Tyler Refrigeration N5D, N5DH, N5DSC, N5DL User Manual 2

Installation & Service
Manual
N5D, N5DH, N5DL, N5DSC
This manual has been designed to be used in conjunction with the General
(UL/NSF) Installation & Service Manual.
Save the Instructions in Both Manuals for Future Reference!!
This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 1999.
1/01 NO. 9037155 REV.
Tyler Refrigeration Corporation * Niles, Michigan 49120
NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS
Medium Temperature Refrigerated Display Cases
CONTENTS
N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 2 January, 2001
Page
Specifications
N5D/N5DH/N5DL/N5DSC Specification Sheets . . . . . . . . . . . . . . . 4
Pre-Installation Responsibilities . . . . . (See General-UL/NSF I&S Manual)
Installation Procedures
Carpentry Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Case Pull-Up Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Plumbing Procedures . . . . . . . . (See General-UL/NSF I&S Manual)
Refrigeration Procedures . . . . . (See General-UL/NSF I&S Manual)
Defrost Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Defrost Control Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Procedure Check Lists (See Gen.-UL/NSF I&S Manual)
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
N5D/N5DH/N5DL Domestic & Export (50Hz) 4’ Case Circuits . . . . 7
N5D/N5DH/N5DL Domestic & Export (50Hz) 6’ Case Circuits . . . . 8
N5D/N5DH/N5DL Domestic & Export (50Hz) 8’ Case Circuits . . . . 9
N5DSC Domestic & Export (50Hz) 4’ and 6’ Case Circuits . . . . . . 10
Canopy Lighting Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Optional Shelf Light Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cleaning and Sanitation . . . . . . . . . . . (See General-UL/NSF I&S Manual)
Component Removal and Installation Instructions for Cleaning 13
Mirrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Shelves and Shelf Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Bottom Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Front Air Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Rear Duct Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Discharge Air Honeycomb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Top Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Lower Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Upper Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installation & Service Manual N5D, N5DH, N5DL, N5DSC
January, 2001 Page 3
P
age
General Information
NSF Product Thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Service Instructions
Preventive Maintenance . . . . . . (See General-UL/NSF I&S Manual)
Troubleshooting Self-Contained Units . . . . . . . . . . . . . . . . . . . . 15
Light Servicing
Ballast and Lighting Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fan Blade and Motor Replacement (See Gen.-UL/NSF I&S Manual) Color Band and Bumper Replacement (See Gen.-UL/NSF I&S Man.)
Parts Information
Operational Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Cladding and Optional Trim Parts List . . . . . . . . . . . . . . . . . . . . 18
TYLER Warranty . . . . . . . . . . . . . . . . . (See General-UL/NSF I&S Manual)
The following Narrow Medium Temperature Dairy and Deli Merchandiser models are covered in this manual:
MODELS DESCRIPTION N5D 4’, 6’ & 8’ REMOTE MULTI-DECK DAIRY/DELI MERCHANDISER N5DH 4’, 6’ & 8’ REMOTE DEEP WELL MULTI-DECK
DAIRY/DELI MERCHANDISER
N5DL 4’, 6’ & 8’ REMOTE LOW FRONT MULTI-DECK
DAIRY/DELI MERCHANDISER
N5DSC 4’ & 6’ SELF-CONTAINED MULTI-DECK DAIRY/DELI MERCHANDISER
N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 4 January, 2001
SPECIFICATIONS
N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser
Installation & Service Manual N5D, N5DH, N5DL, N5DSC
Page 5January, 2001
N5D/N5DH/N5DL/N5DSC Multi-Deck Dairy/Deli Merchandiser
N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 6 January, 2001
INSTALLATION PROCEDURES
Carpentry Procedures
Case Pull-Up Locations
The N5D, N5DH, N5DL and N5DSC models have four pull-ups at each end of the case. Pull-ups A, B, C and D are located as shown and should be install-ed and tightened starting with A and finishing with D.
See “General-UL/NSF I&S Manual” for line­up assembly instructions.
Electrical Procedures
Electrical Considerations
CA
UTION
Make sure all electrical connections at com­ponents and terminal blocks are tight.
NOTE
Since the lower front cladding is shipped loose, the wiring has immediate access.
Case Fan Circuit
This circuit is to be supplied by an uninter­rupted, protected 120V circuit. The case fan circuit is not cycled during defrost on any of these models.
Fluorescent Lamp Circuit
N5D/N5DH/N5DL/N5DSC case lighting is supplied by 800MA HO horizontal lights. It is controlled by a light switch in each case. The standard lighting is 1-row of high output 800MA canopy lights. N5D/N5DH/N5DL/N5DSC also offers up to 4 rows of T-8 shelf lights with remote electronic ballasts.
Self-Contained Circuit
LNDSC cases are self-contained units. Information pertaining to self-contained units should be obtained directly from TYLER Refrigeration.
Defrost Information
See “General-UL/NSF I&S Manual” for operational descriptions for Off Time defrost control.
Defrost Control Chart
Defrost Defrost Defrosts Duration Term. T
ype Per Day (Min) Temp.
Off Time 4 24 -----
WIRING DIAGRAMS
ELECTRICIAN NOTE - OVERCURRENT
PROTECTION
120V circuits should be protected by 15 or 20 Amp devices per the requirements noted on the cabinet nameplate or the National Electrical Code, Canadian Electrical Code - Part 1, Section 28. 208V defrost circuits employ No. 12 AWG field wire leads for field connections. On remote cases intended for end to end line-ups, bonding for ground may rely upon the pull-up bolts.
The following wiring diagrams on pages 7 thru 12 will cover the N5D, N5DH, N5DL and N5DSC case circuits and the lighting circuits.