Typical applications
Car alarm, hazard warning signal, heated rear screen, immobilizer, lamps
front/rear, fog light, interior lights, sun roof, turn signal, wiper control.
F072A/C_fcw2b
Contact Data
Load resistive/inductive resistive/inductive resistive/inductive head/indicator head/indicator
load load load lamp lamp
V23072-C10**-A302 V23072-C10**-A303 V23072-C10**-A308 V23072-C1061-A402 V23072-C1061 A408
Contact arrangement 1 form A, 1 NO 1 form C, 1 CO 1 form U/X, 2 NO 1 form A, 1 NO 1 form U/X, 2 NO
Rated voltage 12VDC 12VDC 12VDC 12VDC 12VDC
Rated current 15A 10/15A 2x10A 12A 2x6A
Limiting continuous current
23°C 15A 10/15A 2x10A 12A 2x6A
85°C 10A 5/10A 2x6A 10A 2x5A
Limiting making current
Limiting breaking current 20A 10/20A 2x20A 6A 12A
Contact material AgNi0.15 AgNi0.15 AgNi0.15 AgSnO.2 AgSnO.2
Min. recommended contact load
Initial voltage drop at 10A, typ./max. 50/300mV 50/300mV 2x50/300mV 150/300mV
150/300mV
Operate/release time max. typ. 3/1.5ms
Electrical endurance >2x105 ops. >2x105 ops. >2x105 ops. >1x106 ops. >1.5 x 106 ops.
at 13.5VDC, 10A at 13.5VDC, 10A at 13.5VDC, 10A up to 6x21W up to 6x21W
>1.5x10
100A (on), 10 A (off) 100A (on), 10A (off)
high beam high beam
1) The values apply to a resistive load or inductive load with suitable spark suppression and at maximum 13.5VDC for 12VDC and 27VDC for 24VDC load voltages.
2) For a load current duration of maximum 3s for a make/break ratio of 1:10.
3) Corresponds to the peak inrush current on initial actuation (cold filament).
4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes
5) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher
risk of contact tack welding (monostable version only).
1)2)
60A NC/NO 12/60A 2x40A 60A3) 120A3)
4)
1A at 5VDC 1A at 5VDC 1A at 5VDC 1A at 5VDC 1A at 5VDC
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Load limit curve 1: safe shutdown, connected as form X, load on pin 5 and 7.
Load limit curve 2: safe shutdown, no stationary arc (NO contact).
Load limit curve 3: arc extinguishes during transit time (CO contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
1
Page 2
Automotive Relays
Does not take into accountthe temperature rise due tothe contact currentE = pre-energization
TE1111-U1
TE1077-B1
TE1116-11
PCB Relays
Mini Relay K (Open – Sealed) (Continued)
Coil Data
Rated coil voltage 12VDC, 24VDC
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10% W
061 12 6.9 1.2 130 1.1
062 24 14.1 2.4 520 1.1
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil operating range
Other Data
EU RoHS/ELV compliance compliant
Degree of protection
IEC 61810 RT II – open (V23072-A),
RT III – imm. cleanable (V23072-C)
Climatic cycling with condensation
EN ISO 6988 20 cycles, storage 8/16h
Temperature cycling (shock)
IEC 60068-2-14, Na 720 cycles, -40/+85°C (dwell time 1h)
Damp heat constant
IEC 60068-2-3, Ca 56 days, upper air temperatue 55°C
Corrosive gas
IEC 60068-2-42 10 days
IEC 60068-2-43 10 days
Vibration resistance (functional)
IEC 60068-2-6 (sine sweep), 10 to 200Hz, 23 to 35g
Shock resistance (functional)
IEC 60068-2-27 (half sine), 4 to 6ms 23 to 280g
Terminal type PCB
Weight, open/sealed approx. 8/9g (0.28/0.32oz)
Solderability (aging 3: 4h/155°C)
IEC 60068-2-20 Ta, method 1, hot dip 5s, 215°C
Sealing, IEC 60068-2-17 Qc, method 2, 1min/70°C
Storage conditions according IEC 600688
Packaging unit
open 600 pcs.
sealed 504 pcs.
6) Values weekest direction. Depending on mounting position: no change in the switching
state >10μs.
7) For general storage and processing recommendations please refer to our Application
Notes and especially to Storage in the Definitions or at http://relays.te.com/appnotes/
6)
6)
7)
Does not take into account the temperature rise due to the contact current
E = pre-energization.
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
3
tion, application notes and all specifications
are subject to change.
Page 4
Automotive Relays
PCB Relays
Mini Relay K (Open – Sealed)
Product code structure Typical product code V23072 -A 1 061 -A 30 2
Type
V23072 Mini Relay K (Open – Sealed)
Terminal and enclosure
A PCB, open (RT II) C PCB, sealed (RT III – immersion cleanable)
Design
1 Standard
Coil
061 12 VDC 062 24 VDC
Contact type
A Standard
Contact material
30 AgNi0.15 40 AgSnO
Contact arrangement
2 1 form A, NO 3 1 form C, CO 8 1 form U/X, 2 NO
2
(Continued)
Product codeTerminal/Encl. DesignCoilContact type Cont. material Arrangement Part number
Datasheets and product specification according to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ section, application notes and all specifications
are subject to change.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.