INTRODUCTION
The Advent xt printer records the time and date of all calls made/answered/cancelled on the
warden call system. All other system activity such as telephone line fault, mains fail, system reset,
etc. is also recorded.
PUSHBUTTON
The pushbutton performs several functions; click once to turn the printer on, press and hold for
paper feed when changing paper rolls or double-click to perform a self test and print the internal
settings.
LED INDICATOR
The LED indicator on the front of the printer will normally flash short green - long orange, there are
a number of other colour combinations which provide printer status information;
Battery Flat - or printer in sleep modeNo LED
Spool Error ConditionFast Flashing Red
Spool Fast ChargingFast Flashing Orange
Spool Battery LowShort Green - Short Red
NormalBattery LowLong Green - Short Red
Spool Running on BatteryFast Flashing Green
NormalRunning on Battery Steady Green
Spool Trickle ChargingLong Orange Flashing
NormalTrickle ChargingShort Green - Long Orange
Buffer ModeBattery StatusLED Pattern
The printer will enter Spool Mode if the paper runs out, the paper compartment flap is up or an
error has occurred. Data will be buffered for printing when the condition is rectified.
BATTERY STANDBY
If the mains supply is disconnected the LED will be steady green for a preprogrammed time until
the printer enters sleep mode. When the mains supply is restored click the pushbutton to return to
standby mode and any missed calls will be printed.
PRINT-OUT DETAILS
The print-out is designed to give as much information as possible about the status of the system
whilst using the minimum of paper. All alarm call print-outs are restricted to one line of text in the
following format:
Operating
Mode
Time
(24HR)
Date
(DDMM)
Call
Type
Channel
ID
Alarm
Prefix
Example: AL 0001 INTERCM 22/12 14:20 ON
The above example tells you an intercom alarm from flat 1 was detected at 14:20 on 22
December and the system was operating in onsite mode. See below for details of the
abbreviations used;
ALARM PREFIXES
AL Alarm Call SA System Alarm
CA Call Answered SR System Report
CE Call Ended FN Function Start/Finish Time
CB Call Back Start/Finish Time (eg. FN 1000 = All Call)
CALL TYPES
INTERCM Intercom Alarm CO GAS Carbon Monoxide Alarm
PENDANT Pendant Alarm GAS Natural Gas Alarm
PCORD Pullcord Alarm FLOOD Flood Detector Alarm
SMOKE Smoke Alarm LO TEMP Hypothermia Alarm
OPEN CT Open Circuit Fault BED OCC Bed Occupancy Alarm
AL FAULT Intercom Fault (not responding) CL WAND Client Wandering Alarm
INACTIV Inactivity Alarm PILL DS Pill Dispenser Alarm
INTRUDR Intruder Alarm ENURES Enuresis Alarm
PARKED Intercom Parked
SYSTEM ALARMS (SA)
4797 BT FLT Telephone Line Fault 3999 FIRE AL Fire Alarm Activated
4796 BT OK Telephone Line Restored 4800 NTR FLT Network Receiver Fault (ID 800-815)
4799 MAIN FL Mains Failed 4816 NEI FLT Network PBX I/F Fault (ID 816-823)
4798 MAIN OK Mains Restored 4824 NKS FLT Network Keyswitch Fault (ID 824-827)
4793 LOW BT Low Battery
4794 FUSE BL Low Voltage Fuse Blown
SYSTEM REPORTS (SR)
CARE CL Extracare Call Cancelled DIAL TELE 01 Dial Telephone Number 01
SYSTEM RESET System Reset BT LINE DROP Telephone Line Dropped
RING DETECT Telephone Line Ring Detected
BT LINE SEIZ Telephone Line Seized SUB PRIVACY Intercoms with Privacy On
OPERATING MODES
ON Onsite Mode
LO Local Offsite Mode
RO Remote Offsite Mode
DOOR ENTRY
DE 0032 DOOR 01 Flat 32 Called From Door Panel 1
DE DOOR OPEN 01 Door Entry Opened Door 1
TEL TRANS EN 0001 TO 0002 Flat 1 Door Entry Telephone Calls Transferred to Flat 2
TEL TRANS EN 0001 Confirm Flat 1 Door Entry Telephone Calls are Transferred
CALL TRANS EN 0008 24 Hour Calling Enabled for Flat 8
CALL TRANS DIS 0008 24 Hour Calling Disabled for Flat 8
TEL PRIVACY 0015 Flat 15 Door Entry Telephone has Privacy ON
TEL FAULT 0020 Flat 20 Door Entry Telephone has a Fault
Note: to conserve paper all door entry related print-outs can be disabled via the Advent xt “Door Entry Setup” webpage.