Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
Features
1 C/O or 1 N/O or 2 C/O contacts
4 kV / 8 mm coil-contact
Reinforced insulation (protection class II)
Height 15.7 mm
transparent cover optional
Applications
Domestic appliances, heating control, emergency lighting
VZ
Approvals in process
Contact data
Configuration 1 C/O or 1 N/O 2 C/O Type of contact single contact Rated current 12 A 16 A 8 A Rated voltage / max.breaking voltage AC
250 Vac / 440 Vac Maximum breaking capacity AC 3000 VA 4000 VA 2000 VA Contact material AgNi 90/10
Coil data
Nominal voltage DC coil 5...110 Vdc
AC coil 24...230 Vac
Nominal coil power DC coil 500 mW
AC coil 0.75 VA
Operate category 2
Coil versions, DC-coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vdc Vdc Vdc Vdc c mA
005 5 3.5 0.5 9.8 50+5% 100.0 006 6 4.2 0.6 11.8 68+5% 87.7 012 12 8.4 1.2 23.5 274+5% 43.8 024 24 16.8 2.4 47.0 1095+5% 21.9 048 48 33.6 4.8 94.1 4380+5% 11.0 060 60 42.0 6.0 117.6 6845+5% 8.8 110 110 77.0 11.0 215.6 23010+5% 4.8
All figures are given for coil without preenergization, at ambient temperature +20°C Other coil voltages on request
1pole
Page 2
Rights to change data / design reserved
Edition: 10/2003
Insulation
Dielectric strength coil-contacts 4000 V
rms
open contact circuit 1000 V
rms
Clearance / creepage 8 / 8 mm Insulation to IEC 60664
Voltage rating 250 V Pollution degree 3 Overvoltage category III
Insulation dimensions
coil-contacts reinforced insulation contact-contact basic / functional insulation across open contacts micro-disconnection
Tracking resistance of relay base CTI 250
Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
Coil versions, AC-coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vac Vac Vac Vac c mA 524 24 18.0 3.6 36.0 350+10% 31.6 615 115 86.3 17.3 172.5 8100+15% 6.6 730 230 172.5 34.5 345.0 32500+15% 3.2
All figures are given for coil without preenergization, at ambient temperature +20°C
Other data
Flammability class according to UL 94
standard / transparent cover V-0 / HB Coil insulation system according to UL 1446 Class F Min. ambient temperature -40 °C Max. ambient temperature / mounting distance 1pole 2pole
DC-coil 85 °C
1)
/ 2.5 mm 70 °C / 2.5 mm
AC-coil 70 °C / 2.5 mm 70 °C / 5 mm Mechanical life
DC-coil >5x106operations
AC-coil >1x106operations Max. switching rate at rated- / minimum load 6 min-1/ 600 min
-1
Operate- / release time DC-coil typ. 7 / 2 ms Bounce time N/O contact/N/C contact typ. 1 / 3 ms Vibration resistance N/O 20 g, 10...150 Hz Shock resistance (destruction) 100 g Category of protection (IEC 61810) RT II - flux proof, RT III - wash tight
2)
Relay weight 13 g Packaging unit 500 pcs.
1)
version with transparent cover: 70°C
2)
version with transparent cover: RTII only
Page 3
Edition: 10/2003
Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A) DC or AC-coil
PCB layout / terminal assignment
1 pole 12 A
S0418-BB
S0163-BG
S0163-BH
1 pole 16 A
S0418-BA
S0163-BE
S0163-BF
Rights to change data / design reserved
S0418-BA
S0163-BJ
2 pole 8 A
Dimensions
Dimensions in mm
S0272-AA
View on solder pins Dimensions in mm
*) With the recommended PCB hole sizes a grid pattern from 2.5 mm to 2.54 mm can be used.