 / KT 1400 DB
340113
1/2
27
fluorescent lamp (40W) KT 1400-2 / KT 1400-2DB
340119
1/2
28
tipping profile, black (1410mm)
121139
1
Display
360142
1
Timer KT 1400-2 / KT 1400-2 DB (optional)
342160
1
KT1400
Cold Cabinet Europe-Version
KT1400-2
Cold Cabinet UL-Version
KT1400DB
Cold Cabinet Europe -Version with Dia-Menueboard
KT1400-2DB
Cold Cabinet UL-Version with Dia-Menueboard
Page 30
30 Maintenance
printed: 02/2015 Subject to change! TopLineUserManualKT.docx
6.5 Declaratoin Of Conformity