Tyloheloinc 1517-17-02, 1517-22-02, 1517-30-02 Installation Manual

INSTALLATION AND OPERATING INSTRUCTIONS
SL2
(SaunaLogic 2)
(1601-38)
CB Box
(1201-13-1 or
1201-16-1)
"Junior" Sauna Heater Series Models
1.7, 2.2, 3.0 (1517-17-02, 1517-22-02, 1517-30-02) with SL2 (SaunaLogic 2) Control (1601-38)
Read all instructions carefully before installation. Please leave all instructions and warranty with the owner.
WARNING Prolonged exposure to elevated temperatures is capable of inducing hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of
98.6°F. The symptoms of hyperthermia include an increase in the normal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of the hyperthermia include failure to perceive heat, failure to recognize the need to exit the room, unawareness of impending hazard, fetal damage in pregnant women, physical inability to exit the room and unconsciousness.

Page 1

WARNING
Do not take a sauna if using
alcohol, drugs or
medications.
Pregnant women or persons
with poor health should
consult their physician before
using any sauna.
Caution re hazard: Do not
use the sauna room for
drying clothes, bathing suits,
etc. Do not hang towels
above heater or place any
object other than the rocks
supplied on the heater. If any
darkening of the wall around
the heater is noticed
discontinue sauna use
immediately.
Inspect sauna regularly for
required maintenance to
heater, control and benches.
Replace wood surfaces
which show any signs of
deterioration.
The heater gets extremely hot
during operation and should
not be touched or burns may
result.
WARNING The use of alcohol, drugs, or medication is capable of greatly increasing the risk of fatal hyperthermia.
SECTION 1: GENERAL INFORMATION
These heaters are ETL approved for permanent installations and electrical connections. Built with splash proof construction, the conducting parts are protected against water. All wiring must be performed in accordance with national and local codes. See Diagram 2 for wire and room size requirements. These heaters are wall mounted.
72-0119 12-26-2019 C 7013617 314 SKPS 14
Minors should be adequately
supervised whenever near a
hot or warming sauna.
INSTALLATION AND OPERATING INSTRUCTIONS
Floor Area
Wall
Height
Volume
Cu.Ft.
Wall
Height
Volume
Cu.Ft.
Power Supply to
CB Box
CB Box to Heater
Junior 1.7
1517-17-02
1.7 7 sq. ft. 73 1/2" 60 84" 80 1 120 14.2 2 #12AWG+GR 2 #12AWG+GR
1 120 18.3 2 #12AWG+GR 2 #12AWG+GR 1 240 9.2 2 #12AWG+GR 2 #12AWG+GR
8 sq. ft.
73 1/2"7084"
PHASE
VAC
AMPS
WIRE SIZE
100
Junior 3.0
1517-30-02
3.0
12 sq. ft.
73 1/2"
100
84"
150
Junior 2.2
1517-22-02
2.2
HEATER MODEL
/ Product
Number
1
240
12.5
2 #12AWG+GR
2 #12AWG+GR
KW
MINIMUM ROOM
MAXIMUM ROOM
DIAGRAM 1
MOUNTING BRACKET LOCATION AND MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL

Page 2

Temperature
3"
Sensor
2”
2”
6"
1"
2"
14"
3/4
9 "
1”
Use the long screws in the upper holes of the mounting bracket
Recheck your distances from the heater to combustible materials to be sure you have the proper minimum distances.
Screws
3"
Temperature
Sensor
1/2
47 "
5”
1"
8"
1/4
20 "
2"
18"
CB Box
4"
OBSERVING MINIMUM DISTANCES IS REQUIRED TO REDUCE FIRE HAZARD
1/2
73 "
NOTE: All installation and service to this equipment should be performed by qualied licensed personnel in
accordance with local and national codes.
NOTE: A GFCI (Ground Fault Interrupt Circuit) device is not required by NEC. A GFCI may be installed if required by local codes but will nuisance trip during use of the product.
CAUTION: Loose wire connections can cause heat damage to wires, terminal blocks and other components and may void the warranty.
72-0119 12-26-2019 C 7013617 314 SKPS 14
DIAGRAM 2
INSTALLATION AND OPERATING INSTRUCTIONS
DIAGRAM 3
3"
Sensor Location
Locate sensor 3" from ceiling directly
above the sauna heater.

Page 3

48"
84"
SaunaLogic 2
Control
(Model 1601-38)
SL2 Control
2x4 Supports
DIAGRAM 4
Tongue and Groove
Upper Bench
Lower Bench
Minimum spacing
CB BOX
18"
CB Box can be outside of the sauna room or installed inside sauna room.
DIAGRAM 5
Back of sensor
3/4
17 "
1/4
18 "
Insert screwdriver tip here to unsnap sensor cover from sensor. Note vertical orientation of cover before removing.
72-0119 12-26-2019 C 7013617 314 SKPS 14
INSTALLATION AND OPERATING INSTRUCTIONS
DIAGRAM 6
WIRING DIAGRAM: CONTROL AND HEATER MODELS
Junior 1.7, & 2.2 (ETL#'s 1517-17-02, 1517-22-02) SL2 (1601-38) and CB 13-1
Junior Heater
SL2 Control
(1601-38)
Sensor
1517-17-02 or 1517-22-02
Back Element
Front Element

Page 4

Lights
(Optional)
CN4
CN 1
(RJ 11)
CN8 Light (RJ 45)
CN 7 Bluetooth Power
1 2
CN5
Jumper Closed
12
VDC
Power Supply
CN 6
CN 2
120
VAC
XT-1613-Z
F12AF2
2A
CN 3
T1
Rly 5
T1
T2
T2
Rly 8
GND
GND
Rly 6
Rly 9
Rly 2
Rly 3
CB 13-1
120V / 1Ph Connection
354 SKPS 7 D
72-0119 12-26-2019 C 7013617 314 SKPS 14
12/27/2019
Power Input
GNDL1 N
24-0001 Rev D
INSTALLATION AND OPERATING INSTRUCTIONS

Page 5

DIAGRAM 6 (Cont.)
WIRING DIAGRAM: CONTROL AND HEATER MODELS
Junior 2.2 & 3.0 (ETL#'s 1517-22-02, 1517-30-02) SaunaLogic 2 (1601-38) and CB 16-1
Junior Heater
SL2 Control
(1601-38)
Sensor
1517-22-02 or 1517-30-02
Back Element
Front Element
Lights
(Optional)
CN4
CN 1
(RJ 11)
CN8 Light (RJ 45)
CN 7 Bluetooth Power
1 2
CN5
Jumper Closed
12
VDC
Power Supply
CN 6
CN 2
240
VAC
XT-1613-Z
F12AF2
2A
CN 3
T1
Rly 5
T1
T2
Rly 8
T2
GND
GND
Rly 6
Rly 9
Rly 2
Rly 3
CB 16-1
240V / 1Ph Connection
12/26/2019
72-0119 12-26-2019 C 7013617 314 SKPS 14
GNDL1 L2
Power Input
354 SKPS 8 C
24-0007 Rev C
Loading...