Tyco Safety Software House RMXIC Users Manual

RM-iC Series
Quick Start
Installation Guide
Version B.0
Part Number UM-068
December 2004
PRODUCT

Specifications

Standards

The RM-iC series readers provide an enclosed RM-4 board and attached iCLASS read head, available in the following styles:
RM1-IC - enclosed RM-4 and attached iCLASS read head
RM2-IC - enclosed RM-4 with keypad and attached iCLASS read head
RM2L-IC - enclosed RM-4 with keypad, LCD display, and attached iCLASS read
head
The RM-iC Quick Start Installation Guide provides a synopsis of installation and connection information for RM-IC series readers. Refer to the RM-4/RM-4E Technical Manual for in-depth technical and installation information.
The following specifications apply to all RM-iC series readers:
Power: 12VDC, 300 mA
Cable: Beldon 9841
Cable distance from iSTAR or apC: 4,000 ft
Temperature: 32° F to 140° F (0°C to 60°C)
Qualified on 26 bit, 35 bit, 37 bit and 32 bit Mifare serial number card formats
RM1-IC series readers are Underwriters Laboratories Inc.(UL), Listed to Standard UL 294, Access Control System Units, Fifth Edition.
RM-iC series readers must be installed within a protected premise in accordance with the National Electrical Code (ANSI/NFPA 70), local codes, and the authorities having jurisdiction.
1

Installation

INSTALLATION
Installing the Mount
Plate
Installing an RM-iC series reader involves:
1. Installing the mount plate
2. Wiring the components
3. Grounding and shielding the wire bus
4. Setting the RM-4 address
5. Installing the ARM-1 relay board
6. Installing the heater kit.
Figure 1 shows RM-iC standard housing and mount plates. All RM-iC series readers conform to the same housing and mount plate dimensions.
Standard Housing
Housing screws
FIGURE 1. Standard Housing and Mount Plate
Figure 2 shows mount plate dimensions.
Standard mount plate
2
5.45"
Installation

Wiring the Components

+12V
TXD/RXD+ TXD/RXD-
GND
+12V Relay Power Relay 1 Drive Relay 2 Drive
(Pin 4 &5) Input 1
(Pin 6 & 7) Input 2
Wiring access
1.54"
1.82"
Figure 3 shows RM-4 wiring.
P1- Reader port wiring
1
P1
4
1
P5
7
P5 Door Inputs
and Outputs
J5- Chassis ground wiring
2.47"
1.29"
.83"
8x
2.73"
3.64"
3.92"
Mounting hole
0.156" Thru, 0.280” Countersink
FIGURE 2. Mount Plate Dimensions
J2
8
1
J5
SW3
6
1
Position 1 Magnetic Off
Wiegand On
Position 2 LCD Off
Position 3 LED (normal) Off
Position 4 Tamper (normal) Off
Position 5 EOL terminate Off
Position 6 LED (normal) Off J4-3 wire-or red and green On
4.11"
3.66"
4.94"
SW1­Address switch
SW1
No LCD On
Ext. bi-color On
Tamper (bypass) On
Not terminated On
FIGURE 3. RM-4 Wiring Requirements
3