Tyco Safety Canada 00433904 User Manual

WLS904L
Wireless Motion Detector
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONSINSTALLATION INSTRUCTIONS
Each WLS904L motion detector should be located so that it provides optimal coverage of the intended area. Refer to Changing Motion Detector Lenses below for information on the four lenses available for the WLS904L Motion Detector. When locating motion detectors, observe the following:
• For the Wall-to-Wall, Corridor and Curtain Lenses, the Mounting Height should be 6-10 ft./ 2-3 m from the floor. The nominal mounting height is
7.5 ft./ 2.3 m.
• For the Pet Alley Lens only, the Mounting Height should be 4-5 ft./1.2-1.5m from the floor.
• Avoid locations that are subject to direct air flow, such as near an air duct outlet.
• Do not locate the detector near sources of steam or oil vapor, such as a stove or fryer.
• Do not obscure the Detector’s coverage pattern with large objects within the detection area. If you can’t see the detector, it can’t see you.
• For indoor use only
• Dead zone 6”/15 cm
NOTE: No detector should be mounted without first performing a module placement test to determine that it is in range of the wireless receiver. See the Placement Test instructions in the Instruction Sheet for your receiver, or in the installation manual for your system.
When a location has been determined, remove the plastic from the mounting holes and locate the backplate on the wall and mark screw locations. It is suggested that wall anchors be used for all screw locations. Secure the backplate to the wall, and then secure the enrolled Detector to its backplate.
Motion Detector Backplate
ENSURE PROPER ORIENTATION OF BACKPLATE.
MOUNTING HOLE KNOCKOUTS
CORNER MOUNTING KNOCKOUTS
• W A R N I N G •
Please refer to the System Installation Manual for information on
limitations regarding product use and function and information
on the limitations as to liability of the manufacturer.
Changing Motion Detector Lenses
Each motion detector is supplied with the Wall-to-Wall lens; three additional lenses are available for the WLS904L motion detector. The charts on this page illustrate the range and coverage patterns of each lens.
To change the lens, first open the motion detector by removing the screw in the bottom of the battery compartment. With the screw removed, pull the back of the detector away from the front case.
NOTE: The coils and antenna on the motion detector circuit board are very sensitive components precisely adjusted for maximum performance. Do not touch the coils or antenna! Even minor distortions can affect the performance of the motion detector.
Remove the lens holder by pressing down on the top of the holder and pulling the holder away from the case. When installing the new lens, ensure the grooved surface faces the interior of the case, and the notches on the lens face the bottom of the case. Replace the lens holder by snapping it back into place.
Reassemble the motion detector by first engaging the clips on the bottom of the case. Close the case and then secure the case with the screw in the bottom of the battery compartment.
Wall-to-Wall Lens Pet Alley
DSC Model BV-L1 DSC Model BV-L4
Range: 50' L × 60' W (16 m × 18 m) Range: 50' L × 60' W (16 m × 18 m)
TOP VIEW
30 ft
9.1 m
15 ft
4.6 m
0ft 0m
15 ft
4.6 m
30 ft
9.1 m
50 ft
SIDE VIEW
15.2 m
15.2 m
50 ft
TOP VIEW
SIDE VIEW
50 ft
15.2 m
50 ft
15.2 m
30 ft
9.1 m
15 ft
4.6 m
15 ft
4.6 m
30 ft
9.1 m
0ft 0m
Corridor Lens Curtain Lens
DSC Model BV-L2 DSC Model BV-L3
Range: 120' L × 10.5' W (36.5 m × 3 m) Range: 50' L × 4.4' W (16 m × 1.3 m)