Tyco Safety Canada 005132 User Manual

• W A R N I N G •
This manual contains information on limitations regarding
product use and function and information on the limitations as to
liability of the manufacturer.
Installation
Manual
Please see page ii for a description of new
features for the PC5132-433 v3.12.
features for the PC5132-433 v3.12.features for the PC5132-433 v3.12.
PC5132-433
Version 3.12
WARNING Please Read Carefully
Note to Installers
This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible. There are circumstances, however, involving f ire, bur­glary, or other types of emergencies where it may not provide protection. Any alarm system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons. Some but not all of these reasons may be:
■■
Inadequate Installation
■■
A security system must be installed properly in order to provide adequate protection. Every installation should be evaluated by a security professional to ensure that all access points and areas are covered. Locks and latches on windows and doors must be secure and operate as intended. Windows, doors, walls, ceilings and other building materials must be of sufficient strength and construction to provide the level of protection expected. A re­evaluation must be done during and after any construction activ­ity. An evaluation by the fire and/or police department is highly recommended if this service is available.
■■
Criminal Knowledge
■■
This system contains security features which were known to be effective at the time of manufacture. It is possible for persons with criminal intent to develop techniques which reduce the ef­fectiveness of these features. It is important that a security sys­tem be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected.
■■
Access by Intruders
■■
Intruders may enter through an unprotected access point, cir­cumvent a sensing device, evade detection by moving through an area of insufficient coverage, disconnect a warning device, or interfere with or prevent the proper operation of the system.
■■
Power Failure
■■
Control units, intrusion detectors, smoke detectors and many other security devices require an adequate power supply for proper operation. If a device operates from batteries, it is possible for the batteries to fail. Even if the batteries have not failed, they must be charged, in good condition and installed correctly. If a device operates only by AC power, any interruption, however brief, will render that device inoperative while it does not have power. Power interruptions of any length are often accompanied by voltage fluctuations which may damage electronic equipment such as a security system. After a power interruption has oc­curred, immediately conduct a complete system test to ensure that the system operates as intended.
■■
Failure of Replaceable Batteries
■■
This system’s wireless transmitters have been designed to pro­vide several years of battery life under normal conditions. The expected battery life is a function of the device environment, usage and type. Ambient conditions such as high humidity, high or low temperatures, or large temperature fluctuations may re­duce the expected battery life. While each transmitting device has a low battery monitor which identifies when the batteries need to be replaced, this monitor may fail to operate as expected. Regular testing and maintenance will keep the system in good operating condition.
■■
Compromise of Radio Frequency
■■
(Wireless) Devices
Signals may not reach the receiver under all circumstances which could include metal objects placed on or near the radio path or deliberate jamming or other inadvertent radio signal interference.
■■
System Users
■■
A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary physical disability, in­ability to reach the device in time, or unfamiliarity with the cor­rect operation. It is important that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm.
■■
Smoke Detectors
■■
Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons, some of which
follow. The smoke detectors may have been improperly in­stalled or positioned. Smoke may not be able to reach the smoke detectors, such as when the fire is in a chimney, walls or roofs, or on the other side of closed doors. Smoke detectors may not detect smoke from fires on another level of the residence or building. Every fire is different in the amount of smoke produced and the rate of burning. Smoke detectors cannot sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches or arson. Even if the smoke detector operates as intended, there may be circumstances when there is insufficient warning to allow all occupants to escape in time to avoid injury or death.
■■
Motion Detectors
■■
Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceil­ings, floor, closed doors, glass partitions, glass doors or win­dows. Any type of tampering whether intentional or uninten­tional such as masking, painting, or spraying of any material on the lenses, mirrors, windows or any other part of the detec­tion system will impair its proper operation. Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.
■■
Warning Devices
■■
Warning devices such as sirens, bells, horns, or strobes may not warn people or waken someone sleeping if there is an intervening wall or door. If warning devices are located on a different level of the residence or premise, then it is less likely that the occupants will be alerted or awakened. Audible warn­ing devices may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or other appli­ances, or passing traffic. Audible warning devices, however loud, may not be heard by a hearing-impaired person.
■■
Telephone Lines
■■
If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods of time. Also an intruder may cut the telephone line or defeat its operation by more sophisti­cated means which may be difficult to detect.
■■
Insufficient Time
■■
There may be circumstances when the system will operate as intended, yet the occupants will not be protected from the emer­gency due to their inability to respond to the warnings in a timely manner. If the system is monitored, the response may not occur in time to protect the occupants or their belongings.
■■
Component Failure
■■
Although every effort has been made to make this system as reliable as possible, the system may fail to function as intended due to the failure of a component.
■■
Inadequate Testing
■■
Most problems that would prevent an alarm system from op­erating as intended can be found by regular testing and main­tenance. The complete system should be tested weekly and immediately after a break-in, an attempted break-in, a fire, a storm, an earthquake, an accident, or any kind of construction activity inside or outside the premises. The testing should in­clude all sensing devices, keypads, consoles, alarm indicating devices and any other operational devices that are part of the system.
■■
Security and Insurance
■■
Regardless of its capabilities, an alarm system is not a substi­tute for property or life insurance. An alarm system also is not a substitute for property owners, renters, or other occu­pants to act prudently to prevent or minimize the harmful ef­fects of an emergency situation.
Table of Contents
Introduction 1
1.1 How to use this Manual ....................................................................................... 1
1.2 Specifications and Features ............................................................................... 1
1.3 Compatible Wireless Devices ............................................................................. 2
1.4 Batteries .............................................................................................................. 2
PC5132 Set up & Wiring 3
2.1 Unpack the PC5132 ............................................................................................ 3
2.2 Choose a Mounting Location for the PC5132 .................................................... 3
2.3 Antennas ............................................................................................................. 3
2.4 Connect the PC5132 Receiver ........................................................................... 3
Enrolling Wireless Devices 4
3.1 A Note about Electronic Serial Numbers ............................................................ 4
3.2 Enrolling Wireless Devices (WLS904NB433, WLS907NB433) .......................... 4
3.3 Enroll & Program Wireless Keys (WLS909NB433) ............................................. 5
3.4 Identified Wireless Keys ..................................................................................... 6
Other Programming 7
4.1 Program Zones and Partitions ............................................................................ 7
4.2 Enable PC5132 Supervision ............................................................................... 7
4.3 Enable Supervision of Wireless Zones ............................................................... 8
4.4 Jamming Signal Detection .................................................................................. 8
4.5 PC5132 Software Default .................................................................................... 9
4.6 Deleting Wireless Devices .................................................................................. 9
Testing & Mounting 10
5.1 Test the Reception of Wireless Devices ........................................................... 10
5.2 Mount the PC5132 and Wireless Devices ........................................................ 11
Additional Notes 12
6.1 Trouble Conditions ............................................................................................ 12
6.2 Jamming Signal Detection ................................................................................ 12
6.3 Wireless Zone Low Battery Transmission ......................................................... 12
Troubleshooting 13 Programming W orksheets 14 Index 18
FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could
void your authority to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient the receiving antenna
Relocate the alarm control with respect to the receiver
Move the alarm control away from the receiver
Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for addi­tional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4.
hank you for purchasing the PC5132 Wireless Receiver. This product
is the result of several years of development and will allow you to connect
T
up to 8 wireless detection devices to the PC585, PC1565 and PC5008,
and up to 32 detection devices to the PC5015. The PC5132 uses 433 MHz. It provides several advantages:
• supervisory transmissions are sent every 12 minutes, as opposed to every
50-60 minutes
• programmable supervisory window can be as little as one hour, or as long
as 24 hours
• devices use standard alkaline batteries as opposed to specialized
batteries
• diversity antenna arrangement for better RF reception
In addition, the PC5132 features:
6 digit serial numbers for all wireless devices: These new serial
numbers include hexadecimal digits.
Electronic Serial Numbers (ESN)” for more information on enrolling 6-digit devices.
This product introduces these new features:
Wireless key support: Up to sixteen WLS909NB433 wireless keys can be
enrolled.
RF jamming detection: Two different RF jamming detection sensitivity
settings.
We are confident you will find the PC5132 Wireless Receiver a unique and useful control panel enhancement.
Please read Section 3.1 “A note on

Introduction

S E C T I O N 1
This manual describes how to install, program and maintain the PC5132. Before you install the PC5132 module, you should have completed the following
steps in your system installation:
1. Plan the installation and wiring of the security system (see your system
Installation Manual)
2. Install the control panel, and install and enroll at least one keypad to use
for programming.
3. Install and enroll any hardwired zone expander modules (PC5108) you
plan to use.
NOTE: PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9-12 and zones 13-16). None of the z ones assigned to a PC5108 module may be used for wireless devices.
Program the PC5132 from a system keypad or using downloading software on a remote computer (e.g. DLS-1). Read your system Installation Manual for more information.

1.1 How to use this Manual

Read this manual before you begin installing the PC5132. To install and set up the PC5132 and wireless devices, follow these steps. Refer to the sections listed below.
1. Temporarily mount and wire the PC5132 module (see
2. Enroll and program wireless devices (see
3. Complete zone and other programming on the system (see
4. Test the placement of all the wireless devices
5. Permanently mount the PC5132 receiver and wireless devices
Section 5)
For additional information on trouble conditions, RF jamming signal detection and battery replacement, see
For help with troubleshooting, see
Section 6.
Section 7.
Section 3
(see Section 5)
Section 2
)
)
Section 4
(see
)

1.2 Specifications and Features

• Current Draw: 80 mA
• Frequency: 433 MHz
• Zones - receiver can receive signals from up to 32 wireless zones
• Antenna - diversity design for enhanced performance
• Supervisory - programmable supervisory window, 1 to 24 hours, in 15
minute increments
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Keybus
- for longer wire runs, thicker gauge wire must be used.
• Compatibility: The PC5132 v3.12 can be connected to the following
panels: PC501X, PC5008, PC1565, PC585
1
I N T R O D U C T I O N

1.3 Compatible Wireless Devices

Please refer to the Instruction sheets of the following devices for more informa­tion.
The PC5132 v3.12 can receive signals from the following devices:
• WLS904NB433 Motion Detector
• WLS907NB433 Universal Transmitter
• WLS909NB433 Wireless Key

1.4 Batteries

The wireless devices are designed to use only Energizer Alkaline batteries (by Eveready).
NOTE: Do not use other brands of batteries. Using any other brand may affect system operation.
2

PC5132 Set up & Wiring

S E C T I O N 2
This section describes how to set up and wire the PC5132 module.

2.1 Unpack the PC5132

Check that the following parts are in your PC5132 package:
· PC5132 PCB
· PC5132 plastic cabinet

2.2 Choose a Mounting Location for the PC5132

NOTE: Mount the PC5132 receiver and wireless devices after you have done placement tests with the wireless devices (see sections 5.1 and 5.2).
Find a place that is:
• Dry
• Central to the proposed placement of all wireless devices
• As high as possible
• Far from sources of interference, including: electrical noise such as
computers, televisions and electric motors in appliances and heating and air conditioning units; large metal objects like heating ducts and plumbing which may shield the antenna.
Make sure that electrical wires will not run over the antenna(s) of the module when it is mounted.
When mounting the PC5132 in a basement, place the module as high and as close to the underside of the first floor as possible. The range of the module will be reduced if the unit is mounted below ground level.

2.3 Antennas

The antennas have been installed at the factory. They do not need any adjustment.

2.4 Connect the PC5132 Receiver

CAUTION: Remove all power from the system while connecting modules to the Keybus.
Connect the PC5132 to the four-wire Keybus of the control panel according to the following diagram.
After you have completed the wiring, reconnect the power to the security system.
Now that you have wired the PC5132, you should enroll and program the wireless devices. See section 3 for instructions.
3
Enrolling Wireless Devices
S E C T I O N 3
This section describes how to enroll wireless devices (WLS904NB433, WLS907NB433), and wireless keys (WLS909NB433). For more information on these devices, read the instruction sheet included with each device.

3.1 A Note about Electronic Serial Numbers

An electronic serial number (ESN) is printed on the back of each wireless device. ESNs are used to enroll the wireless devices with the PC5132 receiver.
In order to reduce the occurrence of wireless devices with the same serial number, 6-digit serial numbers are now printed on the back of each wireless device. The 6-digit serial numbers include hexadecimal digits. For instructions on programming hexadecimal numbers, see your system Installation Manual, section 4: How to Program.
NOTE: 6-digit serial numbers are only supported on the following control panels: PC501X, PC5008, PC1565 and PC585 v2.0 and higher.
The WLS904NB433 and WLS907NB433 devices have both a 5-digit and a 6­digit serial number printed on them. When connecting the PC5132 to a PC5015 v1.x panel, enter 5-digit serial numbers only. When connecting the PC5132 to a PC5015 v2.x and higher, PC5008, PC1565 or PC585 panel enter the 6-digit serial number.

3.2 Enrolling Wireless Devices (WLS904NB433, WLS907NB433)

1. At a system keypad, enter [][8][Installer’s code] to go to the installer’s
programming section.
2. Enter programming section [804].
3. Enter the 2-digit number corresponding to the zone the device is to
occupy ([01] to [32]).
NOTE: Hardwired and wireless devices cannot be assigned to the same zone. PC5108 zone expander modules occupy zones in 2 groups of 4 (e.g. zones 9­12 and zones 13-16). None of the zones assigned to a PC5108 module may be used for wireless devices. For more information on zone assignment, consult your system Installation Manual.
4. Enter the device’s ESN. Follow the instructions in section 3.1 above.
5. Record the serial number and the assigned zone number in the
programming worksheets in the back of this manual.
6. Continue with steps 3 - 5 until you have enrolled all wireless devices.
7. To exit press [#]. The device is now enrolled on the system.
NOTE: The devices will not work properly until you complete zone and partition programming (see section 4).
4
Loading...
+ 16 hidden pages