Tysso PDC2, MPDC User Manual

Install Utility Software
Run Setup.exe from your CD ROM drive and follow the installation instructions accordingly.
Login to PDC2/MPDC
PDC2/MPDC is password protected to prevent unauthorized access to the data stored in the reader. No default password is set at factory. You have the option not to use this login feature at all. Simply press OK when prompted for your password at login.
Download Captured Data to Host PC
Execute the download command from the main menu of the bundled utility. Upon completion of the download operation, a data window will pop up in the foreground of your screen for your review. You can either print it out or save it to a file for further processing.
Download and Configuration Utility
A PDF softcopy of the Operation Guide is contained in the utility CD. Refer to the step-by-step operating procedures to use the utility to interoperate with the reader.
Specifications
PDC2
Processor Memory Capacity Battery Type Track Readability Magnetic Head Life Swipe Speed Standard Compliance Housing Color Dimensions Weight Operating Temperature Storage Temperature Relative Humidity RS-232 Cable Operating System
MPDC
Processor Memory Capacity Battery Type
Track Readability Magnetic Head Life Swipe Speed Standard Compliance Housing Color Dimensions Weight Operating Temperature Storage Temperature Relative Humidity RS-232 Cable Operating System
80C31 8-bit CPU 256KB Flash 9V DC Alkaline disposable Tracks 1&2&3 configurable 300,000 passes minimum 5 to 60 inch/sec bidirectional ISO 7811 ABS Plastic Black 100 mm 33 mm 58 mm 131 grams (with battery) 0to45C
-20 to 70 C 0% to 95% (non-condensing) Stereo plug to DB9F Windows 98, 2000, XP
80C31 8-bit CPU 256KB Flash
3.7V 600 mAh Lithium-Ion rechargeable Tracks 1&2&3 configurable 300,000 passes minimum 5 to 60 inch/sec bidirectional ISO 7811 ABS Plastic Black 53 mm 34 mm 34 mm 51 grams (with battery) 0to45C
-20 to 70 C 0% to 95% (non-condensing) Stereo plug to DB9F Windows 98, 2000, XP
xx
o
o
xx
o
o
PDC2/MPDC
Magstripe Portable
PDC2
Status Indicator
Download Cable Jack
Wakeup Button
MPDC
45
Introduction
Status Indicator(s)
Power on PDC2/MPDC
PDC2/MPDC is a very powerful data collection system ideal for time and attendance tracking in classrooms, trade shows, and conferences. Its key features include:
·
Battery operated - lasts 15,000+ swipes for PDC2 and 30,000+ swipes for MPDC
·
Automatic shutdown for power conservation
·
Data retained even if battery removed
·
LED status indicator(s)
·
Reads tracks 1, 2, and 3
·
Stores 3000 dual track or 1500 triple track swipes
·
Required tracks configurable
·
Only valid swipes are logged
·
All swipes are timestamped
·
Hardware password protection
·
Easy-to-use download and configuration utility
Getting Started
Package Contents
Before getting started, make sure your PDC2/MPDC package includes the following items:
·
PDC2/MPDC main unit
·
PDC2: 9V DC Alkaline disposable battery MPDC: 3.7V 600 mAh Lithium-Ion rechargeable
battery and standalone charger
·
RS-232 download cable
·
Utility CD
·
Single-sheet pamphlet
(The following two paragraphs apply to PDC2 only.)
PDC2 comes equipped with two LEDs. The red LED is primarily for showing status whereas the green LED is for exhibiting status. The red LED blinks every two (2) seconds to indicate the reader is in a ready or active state. It stops blinking when 1) the reader shuts itself off after a predetermined period of inactivity, 2) the power switch is turned off, or 3) the battery completely drains. The green LED comes on momentarily in response to a good swipe. In case of a bad read, the red LED lights up briefly instead.
The green LED will keep blinking while download operation is in progress and switch itself off upon completion. When the internal memory reaches its full capacity, the red LED and the green LED will come on alternately. You must download then erase the captured data at this point in order to resume the reader's operation.
(The following two paragraphs apply to MPDC only.)
MPDC comes equipped with a single dual-color LED. The red color is primarily for showing status whereas the green color is for exhibiting status. The LED blinks red every two (2) seconds to indicate the reader is in a ready or active state. It stops blinking when 1) the reader shuts itself off after a predetermined period of inactivity, 2) the power switch is turned off, or 3) the battery completely drains. The green color comes on momentarily in response to a good swipe. In case of a bad read, the red color lights up briefly instead.
The LED will keep blinking green while download operation is in progress and switch itself off upon completion. When the internal memory reaches its full capacity, the LED will flash red and green alternately. You must download then erase the captured data at this point in order to resume the reader's operation.
power on
data capture
power on
data capture
(The following paragraph applies to PDC2 only.)
Turn the power switch on and the red LED will start blinking. If there is no activity during a predetermined period of time, the reader will turn itself into a "sleep mode" or "inactive mode" and the red LED will stop blinking. Press the wakeup button to reactivate the reader. In order to completely shut off the unit, you will need to turn the power switch off.
(The following paragraph applies to MPDC only.)
Turn the power switch on and the LED will start blinking red. If there is no activity during a predetermined period of time, the reader will turn itself into a "sleep mode" or "inactive mode" and the LED will stop blinking. Press the wakeup button to reactivate the reader. In order to completely shut off the unit, you will need to turn the power switch off.
Real Time Clock (RTC)
A timestamp in the format of YYYY/MM/DD HH:MM:SS is also stored in the reader along with each data entry. You can enable or disable downloading of the timestamps through the bundled utility. Note that the RTC is not initialized at factory. You need to set it up when you use the unit the first time and each time you install a new battery.
Connect PDC2/MPDC to Host PC
Plug the stereo end of the RS-232 cable to PDC2/MPDC and attach the DB9F end to the serial port on your host PC.
1
2
3