Tyler Refrigeration NSSD User Manual

Installation && SService
Manual
NSSD
This manual has been designed to be used in conjunction with the General
(UL/NSF) Installation & Service Manual.
Save the Instructions in Both Manuals for Future Reference!!
This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 1999.
PRINTED IN Specifications subject to REPLACES ISSUE PART IN U.S.A. change without notice. EDITION
3/02 DATE 10/02 NO. 9037171 REV. A
Tyler Refrigeration Corporation * Niles, Michigan 49120
THREE DECK MEAT/DELI/CRITICAL TEMP
PRODUCE MERCHANDISERS WITH CURVED FRONT GLASS
Medium Temperature Self Serve Display Cases
S P E C I A L T Y
P R O D U C T S
CONTENTS
NSSD Tyler Refrigeration
Page 2 March, 2002
Page
Specifications
NSSD Specification Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Line Sizing Requirements . . . . . . (See General-UL/NSF I&S Manual)
Pre-Installation Responsibilities . . . . . (See General-UL/NSF I&S Manual)
Installation Procedures
Carpentry Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Case Pull-Up Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Plumbing Procedures . . . . . . . . (See General-UL/NSF I&S Manual)
Refrigeration Procedures . . . . . (See General-UL/NSF I&S Manual)
Electrical Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Defrost Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Defrost Control Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation Procedure Check Lists (See Gen.-UL/NSF I&S Manual)
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
NSSD Domestic & Export (50Hz) Case Circuits . . . . . . . . . . . . . 8
Cleaning and Sanitation
Component Removal and Installation Instructions for Cleaning 12
Shelves and Shelf Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Bottom Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Front Air Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Rear Duct Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Discharge Air Honeycomb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Front Lower Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Front Upper Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installation & Service Manual NSSD
Page 3March, 2002
Page
General Information
NSF Product Thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Radiant Heat Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Radiant Heat Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Display Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service Instructions
Preventive Maintenance . . . . . . (See General-UL/NSF I&S Manual)
Light Servicing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ballast and Lighting Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ballast Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Defrost Heater Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Fan Blade and Motor Replacement (See Gen.-UL/NSF I&S Manual) Color Band and Bumper Replacement (See Gen.-UL/NSF I&S Man.)
Anti-Sweat Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Top Light Channel Anti-Sweat Replacement . . . . . . . . . . . . . . . . . 16
Front Curved Plexiglas Replacement . . . . . . . . . . . . . . . . . . . . 16
Parts Information
Operational Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Cladding and Trim Parts Lists . . . . . . . . . . . . . . . . . . . . . . . . . . 18
TYLER Warranty . . . . . . . . . . . . . . . . . (See General-UL/NSF I&S Manual)
The following Medium Temperature, Top Display Meat, Deli and Critical Temp Produce Merchandiser models are covered in this manual:
MODEL DESCRIPTION NSSD 6’, 8’ & 12’ CURVED GLASS FRONT 3-DECK MEAT/DELI
MERCHANDISER
NSSD Tyler Refrigeration
Page 4 October, 2002
SPECIFICATIONS
NSSD Three Deck Meat/Deli/Critical Temp Produce Merchandisers
Installation & Service Manual NSSD
Page 5
October, 2002
NSSD Three Deck Meat/Deli/Critical Temp Produce Merchandisers
NSSD Tyler Refrigeration
Page 6 March, 2002
INSTALLATION PROCEDURES
Carpentry Procedures
Case Line-Up
NOTE
The NSSD cases are shipped on casters that are replaced with adjustable legs during case line-up and installation.
See the “General-UL/NSF I&S Manual” for the proper case line-up procedures.
Case Pull-Up Locations
All NSSD models have four pull-ups at each end of the case. Pull-ups A, B, C and D are located as shown and should be installed and tightend starting with A and finishing with D.
See “General-UL/NSF I&S Manual” for line­up assembly instructions.
Electrical Procedures
Electrical Considerations
CA
UTION
Make sure all electrical connections at com­ponents and terminal blocks are tight. This prevents burning of electrical terminals and/or premature component failure.
NOTE
The NSSD has two raceway locations that can house the electrical wiring, components and terminal blocks. All components and wiring can be located in either the lower front or the lower rear of the case.
Case Fan Circuit
This circuit is to be supplied by an uninterrupt­ed, protected 120V circuit. The case fan circuit is not cycled, except when equipped for gas defrost. On gas defrost cases the fan circuit is controlled by a 50/40 klixon.
NOTE
With gas defrost, the fans will not start until the coil temperature reaches 40°F at the fan delay thermostat.
Fluorescent Lamp Circuit
Case lighting is supplied by T-8 electronic ballast lights. It is controlled by a light switch in each case. The standard lighting is 1-row of T-8 canopy lights. NSSD models also offer up to 3 rows of optional T-8 shelf lights.
Anti-Sweat Heater Circuit
NSSD cases have three anti-sweat heaters. One in the top light assembly, one in the front glass trim rail and one in the front glass retain­er. All anti-sweat heaters are wired directly to the main power supply so they can operate at all times.
Loading...