Tycon Power TP-MS324 User Manual

Page 1
USER’S MANUAL
TP-MS308/TP-MS316/TP-MS324
Power Source Equipment
(AC+DC Input, Gigabit PoE Midspan)
TYCON POWER SYSTEMS
Page 2
User’s Manual TP-MS308/316/324
2
3
3
4 4 4
4
5
5 6 6
7
14
15
15
16
17
18
19
20
22
23
24
26
27
28
29
30
31
Contents
1. Introduction...........................................................................
Features................................................................................................
Package Contents.................................................................................
2. Hardware Description...........................................................
Physical Dimension...............................................................................
Front Panel............................................................................................
LED Indicators.......................................................................................
Rear Panel............................................................................................
Power On..............................................................................................
Network Application...............................................................................
RJ-45 Remote Control Port...................................................................
3. Software Utility Installation..................................................
4. GUI Management...................................................................
Display and Illustration..........................................................................
System Login........................................................................................
Modify Password…...............................................................................
Edit Station TCP/IP...............................................................................
Edit Remote PoE IP.............................................................................
GUI Connect.........................................................................................
Station and Status Window Select .......................................................
Configuration.........................................................................................
Factory Setting…………........................................................................
Board Status………………………………………………………………… Port Status…………………………………………………………………... GUI Version………………………………………………………………….
GUI Disconnect…………………………………………………………......
File Open and Save…………………………………………………………
5. Technical Specification........................................................
Page 3
User’s Manual TP-MS308/316/324
3
1. Introduction
Tycons TP-MS308/TP-MS316/TP-MS324 is an AC+DC input, gigabit PoE Midspan (Power Sourcing Equipment), which injects power over data-carrying Ethernet cabling. The TP-MS308/TP-MS316/TP-MS324, support 8, 16 and 24 ports respectively in a 10/100/1000BaseT Ethernet network, over TIA/EIA-568 Category 5/5e/6 cabling. DC operating power, for data terminal units, is fed over data pairs C (4/5) and D (7/8) of the cabling. Remote management of up to 8 units via TCP/IP protocol is featured, which allows greater flexibility in the locating of network devices and significantly decreasing installation costs in many cases.
The TP-MS308/TP-MS316/TP-MS324 follows the IEEE 802.3af standard and is completely compatible with existing Ethernet switches and networked devices. This device normally powers PDs (Powered Devices) that are Power over Ethernet enabled or are equipped to receive power over Ethernet. The PSE tests whether a networked device is PoE-capable and power is never transmitted unless a Powered Device is at other end of the cable. It also continues to monitor the channel. If the Powered Device does not draw a minimum current, because it has been unplugged or physically turned off, the PSE shuts down the power to that port. Devices which are not equipped to receive power over Ethernet may require an external splitter in order to be powered. Contact TYCON for such a splitter.
Features
8/16/24 port Power Sourcing Equipment (PoE midspan) Support 8/16/24 ports full load, max. 134W/268W/403W IEEE802.3af compliance Remote power feeding of Ethernet terminals up to 100 meters Auto detect PD, and support manual detect PD Centralized power distribution for PoE powered Device (PD) Independent overload and short-circuit protection per channel Supports IEEE 802.3af non-standard device Auto refresh port status and support Plug and Play feature for PD Standard 19” or 23” rack mountable DIY upgrade from 8 port to 24 port available Remote manage up to 8 units via TCP/IP protocol DC input available, can work with battery, non-interrupt performance.
Page 4
User’s Manual TP-MS308/316/324
4
Package Contents
Unpack the contents of the TP-MS308/TP-MS316/TP-MS324 and verify them against the checklist below.
TP-MS308/TP-MS316/TP-MS324 x 1
Power Cord x 1 Bracket x 2 ( for 19 rack mounted) CD-ROM x 1 (Software Utility + User Manual)
Compare the contents of your TP-MS308/TP-MS316/TP-MS324 package with the standard checklist above. If any item is missing or damaged, please contact your local dealer for service.
2. Hardware Description
This Section mainly describes the hardware of the TP-MS308/TP-MS316/TP-MS324 and gives a physical and functional overview.
Physical Dimension
TP-MS308/TP-MS316/TP-MS324 physical dimension is: 430mm x 290mm x 44mm (Lx W x H) (1U,19 or 23 Rack mountable)
Front Panel
Figure 2-1. The Front panel of TP-MS308/TP-MS316/TP-MS324
The Front Panel of the TP-MS308/TP-MS316/TP-MS324 consists of 8/16/24 x RJ-45 Ethernet ports (data), 8/16/24 x RJ-45 PoE ports (data + power), 8/16/24 x LED port indicators, one LED power indicator and one RJ-45 remote control port (include one LED).
Page 5
User’s Manual TP-MS308/316/324
5
LED
Status
Color
Description
RJ45
On
Green
A network device is
detected(10/100/1000 Mbps)
but no communication activity is
detected
Blinking
Green
The Ethernet port is transmitting
to, or receiving package from
another device
Off
--
No device is detected
Power
On
Green
Power feeding normally
On
Red
Power or fan alarm
Off
--
Power off
Ports
On
Green
Power feeding
Blinking
Orange
Detecting
On
Orange
The port has been shutdown No power feeding
On
Red
Alarm No power feeding
Off
--
Unknown device attached No power feeding
LED Indicators
The LED Indicators gives real-time information of systematic operation status. The following table provides descriptions of LED status and their meaning.
Table 2-1. The Description of LED Indicators
Page 6
User’s Manual TP-MS308/316/324
6
Rear Panel
Figure 2-2. The Rear Panel of TP-MS308/TP-MS316/TP-MS324
The AC inlet, DC input terminal and 2 Ventilation fan are located at the rear panel of the TP-MS308/TP-MS316/TP-MS324. The device will work with AC in the range 100-240V AC, 50-60Hz. Or work with DC -48V(-42V~-57V).
Power On
Connect the power cord to the power socket on the rear panel of the PSE. The other side of power cord connects to the power outlet. The internal power supply of the PSE works with the voltage range of 100V-240VAC, frequency 50~60Hz, or with voltage range of DC -42V~-57V. Check the port, the power indicator will self-test on the front panel to see if power is properly supplied.
Network Application
The PSE can provide power to the PD which follow the IEEE 802.3af standard in the network. It can solve the problem of position limitation. The network device can be installed in a more appropriate position for better performance. The following figure is an example of a network application for PSE
Page 7
User’s Manual TP-MS308/316/324
7
RJ-45 Remote Control Port
TP-MS308/TP-MS316/TP-MS324 can remotely manage the PoE via the network. To manage TP-MS308/TP-MS316/TP-MS324, you must to set the TP-MS308/TP-MS316/TP-MS324 TCP/IP parameter. TP-MS308/TP-MS316/TP-MS324 allowed you to use a standard Web-browser such as Microsoft Internet Explorer or Mozila, to set the TCP/IP parameter.
Before you use the web interface to set the PoE TCP/IP, verify that TP-MS308/TP-MS316/TP-MS324 is properly installed on your network and PC on the network can access PoE via the web-browser.
1. Verify that PC network interface card (NIC) is operational on the TCP/IP protocol.
2. Supply power to TP-MS308/TP-MS316/TP-MS324.
3. Use RJ45 cable, connect TP-MS308/TP-MS316/TP-MS324 direct to your PC.
4. Make sure the TP-MS308/TP-MS316/TP-MS324 default IP is 192.168.1.10.
5. Set your PC IP to 192.168.1.2 or other IP address which is located in the
192.168.1.x subnet.
6. Make sure the connector is OK (Ping 192.168.1.10 on the DOS mode). 7 Start the web-browser and type http://192.168.1.10 (or used PoE IP setting icon in the PoE management software).
8. The login in screen will appear next.
Page 8
User’s Manual TP-MS308/316/324
8
9. Key in ID (user name) and password to enter PoE TCP/IP parameter setting. Default ID and password is admin and system.
10. TP-MS308/TP-MS316/TP-MS324 TCP/IP parameter has 4 pages interface (administrator setting, TCP Mode, UDP Mode and UART). You must change the administrator & TCP mode to fit your network.
Page 9
User’s Manual TP-MS308/316/324
9
11. Administrator setting: you can assign nickname, IP setting, user name, password and view system information.
Nickname: You can assign a name to the device. IP Address: You must assign the IP address reserved by your network. The default IP is 192.168.1.10. Subnet Mask: You can assign the subnet mask for the IP address. The default subnet mask is 255.255.255.0. Gateway: You can assign the gateway here. The default gateway is 192.168.1.1. IP Configure: You must assign to Static for PoE serve operation. The default IP configure is Static. Username: You can assign new user name. The default setting is admin. Password/Confirm: You can type in new password here. The default setting is system.
When you have finished the set up, click on Update to update your setting.
Page 10
User’s Manual TP-MS308/316/324
10
12. TCP Mode: You can update the TCP control parameter here.
Telnet Server/Client: Set to Server for PoE management operation. Port Number: You can assign port number for TCP/IP operation. The default Port Number is 23. Remote Server IP Address: Unused. Clint mode inactive timeout: Unused. Server mode protect timeout: Set to 0(Disable) for normal operation.
When you have finished the set up, click on Update to update your setting.
Page 11
User’s Manual TP-MS308/316/324
11
13. UDP Mode: This mode is not used in the PoE application.
Page 12
User’s Manual TP-MS308/316/324
12
14. UART: You must set UART Control to RS232,9600,8,N,1 for PoE operation.
Mode: Set to RS232 for PoE operation. Baud rate: Set to 9600 bps for PoE operation. Character Bits: Set to 8 bits for PoE operation. Parity Type: Set to none parity for PoE operation. Stop Bit: Set to 1 stop bit for PoE operation. Hardware Flow Control: Set to none flow control for PoE operation.
When you have finished the set up, click on Update to update your setting.
Page 13
User’s Manual TP-MS308/316/324
13
15. When you have configured your set up, you must reset the device to take effect.
Page 14
User’s Manual TP-MS308/316/324
14
3. Software Utility Installation
Before you start to remote configure the PD, please install the software utility. Through the software utility, you can easily to control the PD which connects with PoE and view the PD parameter information. The software utility provides GUI interface and it is easy to install. The software utility supports Windows environment – Window 98, 2000, XP, Vista and Window 7. Please follow the below steps to install the software utility.
1. Insert the software utility CD-ROM into your CD-ROM drive.
2. Run the “setup.exe”.
3. You will see the installation screen display.
4. Then, click the “Next” button to go next step.
Page 15
User’s Manual TP-MS308/316/324
15
4. GUI Management
Display and Illustration
Connect the PSE with a PC through the remote control port. Then, run the software utility (Netclient). You will see the main utility interface below.
Tools bar PSE station selection & alarm indicator legend tool
Display page select PSE port select
PSE station TCP/IP setting message window
TCP/IP edit/view icon PSE TCP/IP setting TCP/IP connection indicator Change web-browser icon
Page 16
User’s Manual TP-MS308/316/324
16
System Login
Run the management software or click File, and select Login, the system will show the diagram below.
Now enter the password, first enter the default setting which is 0000
Page 17
User’s Manual TP-MS308/316/324
17
Modify Password
Click File and select Modify PSW, you can modify the password, the system permits 3 sets of password.
Page 18
User’s Manual TP-MS308/316/324
18
Edit Station TCP/IP
In the TCP/IP Status display window, you can edit the station name, TCP/IP address and port number. Click the Edit icon to modify this parameter. In the Edit window, click the View icon to display TCP/IP parameter.
Station Name: You can assign a name to the PSE device. Address: You can assign the IP address for this PSE station. Port:: You can assign the port number for this PSE station.
Page 19
User’s Manual TP-MS308/316/324
19
Edit Remote PoE IP
In the TCP/IP Status display window, you can use PoE IP Setting icon to start the web-browser. To modify the remote PoE TCP/IP parameter, please reference RJ-45 Remote Control Port of section 2 Hardware Description (page 7).
Change Browse icon: You can use this icon to change the web-browser for remote PoE IP edit. The default web-browser is Microsoft Internet Explorer.
Page 20
User’s Manual TP-MS308/316/324
20
GUI Connect
In the TCP/IP Status display window, edit TCP/IP parameter, then click GUI and select Connect All command or click connect icon, if the Station Select window shows the name icon and displays power status(green or red) light, it means that the PSE connection is correct. You can then select station to configure you PSE.
Page 21
User’s Manual TP-MS308/316/324
21
GUI connect example: In the Station Selection window, the LED indicates real time connection of PSE. Green-----this connection and PSE power are normal. Red--------this connection is OK but PSE power is not correct. Orange---this connection is not working.. Gray-------this station is not setting.
In the TCP/IP Status window, the LED indicates real time status of TCP/IP. Green-----TCP/IP connection is OK. Red--------TCP/IP connection is not working. Gray-------TCP/IP parameter is not setting.
Page 22
User’s Manual TP-MS308/316/324
22
Station and Status Window Select
The PSE management software can monitor 8 PSE simultaneously. In the GUI Disconnect mode, only the TCP/IP Status display window can be used to set the TCP/IP parameter. In the GUI Connector mode, there three display windows can choose ­TCP/IP Status/Port Status/Board Status. Port status and Board Status show relative PSE Station status. If you want to change the status display window, only use the mouse to choose the relative word icon. If you want to change the station, also use the mouse to choose the station name icon.
Station Select display icon Status display icon
Page 23
User’s Manual TP-MS308/316/324
23
Configuration
In the Module window, select the suitable port that you require, then, click Config, and select Setup, the screen will show the system control panel as below.
Set icon: Apply the operation mode to PSE system. Set Enable/Set Disable icon: Change the Board Status window to set enable/disable. Factory icon: Apply the factory setting to PSE system.
You can setup Operation Mode/ AC Disconnect/ DC Disconnect of each port individually, then, click Set.
PSE port operates in one of three modes: auto mode, force mode and shutdown mode. In auto mode, the port will detect and classify a PD to connect to, then immediately turn on the power if the detection was successful. In force mode, the port will not detect and classify a PD to connect to, but immediately turn on the power to the port. In shutdown mode, the port is disabled and does not detect or power on a PD.
Page 24
User’s Manual TP-MS308/316/324
24
Factory Setting
Click Config, and select Factory or click the Factory icon. The screen will show the factory setting control panel as below:
then click Y for the Factory Setting.
Page 25
User’s Manual TP-MS308/316/324
25
Factory setting as below: Operation Mode Auto (Auto, Force & Shutdown) AC Disconnect On (On & Off) DC Disconnect Off (On & Off)
Page 26
User’s Manual TP-MS308/316/324
26
Board Status
Click Config, and select GetBoardStatus, or click Board STATUS icon, the screen will show current status of each port.
Page 27
User’s Manual TP-MS308/316/324
27
Port Status
In the Module window, select the suitable port that you require, then, click StatusDisp, and select PortStatus, or click the PORT STATUS icon, the screen
will show current status of each port and current power supply status of each module.
If all power modules are working normally, the Sys. Power will show a green light, if any module has failed, the light will turn to red.
Page 28
User’s Manual TP-MS308/316/324
28
GUI Version
Click StatusDisp, and select GUI Version, the screen will show the version of the EMS utility
Page 29
User’s Manual TP-MS308/316/324
29
GUI Disconnect
Click the GUI, and select Disconnect All, or click the GUI disconnect icon to disconnect the communication between GUI and PSE.
Page 30
User’s Manual TP-MS308/316/324
30
File Open and Save
You may click File and select Open, or click the Open file icon, to open the previous setting file. Click Save, or Save file icon, to save the current setting.
Page 31
User’s Manual TP-MS308/316/324
31
PARAMETER
TP-MS308
TP-MS316
TP-MS324
Data Ports
8
16
24
PoE Ports
8
16
24
Pass through Data Rates
10/100/1000Mbps
Console Port
1× RJ45 console interface for management
Output power
Per port DC 48V@350mA 16.8W(Maximum)
Pair4/5(+),Pair7/8(-)
Disconnection
AC Disconnect
(AC Disconnect and DC Disconnect display the detect
scheme being used and are for information only)
Power consumption
(maximum)
134W
268W
403W
AC Input
100~240VAC,50/60Hz
DC Input
DC -48V(-42V~-57V)
Environment
Operating Temperature: 0℃~65 Storage Temperature: -20℃~80
Humidity: 10%~95%RH (non condense)
Dimensions
430mm(L) x 290mm(W) x 44mm(H), 19” Rack-Mount / 1U
Weight
3.2kg
3.9kg
4.6kg
5. Technical Specification