Page 19
Faults
7
Faults
Faults Possible cause Solution
Control unit does not run
although the mains cable
is connected
Control unit is switched o X Switch control unit on, see Chapter 4.
Mains cable is defective X Replace the mains cable.
No voltage at the power supply (building site)
X Check the power supply.
Power supply phases incorrectly connected
X Check the power supply.
Phase missing See the chapter «Responding to displays».
The control unit starts and
then switches o again
Building site power supply cut-o unit
trips
X Check and if necessary adapt the cut-o protection.
X If necessary change the power supply.
X See chapter «Responding to displays».
No power, even though
the control unit is running
Incorrect voltage
Defective main motor
X Make sure that the control unit voltage and frequency
match the mains supply specications.
X Contact TYROLIT Hydrostress AG customer service.
The control unit suddenly
switches o
Over or under voltage X Check the power supply. Refer to fault indicator.
Cross section of power supply cable too
small
X Check the power supply.
Defective plug connection X Check the plug connection.
X Check the power supply.
Group alarm X Refer to fault indicator.
Main motor is not running • Main motor potentiometer is in 0-po-
sition
• Defective main motor On / O switch
on remote controller
The remote controller 'ready to operate'
light does not come on.
X Contact TYROLIT Hydrostress AG customer service.
X Do not start control unit, see Chapter 4.2
EMERGENCY STOP activated X Deactivate EMERGENCY STOP, see Chapter 4.10.
Overheating X Check the water circuit and the plug-in couplings.
X Refer to fault indicator.
No water X Switch on the water supply.
X Refer to fault indicator.
Remote controller not
working
Rechargeable battery or battery have
too little charge
X Replace rechargeable battery and recharge or install
cable operation.
X Replace batteries.
Feed potentiometer indicates no function
• Defective potentiometer in the remote
controller
• Feed motors not connected
• Defective feed motor
• Joystick is in the zero position
X Contact TYROLIT Hydrostress AG customer service.
X See Chapters 3.1 / 4.6 / 4.7
Feed motor fails to
build up power
Remote controller potentiometer is defective or in the 0-position
X Contact TYROLIT Hydrostress AG customer service.
X See Chapter 4.7.1
Defective cable X Contact TYROLIT Hydrostress AG customer service.
Motor fault X Contact TYROLIT Hydrostress AG customer service.