Tycon Power TP-SSW5-NC User Manual

5 port PoE Endspan (Switch)
USER’S MANUAL
TYCON POWER SYSTEM
User’s Manual
3
3
8
TYCON TP-SSW5(-NC)
1. General Information..............................................................
2. Hardware Description...........................................................
LED Indicators.......................................................................................
Power Wiring ........................................................................................
Ethernet Port Wiring..............................................................................
PD Port Wiring......................................................................................
3. Technical Specification........................................................
3 5
6 7
TYCON POWER SYSTEMS
2
User’s Manual
TYCON TP-SSW5(-NC)
1. General Information
The PoE (Power Over Ethernet) Switch support four ports 10/100 TX ports with PoE injector plus one 10/100TX up-link port. The switch provide Power over Ethernet functions to deliver 35Watts power budget to powered device(PD), which is in compliance with IEEE802.3af/at standard to deliver both of Ethernet data and DC power through the traditional UTP or STP cable to the PD. This manual will help you install and maintain the PoE switch. Installation of the PoE switch is very easy and you will begin to operate as soon as you are powered up.
2. Hardware Description *LED Indicator
There are 11 LEDs on the PoE switch to indicate the power and operational status. The following section describes the functions of each LED indicator.
Front panel detail
PoE Link/Act
TYCON POWER SYSTEMS
3
User’s Manual
*PWR Indicator
TYCON TP-SSW5(-NC)
LED Power
STATUS
Green
Description LED ON if power input has valid power apply.
Red
LED ON if the following condition happens. *Power input under voltage (Vin<10V) *Power input over voltage (Vin>59V) *PoE over current (2A/per port) the indicator is used on current model only.
Off No power in DC input
*SWITCH LED (the right indicator on RJ45)
LED STATUS Description P1~P4 & UP LINK Link/Act
Green
Blinking @43ms
Blinking @120ms
A network device is detected, but no communication activity is detected.
This port is transmitting to, or receiving package from another device at 100Mbps.
This port is transmitting to, or receiving package from another device at 10Mbps.
Off No device is detected.
TYCON POWER SYSTEMS
4
User’s Manual
*PoE LED(the left indicator on RJ45)
LED STATUS Description
TYCON TP-SSW5(-NC)
P1~P4 PoE
Yellow
Off
LED ON if with PoE output.
No PoE output.
*Power wiring
The PoE switch family includes 2 models, be used for different ranges of input voltage as,
Current model (2A maximum) ……….full range voltage (10 to 57VDC) (TP-SSW5-NC)
802.3af/at model…………………………48VDC typical (44 to 57VDC) (TP-SSW5)
For 802.3af/at model operation, make sure your power supply may offer at least 75W for 4x 802.3af PoE port, or 150W for 4x 802.3at PoE port. For current model operation, please make sure the output current don’t over 2A per port.
.For 802.3af/at operation, the input voltage must be in the range of 44 to 57 VDC. Otherwise, the PoEswitch will function only as an Ethernet switch but will not provide any PoE power output.
The PoE ports will deliver output of DC over the spare pairs of the RJ45 connection: * TX on lines 1 and 2 * RX on lines 3 and 6 * V+ on line 4 and 5 * V- on line 7 and 8
TYCON POWER SYSTEMS
5
User’s Manual
Rear panel terminal block wiring detail:
TYCON TP-SSW5(-NC)
You could use the TP-SSW5(-NC) with our adaptor products as the below: (OPTION)
PSHP-18 PSHP-24 PSHP-48
Maximum output 18VDC/7.5A 24VDC/6.25A 48VDC/3.125A
Max. Output Power of
the TP-SSW5-(NC)
135W 134.5W 134.5W
*Ethernet Port Wiring
The PoE Switch supports Port 1 to Port 5 with automatic MDI/MDI-X crossover, autosense of the speed and duplex for 10Base-T or 100Base-TX connections. Automatic MDI/MDI-X crossover allows you to connect to other devices (switches, hubs, or workstations etc..), without regard to using straight-through or crossover cabling.
Port 1 to port 4 also provides Power over Ethernet function which delivers DC power through the spare pairs (pair 4,5 and pair7,8) to the PD.
The following tables depict the wiring diagram of straight-through and crossover cabling. The crossover cables simply cross-connect the transmit lines at each end to the receive lines at the opposite end.
TYCON POWER SYSTEMS
6
User’s Manual
Straight-through Cabling
TYCON TP-SSW5(-NC)
Pin 1
Pin2
Pin3
Pin6
Cross-over Cabling
Pin 1
Pin 1
Pin 2
Pin 3
Pin6
Pin 3
Pin 2
Pin 3
Pin 6
Connect an Ethernet cable into any switch port and connect the other side to your attached device. The green Link/Act LED will light up when the cable is correctly connected. Refer to the LED Indicator section for descriptions of each LED indicator. If a port LED is off, go back and check for connectivity problems between that port and the network device it is connected to.
The maximum cable length for 10/100BaseT with Cat5 twisted pair cables is typically 100 meters
(328 ft.).
Pin 6
Pin 1
Pin 2
TYCON POWER SYSTEMS
7
User’s Manual
TYCON TP-SSW5(-NC)
*PD Port Wiring
Port 1 to 4 provide PoE inject function with maximum 35W(or 2A max.) ability to power up the powered device use the straight-through or cross-over Ethernet cable. The PoE switch follows the IEEE802.3af Alternative B mode connector assignment. The following table shows pin assignment of alternative A and B for the Power Source Equipment.
Conductor
Alternative A
(MDI-X)
1 Negative Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativenVport 7 Negative Vport 8 Negative Vport
Be sure the twisted pair cable is bound with the standard RJ-45 pin, especially the pin 4, 5, 7 and 8. If the RJ-45 is bound with the wrong pin number, PoE switch will not recognize the PD and won’t deliver DC power to PD. The yellow PoE LED will light up when the cable is correctly connected. Refer to the LED Indicator section for descriptions of each LED indicator. If a port LED is off, go back and check for connectivity problems between that port and the network device connected.
Alternative A
(MDI)
Alternative B
(All)
3. Technical Specifications
Standards IEEE802.3/IEEE802.3u standards(10 base-T/100base-T)
Ports 5 ports with 4 PoE(PSE), supports auto-crossover &
auto-polarity
Transmission speed 100 Mbps(100base-T),10 Mbps(10base-T) Auto-negotiation
Switch technology store-and-forward
Protocols CSMA/CD
TYCON POWER SYSTEMS
8
User’s Manual
TYCON TP-SSW5(-NC)
Flow control IEEE802.3x(full-duplex),back pressure(half-duplex)
Data transmission rate 148800pps for 100base-T, 14880pps for 10base-T
Address table 1K MAC address table, self-learning
Connect RJ-45
PoE port Port 1-4, auto power management Pin assignment: TX(1,2), RX(3,6), V+(4,5), V-(7,8)
Maximum PoE power IEEE802.3af – 16.8W IEEE802.3at – 35W Current limited – 2A
PoE disconnect mode DC disconnect
PoE auto detection IEEE802.3af & IEEE802.3at (2 event classification signaling)
PoE protection Over-temperature, over-current, over/under voltage
LEDs *Link/Activity (Green ON/ Green Blinking every 43ms @100Mbps/
Green Blinking every 120ms @10Mbps) *PoE(Yellow) On-PoE output *POWER Green-normal, Red-alarm
Power input DC(10V~57V).
Power consumption less than 5W when without PD loading
TYCON POWER SYSTEMS
Input Voltage Input Current
12V 0.032A 24V 0.022A 48V 0.019A 56V 0.019A
9
User’s Manual
Operating temperature
-40~ 85
Operation humidity 90% relative humidity, non-condensing
TYCON TP-SSW5(-NC)
Storage temperature
-55~+105
Dimension 40mm(H)x116mm(W)x90mm(D) (main body)
TYCON POWER SYSTEMS
10
Loading...