Tycon Power UPS-ST24-100-8-UBNT User Manual

UPS-ST24 300W UBNT
UPSProBackup
Power System
Wireless Base Stations
Surveillance Cameras
Remote Gate Control
Up to 192W loads
Congratulations! on your purchase of the UPSPro outdoor backup power system. Please take a moment to review this Qwik Install Guide before assembly or battery installation.
DANGER! Avoid Powerlines!
You Can Be Killed!
When following the instructions in this guide take extreme care to avoid contact with overhead power lines, lights and power circuits. Contact with power lines, lights or power circuits may be fatal. We rec­ommend to install no closer than 20 feet to any power lines.
Safety: For your own protection, follow these safety rules.
Perform as many functions as possible on the ground Do not attempt to install on a rainy, windy or snowy day or if
there is ice or snow accumulation at the install site or if the site is wet.
Make sure there are no people, pets, etc. below when you are
working on a roof or ladder.
Recommended Tools: Phillips Scr ewdriver, 13mm and
10mm Open End Wrench, 8mm nut driver, Flat Blade Screwdriv-
Please help preserve the environment and return used batteries to an authorized depot
Qwik Install
STEP 1: Add Grounding Wire
Between Door and Enclosure: Remove plastic covers on cop­per studs on inside of door and inside of enclosure. Add jumper wire between 2 copper studs and use copper washers and nuts to secure.
STEP 2: Add wire feedthrus into
the bottom connector plate. Attach the connector plate to the bottom of the enclosure using self tapping screws provided.
STEP 3: Install hole plug in drain hole in bottom right corner of the en-
closure.
STEP 4: Mount the DIN rail to the door using screws provided. Mount
any extra equipment to the orange backplate and secure the backplate in the enclosure. Note: The DIN rail can also be mounted to the orange backplate if desired.
2
STEP 4: If p ole moun ting the en-
closure, assemble the pole mount kit
to the back of the enclosure and mount the enclosure to a pole using the 6 hose clamps provided. The en­closure can also be wall mounted using the 4 holes in the back of the enclosure.
STEP 5: Insert the battery platform in the bottom of the enclosure. The
battery platform has cutouts so wires can be routed under the battery as needed.
STEP 6: Attach the green DIN Rail adapt­ers to the 8 port POE switch using the screws provided. Clip the POE switch to the DIN rail. Connect a cable from the controller LOAD output to the 8 port POE switch green voltage in connector V+ and V-. There are two V+ and two V– inputs. Either input is fine to use.
Just make sure polarity is correct.
STEP 7: Install the b atter ies in the enclosure. If using multiple bat­teries, connect in series for 24V output.
24V two battery and 24V four battery configurations are shown below. Batteri es are c onn ected in s e-
ries, with Plus(+) connected to Minus(-).
3
STEP 8: If batteries ar e installed on their side make
sure to apply an insulator to the top of the battery termi-
nal to prevent the battery terminals from shorting to the metal enclosure in case the battery shifts inside the en­closure during an earthquake.
STEP 9: Set the proper voltage on the AC input of the controller by removing the metal tab and then switch­ing the input voltage to 120VAC or 240VAC depending on your source voltage. Be sure to replace the metal tab to ensure that somebody doesnt accidentally switch the voltage as this will damage the controller.
STEP 10: Connect the b attery cab les t o the con troller , then to the
battery. Be sure to observe proper polarity. Black wire connects to bat-
tery negative terminal and BATTERY(-) terminal on the controller.
STEP 11: When a battery is connected p rop erly the B ATT LED will be green. Make sure that the Battery Type is selected correctly and never change the battery type during charging or this could damage the controller. Use GEL for GEL or AGM batteries. Use WET for standard lead acid wet cells. Tycon recommends using only GEL or AGM batter­ies for best performance.
The controller has battery overdischarge protection to disconnect the load if the battery voltage (charge) is too low. The LOAD LED will be on when the battery charge is within safe limits and the LOAD output is turned on.
LED Indicators
LOAD (Load Pow er i s Turned On = Green) PWR (AC Pow er On = Yell ow ) BATT ( Batt ery is Connected = Green) CHD ( Battery is Full y Char ged = Green) CHG ( Battery is Charging = Yellow) WET / GEL – Switch is positioned to WET(Green) or GEL
(Yellow)
4
STEP 12: Switch off con troller and connect AC to the controller. Be sure to follow local regulations for outdoor 120/240VAC connec­tions.
STEP 13: Connect the load t o th e controller LOAD terminals. Be sure to observe proper polarity. Switch on the controller to activate the charging.
STEP 14: Plu g or Tighten all wire feed thrus. If they don t tighten on a small diameter wire, you can wrap some electrical tape around the wire in the seal area to increase its diameter and make a better seal.
The enclosure needs some small amount of venting so be sure NOT to
seal all holes and feedthrus with silicon.
STEP 15: Make sure lid gasket is clean and free from any parti­cles, then carefully close the cover, making sure that wires are clear of the seam and hinge area. Use the special key to close the two cover locks.
5
SPECIFICATIONS
Load Voltage (DC)
Max Load Output
Min Load Output
Available Storage Capacities
Battery Type
Battery Life
Charge Voltage
Over-discharge protection
Self Consumption
POE Switch Output
POE Switch
POE Protections
VAC Input +/- 10%
VAC Input Current
7 POE Ports 24VDC @ 2A per port max
UPS-ST24-UBNT
24V +/- 5%
12A
1A
2 battery 51Ah 1200VA
4 battery 102Ah 2400VA
Valve Regulated Sealed Lead Acid /
GEL
5 Years
WET Equalize = 28.8V, Float = 26.4V
GEL Equalize = 28.4V, Float = 27V
21.5V Load Off
25.2V Load On
<5.5W
1 Uplink Port
10/100Mb IEEE802.3/802.3u Auto
Crossover
Over Temp, Over Current, Short, Over/
under voltage, Surge
Selector Switch 120VAC / 240VAC ,
50/60Hz
3.5A @ 115VAC / 1.8A @ 240VAC
Subject to change without notice
Fuse
Enclosure Type
Operating Temperature
6A Internal Replaceable
Powder Coat Steel
-30°C to +60°C
TECH CORNER
Additional Information you may find useful
1. CONTROLLER: The controller turns off power to the load 21.5 and reconnects when the battery reaches 25.2V. This protects battery from overdischarge and increases battery life and performance. Note: The load will turn on immediately as soon as AC power is restored.
2. CAPACITY: Th e UPSProUPS-ST24 is rated at 192W load out- put. It can deliver 288W to the load but then the power available for bat­tery charging is too small, so we recommend not to exceed 192W to the load for best performance.
6
3. VENTING: The enclosure is vented thru the wire feedthrus and vari-
ous hole plugs in the bottom of the enclosure. Dont make these airtight
with silicon
4. BATTERY MAINTENANCE: The batteries used in the UPSPro sys- tems dont require any maintenance. They should last up to 5 years in normal use. Note: Never store batteries for any length of time in a dis-
charged state or it will kill the battery.
5. BATTERY OVERDISCHARGE: We highly reco mmend hooking
all equipment loads to the controller voltage output. This output will dis­connect the load if the battery voltage drops below the set voltage and this will protect the battery from over-discharge. If batteries get com­pletely discharged because the equipment was connected directly to
the battery, you will reduce the battery life. Discharged batteries will
freeze at very low temperatures.
6. ACCESSORIES: Tycon al so offers a variety of voltage conver­sion products to meet almost any need. Just visit tyconpower.com for more info.
Limited Warranty
The UPSProproducts are supplied with a limited 24 month warranty which covers material and workmanship defects. This warranty does not cover the following:
Parts requiring replacement due to improper installation, misuse,
poor site conditions, faulty power, etc.
Lightning or weather damage. Physical damage to the external & internal parts. Products that have been opened, altered, or defaced. Water damage for units that were not mounted according to user
manual. Usage other than in accordance with instructions and the normal intended use.