Tycon Power TP-SCPOE-12XX User Manual

Solar & PoE Battery Charger
USER’S MANUAL
TYCON
TYCON POWER SYSTEMS
User’s Manual
Features:
Battery Polarity Reverse Protection Battery Over Charge Protection Battery Over Discharge Protection Solar Panel Polarity Reverse Protection Solar Panel Over Charge Protection Output Short Circuit Protection Output Over Voltage Protection POE Output Short Circuit Protection POE Output Support 802.3af Function (TP-SCPOE-1248D)
TP-SCPOE-12XX Series
Two Input method:
(1)Solar Panel (2)PoE Power source (Always Solar First.)
Up to Three Outputs DIN Rail Mountable
User’s Manual
Panel Description:
Item Name Descriptions
TP-SCPOE-12XX Series
1 POE :
2
3
4 LOA :
5
6
7
SOL :
CHA :
REV :
IN :
OUT :
PoE power input indicator: the LED lights when the PoE input jack (the lower jack) has 18V~57V input.
Solar power input indicator: the LED lights when SOL terminal is connecting to a solar panel and the solar panel input voltage is over 12V.
Charging indicator: the LED lights when BAT terminal is connected to battery and charging
Loading indicator: the LED lights when the rear panel output terminal is connecting to a device and offering power. The LED always on when power ready.
Battery polarity reverse indicator: the LED lights when the battery polarities are reversed. (detail description see Sec. 5.1
PoE Input Jack: the lower RJ45 jack, used for PoE input. Allowed input voltage 18~57V
PoE Output Jack: the upper RJ45 jack, used for PoE output; Output voltage depends on what model you selected.
8 Fuse
9
10 BAT :
11
SOL :
LOA :
Fuse: for output over current protection, limiting the battery output current <= 10A. (If solar panel or PoE source is installed before the battery, and if the polarities of battery are reversed, then the fuse will be burnt.)
Solar Panel Terminal: used to connect the solar panel. Battery terminal: used to connect the battery.
NOTE: ALWAYS CONNECT THIS TERMINAL FIRST AND DISCONNECT LAST.
Load Terminal: The output voltage is the same as battery voltage. Maximum voltage clamped at 12.5V.
User’s Manual
TP-SCPOE-12XX Series
Operation Guide
NOTICE:
1. Connect the battery to the BAT terminal. Make sure the polarities are correctly connected. Sequentially connect the solar panel to SOL terminal and connect POE source to PoE input (lower) jack. (If solar panel or PoE source is installed before the battery, and if the polarities of the battery be
reversed, then the fuse will be burnt.)
2. Make sure the battery is properly connected to the unit. If no battery is connected, then the voltage at BAT terminal will be approx 13.8V
3. The solar panel cannot be used stand alone without battery connected.
4. When a solar panel and PoE input are connected to the charger, if the voltage of solar panel is higher than 15V, then solar panel is always the main power source of the charger.
5. When charge from solar panel, as the battery full and turn to floating stage, the CHA light will start flash, when charge from PoE, as the battery full, the CHA light will be turn off.
6.
When battery connect to BAT terminal and with valid voltage, then the LOA indicator will always light on even no load connected.
User’s Manual
TP-SCPOE-12XX Series

Electrical specifications
1.0 INPUT
1.1 Input Source types:
A. Solar Panel B. POE
1.2 Input Voltage: A. Solar Panel: 18V~36Vmax B. POE: 18V~57V
2.0 OUTPUT
Model TP-SCPOE-1212 TP-SCPOE-1218 TP-SCPOE-1224 TP-SCPOE-1248 TP-SCPOE-1248D
Output 1*
(at rear terminal)
Output 2
(at upper RJ45)
*maximum voltage clamped at 12.5V
3.0 Battery Charge Types:
4.0 Battery Types: 12V Lead Acid Battery
5.0 Protection:
5.1 Battery Polarity Reverse Protection:
5.2 Battery Over Discharge Protection:
12V/1.5A
(as Bat. Volt.)*
12V/1.0A
(as Bat. Volt.)*
12V/1.5A
(as Bat. Volt.)*
18V/1.67A
(regulated)
12V/1.5A
(as Bat. Volt.)*
24V/1.25A
(regulated)
12V/1.5A
(as Bat. Volt.)*
48V/0.625A
(regulated)
12V/1.5A
(as Bat. Volt.)*
48V/0.35A
(regulated)
A. Solar Panel: charge current depends on the wattage of the solar panel. B. POE: fixed current, 2.6A max
If only battery connected to terminal, when the battery polarities were reversed, the model will stop output and REV indicator light on.
When the battery be removed and re-connected to terminal, the function will be disable, if there is PoE power sources connected, when the battery polarities reversed, the fuse will be burnt.
Cuts off the load when the battery voltage is lower than 11V + 0.3V, and auto recover when the battery voltage returns to 12 V +
0.3V
User’s Manual
5.3 Battery Over Charge Protection:
5.4 Solar Panel Polarity Reverse Protection:
5.5 Solar Panel Over Charge Protection:
5.6 Output Short Circuit Protection:
5.7 Battery Output Current Limit:
5.8 Load Output Voltage Limit:
6. GENERAL DESCRIPTION
6.1 Operation Temperature: -20 - +60 Degree
6.2 Storage Temperature: -40 - +85 Degree
6.3 Operation Humidity: 5% - 90%
6.4 Cooling: Free air cooling
6.5 SIZE 150*118*40mm (L*W*H)
7. RJ45 Connected and pin out:
Fuse control, over 10A, the fuse will be burnt.
When solar panel polarities be reversed, the charger stop output, it won’t damage the charger or end device
When charge current over 10A, the fuse will be burnt.
When the rear output terminal or PoE output be short circuit, protection be active, the product stop output and auto-recover when the terminal back to normal connection.
The fuse will be burnt when battery output current over 10A
The output voltage on the rear terminal normally is the same as battery, if the battery voltage higher than 12.5V, the output voltage on the terminal will be clamped at 12.5V. The PoE output of TP-SCPOE-1212 with the same limit.
TP-SCPOE-12XX Series
RJ-45 Input (Data & Power) RJ-45 Output (Data & Power)
Pin Symbol Description Symbol Description
1 RX+ Data Receive RX+ Data Receive 2 RX- Data Receive RX- Data Receive 3 TX+ Data Transmit TX+ Data Transmit 4 (-Vdc)_return + 5 (-Vdc)_return + 6 TX- Data Transmit TX- Data Transmit 7 -Vdc Feeding power(-) -Vdc Feeding power(-) 8 -Vdc Feeding power(-) -Vdc Feeding power(-)
Feeding power(+) (-Vdc)_return + Feeding power(+) Feeding power(+) (-Vdc)_return + Feeding power(+)
Loading...