Rights to change data / design reserved
Edition: 10/2003
Insulation
Dielectric strength coil-contacts 4000 V
rms
open contact circuit 1000 V
rms
Clearance / creepage 8 / 8 mm
Insulation to IEC 60664
Voltage rating 250 V
Pollution degree 3
Overvoltage category III
Insulation dimensions
coil-contacts reinforced insulation
contact-contact basic / functional insulation
across open contacts micro-disconnection
Tracking resistance of relay base CTI 250
Power PCB Relay RX
1 pole (12 or 16 A) or 2 pole (8 A)
DC or AC-coil
Coil versions, AC-coil
Coil Nominal Pull-in Release Maximum Coil Coil
code voltage voltage voltage voltage resistance current
Vac Vac Vac Vac c mA
524 24 18.0 3.6 36.0 350+10% 31.6
615 115 86.3 17.3 172.5 8100+15% 6.6
730 230 172.5 34.5 345.0 32500+15% 3.2
All figures are given for coil without preenergization, at ambient temperature +20°C
Other data
Flammability class according to UL 94
standard / transparent cover V-0 / HB
Coil insulation system according to UL 1446 Class F
Min. ambient temperature -40 °C
Max. ambient temperature / mounting distance 1pole 2pole
DC-coil 85 °C
1)
/ 2.5 mm 70 °C / 2.5 mm
AC-coil 70 °C / 2.5 mm 70 °C / 5 mm
Mechanical life
DC-coil >5x106operations
AC-coil >1x106operations
Max. switching rate at rated- / minimum load 6 min-1/ 600 min
-1
Operate- / release time DC-coil typ. 7 / 2 ms
Bounce time N/O contact/N/C contact typ. 1 / 3 ms
Vibration resistance N/O 20 g, 10...150 Hz
Shock resistance (destruction) 100 g
Category of protection (IEC 61810) RT II - flux proof, RT III - wash tight
2)
Relay weight 13 g
Packaging unit 500 pcs.
1)
version with transparent cover: 70°C
2)
version with transparent cover: RTII only