tyco HS2TCH User Manual

To download the full user manual and register your product, please visit: www.dsc.com/m/29010319 or scan the QR code to the right.
HS2TCHPRO/HS2TCHPROBLK Touchscreen User Guide
Ecran tactile HS2TCHPRO/HS2TCHPROBLK Mode d'emploi
Pantella de Toque HS2TCHPRO/HS2TCHPROBLK Guía del
Usuario
Tela de Toque HS2TCHPRO/HS2TCHPROBLK Guía de Usuario
WARNING: This manual contains information on li mitations regarding product use, function and information
MISE EN GARDE: Ce manuel contient des informations sur les limitations concernant l’utilisation et le fonc­tionnement du produit ainsi que des informations sur les limitations et les obligations du fabricant Lisez attent­ivement le guide complet.
AVISO: Este manual contiene información sobre limitaciones referentes a la utilización y al funcionamiento del producto e información sobre las limitaciones de las responsabilidades del fabricante. Todo el manual debe leerse atentamente.
ADVERTÊNCIA: Este manual contém informações sobre limitações em relação ao uso e funcionamento do produto, bem como informações sobre as limitações de responsabilidade do fabricante. Todo o manual deve ser lido com atenção.

Safety Notes

Safety Notes
This manual shall be used in conjunction with the PowerSeries Pro User manual for the compatible alarm control panel: HS3032, HS3128, HS3248.
Always ensure you obtain the latest version of the User Guide. Updated versions of this User Guide are available by contacting your distributor.
Warning: Read and save these instructions! Follow all warnings and instructions specified within this document and/or on the equipment.

Important Safety Instructions

To reduce the risk of fire, electric shock and/or injury, observe the following:
l Do not spill any type of liquid on the equipment. l Do not attempt to service this product yourself. Opening or removing the cover may expose you to dan-
gerous voltage or other risk. Refer servicing to qualified service personnel. Never open t he device your­self.
l Do not touch the equipment and its connected cables during an electrical storm; there may be a risk of
electric shock.
l Do not use the Alarm System to report a gas leak if the system is near a leak.

Regular Maintenance and Troubleshooting

Keep your HS2TCHPRO/HS2TCHPROBLK Touchscreen keypad in optimal condit ion by following all the instruc­tions that are included within this manual and/or marked on the product.

Handling Precautions

Do not apply excessive force to t he display surface or the adjoining areas since this may cause the color tone to vary.

Cleaning

l If the display surface is contaminated, breathe on the surface and gently wipe it with a soft, dry cloth. If
still not completely clean, moisten cloth with isopropyl alcohol.
l Do not use abrasives, water, thinners, solvents or aerosol cleaners (spray polish), any aromatic solvents,
ketones etc. that may enter through holes in the HS2TCHPRO/HS2TCHPROBLK Touchscreen keypad and cause damage.

Troubleshooting

Occasionally, you may have a problem with your system. If this happens, your Alarm Controller will display an error message. Refer to the provided list when you see an error message on the display. If additional help is required, contact your distributor for service.
Warning: This equipment, HS2TCHPRO/HS2TCHPROBLK Touchscreen keypad shall be install ed and used within an environment that provides the pollution degree max 2 and over-voltages category II non-hazardous loc­ations, indoor only. It is designed to be i nstalled, serviced and/or repaired by service persons only [service person is defined as a person having the appropriate technical training and experience necessary to be aware of hazards to which that person may be exposed in performing a task and of measures to minimize the risks to that person or other persons]. There are no parts replaceable by the end-user within this equipment.
Warning: Never obstruct the access to the Alarm controller to which this equipment is connected. These safety instructions should not prevent you from contacting the distributor and/or the manufacturer to obtain any further clarification and/or answers to your concerns.
- 2 -

Quick Start

Description: Arms all interior and exterior sensors
Away Arm
Stay Arm
Disarm
Bypass
View Alarms
View Troubles
Perform System Test
Set Time/Date
Turn Chime On/Off
Change screen brightness
Change Buzzer Volume
Method: Press anywhere on the top banner of the home page
Indications:
Description: Arms all exterior sensors. Does not arm interior sensors Method: Press Stay Arm button Indications: Description: Deactivates all interior and exterior sensors Method: Press anywhere on the top banner of the home page Indications: Description: Excludes selected zones from activating the alarm when the system is armed
Method:
Indications: The Bypass button changes to Unbypass
Description: View which zones have triggered alarms Method: Press the ! button (visible if an alarm has occurred) Indications: The ! button is displayed at the top, right side of the screen Description: View system troubles Method: Press the ! button (visible if an alarm has occurred) Indications: The ! button is displayed at the top, right side of the screen Description: Tests the keypad sounder, siren, status lights and backup battery Method: Options + User Functions + [Access Code] + System Test
Indications:
Description: Adjusts the t ime and date displ ayed on the home page
Method:
Indications: Changes are displayed in t he top, right corner of the home page Description: Turns the door chime function on/off Method: Press Chime
Indications:
Description: Adjusts the brightness and contrast of the touchscreen
Method:
Indications: Screen brightness adjusts as the slider is moved Description: Adjusts the l evel of the keypad buzzer
Method:
Indications: The buzzer beeps at the selected volume level
Quick Start
Arming
The Armed ( ) LED lights. Top banner turns red and displays “Armed”. Exit delay timer starts.
Armed ( ) LED lights. Top banner turns red and displays “Armed”
Ready ( ) LED light s. Top banner turns green and displays “Disarmed”
Press Zone Bypass to display available zones, then press the Bypass button beside a zone
Common Functions
Sounder and siren activate for 2 seconds, all lights turn on, Ready, Armed and Trouble lights flash for duration of test
Options + User Functions + [access code] + Time & Date. Press the section you want to change (e.g., Hrs) then use the arrow keys to change the value. Press Save
On: sounder emits 3 short beeps. Chime icon displays a checkmark. Off: sounder emits 1 long beep. Chime icon displays an X.
Options + User Functions + [Access Code] + Keypad Config + Display Options
Use the sliders to increase or decrease the screen brightness
Options + User Functions +[Access Code] + Keypad Config + Buzzer Control
Use the slider to increase or decrease the buzzer volume
- 3 -

Introducti on

Introduction
Figure 1- Controls and Indicators
The HS2TCHPRO/HS2TCHPROBLK Touchscreen is an interactive touch-sensitive color LCD that can be used on any PowerSeries Pro control panel. Due to the custom requirements of individual installations, some of the fea­tures described here may perform differently than described. Refer to your Installer's Instructions for the details of your specific installation and to the User Manual for general security system information.

Testing

To ensure that your system continues to function as intended, you must test it weekly. Please refer to the “Testing your System” section in this manual. If your system does not function properly, call your installing company for service.

Monitoring

This system is capable of transmit ting alarms, troubles and emergency information to a central station. If you ini­tiate an alarm by mistake, immediately call the central station to prevent an unnecessary response.

Using Your System

This section provides additional information about how to use your alarm system.

When Alarm Sounds

The system can generate 3 different alarm sounds:
l Temporal/pulsed siren = Fire Alarm
l 4 beeps, 5-second pause, 4 beeps = Carbon Monoxide Alarm
l Conti nuous si ren = Intrusion (Burglary Al arm)
Note: The priority of signals is fire alarm, carbon monoxide alarm and medical alarm, then burglary alarm.
Note: Medical alarm is silent. It only results i n an alarm transmission to the monitoring station.

Intrusion (Burglary) Alarm Continuous Siren

If you are unsure of the source of the alarm, approach with caution! If the alarm was accidental, enter your Access Code to silence the alarm. Call your central station to avoid a dispatch.
- 4 -
Introducti on

If the Intrusion Alarm was Accidental

1. Enter your Access Code to silence the alarm. If the code is entered wit hin 30s (or the programmed value of the alarm transmission delay) the transmission of the alarm to the monitoring station will be canceled.
2. Call your central station t o avoid a dispatch.

Fire Alarm Pulsed Siren

Follow your emergency evacuation plan immediately!
If the fire alarm was accidental (e.g., burned toast, bathroom steam, etc.), enter your Access Code to silence the alarm. Call your central station to avoid a dispatch. To reset the detectors, see the Sensor Reset section.

Wireless Carbon Monoxide Alarm

Activation of your CO alarm indicates the presence of carbon monoxi de (CO), which can be fatal. During an alarm, the red LED on the CO detector flashes rapidly and the buzzer sounds with a repeating cadence of: 4 quick beeps, 5-second pause, 4 quick beeps. Also, during an alarm, the siren connected t o the control panel produces a repeat­ing cadence of 4 quick beeps, 5-second pause, 4 quick beeps. The keypad will also provide audi ble and visual indication of the CO alarm.
If an Alarm Sounds:
1. Operate silence button.
2. Call emergency services or your fire department.
3. Immediately move outdoors or to an open door/window.
Warning: Carefully review your Carbon Monoxide Installation/User Guide to determine t he necessary actions required to ensure your safety and ensure that the equipment is operati ng correctly. Incorporate the steps outlined in the guide into your evacuation plan.
- 5 -

Troubles

Troubles
When a trouble condition is detected, the Trouble (!) or System indicator will turn on, and the keypad will
beep every 10 seconds. Press the (!) key to silence the beeps. Press (!) to view the trouble condition. The
Trouble (!) or System indicator will flash. The corresponding trouble will light up.
Troubles Comments Action
Service Required (Press for more details)
AC Loss
Phone Trouble The system has detected that the telephone line is disconnected.
Communication
Failure
Zone Fault
Zone Tamper
Wireless Low Battery
Loss of Clock
Limit Exceeded
Low Battery General System Supervision
Bell Circuit RF Jam Detected
General System Trouble Panel Low Battery
General System Tamper Panel AC Loss
If the building and/or neighborhood has lost electrical power, the system will continue to operate on battery for several hours.
The system attempted t o communicate with the monitoring station, but fail ed. This may be due to Telephone Line Fault.
The system is experiencing difficulties with one or more sensors on the system. Press to display the zone.
The system has detected a tamper condition with one or more sensors on the sys­tem. Press to display the zone.
The system has detected a low battery condition with one or more mod­ules/sensors on the system. Press to display the zone, keypad, wireless key(s) and RF Delinquency low battery condit ions. Press again to see zone troubles.
If complete power was lost (AC and Battery), the time and date will need to be reprogrammed.
[01] Interactive zone: The number of zones configured in the panel i s not sup­ported by ADC firmware (e.g.:>220)
[02] Interactive partition: The number of partitions configured is not supported by ADC firmware (e.g.:>8)
Call for
service
Call for
service
Call for
service
Call for
service
Call for
service
Call for
service
Call for
service
Reprogram
Time &
Date

Additional Functions

Photos

You can create a slideshow of photos to View on the keypad. Photos are added using an SD card (32x24x2.1 mm. Not supplied). See online user manual for details.

Quick Exit

If the system is armed and you need to exit, use the quick exit function t o avoid disarming and rearming the sys­tem. To activate this function, tap the Quick Exit icon. You have 2 minutes to leave t he premises through your exit door. When the door is closed again the remaining exit time is canceled.
- 6 -

Options Menu

Time & Date Programming

Tap on Options. Select User Functions [Master Code] and then select Time & Date. Tap on the section you would like to change and use the up/down arrows to change t ime/date. Once done, press Save.

Keypad Mode

This option allows the HS2TCHPRO/HS2TCHPROBLK Touchscreen to function as a traditional DSC keypad.

Door Chime (Chime enable/disable)

The keypad indicates the current state of the door chime function (Enabled or Di sabled). To choose t he opposite function, tap t he 'Chime' icon. Three beeps indicate that t he chime is ON (Enabled). One long beep indicates that chime is OFF (Disabled).
Note: The door chime feature should be used in Disarmed mode only.

Zone Bypass

This screen allows you to view the status of the zones on the syst em.

Zone Status Indicators

Ready Zone is closed
Open The zone is open and needs to be closed
Options Menu
Access the following functions by pressing Options on the right side of the home page. See the online HS2TCHPRO/HS2TCHPROBLK User Manual for more information.
l Access Codes
l Installer Menu
l User Functions
l Chime Enabled/Disabled
l Partition Status
l Keypad Mode

Access Codes

For more information, see the online HS2TCHPRO/HS2TCHPROBLK User Manual.

User Functions

Access the following user functions by pressing Options + User Functions + [Access Code]. For more information, see the online HS2TCHPRO/HS2TCHPROBLK User Manual.

Keypad Configuration

The following options can be configured:
Display Options: sets the brightness and screen timeout of the Touchscreen, as well as screen saver options.
Buzzer Control: sets the buzzer volume of the Touchscreen. Note: For SIA CP-01, the buzzer volume shall not
be placed at the minimum setting.
Note: For UL/ULC installations, the buzzer level shall not be changed from the default level.
- 7 -

Emergency Keys

Picture Frame: selects the pictures that will be displayed on the slideshow.
Calibration: calibrates the Touchscreen.
Clock Mode: displ ays the digital clock.
Clean Mode: allows the user to touch (i.e., clean) the screen without enabling or disabling any functions. The
screen will remain in this mode for 30 seconds, then return to the Keypad Configuration screen.
Home Page: can be configured in one of two di fferent views, Classic (square buttons) and Contemporary
(rondel).

Chime Enabled/Disabled

Door Chime: To turn the door chime function On/Off, tap the Chime icon. 3 beeps indicate that the chime is
ON. 1 long beep indicates the Chime is OFF.

Partition Status

To view the partition status, press Options, User Functions, then Partiti on Status. The keypad shows basic status for up to 8 partitions, depending on the configuration of your system. Each partition is identified along with its current status.

Keypad Mode

This option allows the HS2TCHPRO/HS2TCHPROBLK Touchscreen to function as a traditional DSC keypad.
Emergency Keys
When the emergency key is pressed, a new screen i s displayed with:
Fire Fire Assistance Required. Press and hold for 2 seconds t o activate.
Medical Medical Assistance Required. Press and hold for 2 seconds to activate.
Panic Police Assistance Required. Press and hold for 2 seconds to activate.
Important: The Medical and Panic keys are ON by default. The Fire key will not function unless programmed by the Installer. Please ask your installer if the Fire, Medical and Panic keys are enabled.
- 8 -

Testing Your System

Testing Your System
Note: If you are going to perform a System Test , call your Monitoring Station to inform them when you begin and also when you end the test.

Testing Your Keypad Sounder and Siren

The System Test performs a two-second check of the keypad sounder and bell or siren, in addition to testing the keypad status lights and the panel backup battery.
1. Press Options, User Functions [Master Code], then System Test. The following will occur:
- The system activates all keypad sounders and bells or sirens for 2 seconds. All keypad light s turn ON.
- The Ready, Armed, and Trouble LEDs will flash for the duration of the test.
2. To exit the function menu, press [#].

Testing Your Entire System

All smoke detectors in this installation must be tested by your smoke detector installer or dealer once a year to ensure they are functioning correctly.
Note: Should the system fail to function properly, call your installation company for service immediately.
1. Prior to testing, ensure that the system is disarmed and the Ready l ight is on.
2. Close all zones to return t he system to the Ready state.
3. Perform a System Test by following the steps in the “Testing Your Keypad Sounder and Siren” section.
4. To test t he zones, activate each detector in turn (e.g., open each door/window or walk in motion detector areas).
On an HS2TCHPRO/HS2TCHPROBLK keypad, the following message will be displayed when each zone
(detector) is activated: “Ready to Force,” “Not Ready”. Use the zone status button t o view whi ch zones are open. The message will disappear when the zones are closed.
Note: Some features described above will not be functional unless enabled by your installer. Ask your installer which features are functional on your system.

Walk Test Mode

The installer can initiate a Walk Test mode for the system. While in Walk Test mode, the Ready, Armed, and Trouble LEDs will flash to indi cate that Walk Test is active. When the system automatically terminates the Walk Test mode, it will annunciate with an audible warning (5 beeps every 10 seconds), beginning five minutes prior to the t ermination of the t est.
- 9 -

License Agreement

IMPORTANT - READ CAREFULLY: DSC S oftware purchased w ith or w ithout Products andComponents is copyrighted and is purchased under the following license terms:
- This End-User License Agreement (“EULA” ) i s a l egal agreement between You (the c ompany, individual or entity who acquired the Software and any related Hardware) and Digital Security Controls, a division of Tyco S afety P roducts Canada Ltd. (“DSC”), the manufacturer of the integrated security systems and t he developer of the soft­ware and any related products or components (“HARDWARE”) which You acquired.
- If the DS C s oftware product (“S OFTWARE P RODUCT” or “S OFTWARE”) is intended to be accompanied by H ARDWARE, and is NOT accompanied by new HARDWARE, You may not us e, copy or install the SOF TWARE PRODU CT. The S OFTWARE PRODUCT includes computer software, and may i nclude ass ociated media, printed materials , and “online” or electronic documentation.
- A ny s oftware provided along with the S oftware P roduct that is associated with a s eparate end-user license agreement is licensed to You under the terms of that license agreement.
- By install ing, copying, downloading, s toring, acces sing or otherwis e using t he S oftware Product, Y ou agree unconditionally to be bound by the terms of this EU LA, even if this EULA is deemed to be a modification of any previous arrangement or contract. If You do not agree to the terms of this EULA , DS C is unwilling to license t he S oft­ware Product to You, and You have no right to use it.
SOFTWARE PRODUCT LICENSE
The S OFTWARE PRODUCT is protected by copyright laws and i nternational copyright treaties, as well as other i ntellectual property laws and treaties . The SOFTWARE PRODUCT is licensed, not sold.
1. GRANTOFLICENSE This EULA grants You the followingrights:
(a)Software Install ation and Us e - For each license Y ou acquire, You may have only one copy of the SO FTWARE P RODUCT i nstalled.
(b)Storage/Network U se - The SO FTWARE P RODUCT may not be i nstalled, access ed, displayed, run, s hared or used concurrently on or from different computers, includ­ing a w orkstation, t erminal or other digital e lectronic device (“Device”). In other w ords, if You have several w orkstati ons, You will have to acquire a license for each workstation where the SO FTWARE w ill be used.
(c)Backup Copy- Y ou may make back-up copies of the SOF TWARE PRODUCT, but You may only have one copy per l icense inst alled at any given time. You may use the back-up copy s olely for archival purposes. Except as expressly provided in this EULA, You may not otherwise make copies of the S OFTWARE PRODUCT, including the printed materials accompanying the SOF TWARE.
2. DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS
(a) Limita tions on Reverse Engineering, Decompilation and Dis ass embly - You may not reverse engineer, decompile, or disass emble the SOF TWARE PRODUCT, except and only to the extent that s uch act ivity i s expressly permitted by applicable law notwithstanding this l imitation. You may not make any changes or modifications to the Software, wit hout the written permiss ion of an officer of DSC. You may not remove any proprietary notices, marks or l abels from the S oftware P roduct. You shall i nsti­tute reasonable meas ures to ensure compliance with the te rms and conditions of this EULA.
(b) Separation of Components - The S oftware P roduct is licensed as a single product. Its component parts may not be separated for use on more than one H ARDWARE unit.
(c) S ingle INTEGRATED P RODUCT - If You acquired this S OFTWARE with HARDWARE, then the SOF TWARE PRODUCT is licensed wi th t he HARDWARE as a single integrated product. In this case, the SOF TWARE P RODUCT may only be used wit h the H ARDWARE as set forth in this EULA.
(d) Rental - You may not rent, lease or lend the SOF TWARE PRODU CT. You may not make it available to others or post it on a server or web site.
(e) S oftware P roduct Transfer - Y ou may transfer al l of Your rights under this EU LA only as part of a permanent s ale or transfer of the HA RDWARE, provided You retain no copies, Y ou transfer all of the SO FTWARE P RODUCT (including all component parts, the media and printed material s, any upgrades and this EULA ), and provided the recipient agrees to the terms of this EULA. If the SOFTWARE PRODUCT is an upgrade, any transfer must als o include all prior versions of the S OFTWARE PRODUCT.
(f) Termination - Without prejudice to any other rights, DSC may terminate this EU LA if You fail to comply wit h t he t erms and conditions of this EULA. In such event, You must des troy all copies of the S OFTWARE P RODUCT a nd all of its component parts.
(g) Trademarks - This EULA does not grant You any rights in connection with any trademarks or service marks of DSC or i ts s uppliers.
3. COPYRIGHT
All ti tle and intellectual property rights in and to the S OFTWARE P RODUCT (including but not limited to any i mages, photographs, and text incorporated into t he SOFTWARE PRODUCT), the accompanying printed materials, and any copies of t he S OFTWARE PRODUCT, are owned by DS C or its suppliers. You may not copy the printed materials accompanying the SOF TWARE PRODU CT. All ti tle and intellectual property rights in and to the content which may be acces sed throughuse of the SOFTWARE PRODUCT are the property of the respective content owner and may be protected by applicable copyright or other i ntellectual property laws and treatie s. This EULA grants You no rights to use such content. A ll rights not expressly granted under this EULA are reserved by DSC and its suppliers.
4. EXPORT RESTRICTIONS
You agree that You will not export or re-export the SOFTWARE PRODUCT to any country, person, or entity subject to Canadian export rest rictions.
5. CHOICE OF LAW
This Software License Agreement is governed by the laws of the P rovince of O ntario, Canada.
6. ARBITRATION
All disputes arising in connectionw ith this A greement shall be determined by final and binding arbitration i n ac cordance with the Arbitration Act, and the parties agree to be bound by the arbitrator’s decision. The place of arbitration shall be Toronto, Canada, and the l anguage of the arbitration s hall be English.
7. LIMITED WARRANTY
(a) NO WARRANTY - D SC PROVIDES THE SOFTWARE “AS IS” WITHOUT WARRANTY. DSC DO ES NOT WARRANT THAT THE SOF TWARE WILL MEET YOUR REQUIREMENTS OR TH AT OPERATION OF THE S OFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE.
(b) CHANGES IN OPERATING ENVIRONMENT - D SC shall not be responsible for problems caused by changes i n the operating characterist ics of the HARDWARE, or for problems in the interaction of the SO FTWARE P RODUCT with non-DSC-SOFTWARE or HARDWARE PRODUCTS.
(c) LIMITATION OF LIABILITY - WARRANTY REFLECTS ALLOCATION O F RISK - IN AN Y EVENT, IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE A GREEMENT, DSC’S ENTIRE LIABILITY UND ER AN Y PROVISION OF THIS LICENSE A GREEMENT
SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY Y OU TO LICENSE THE S OFTWARE PRODUCT AND FIVE
29010318R003
CANADIAN DO LLARS (CAD$5.00). BECAUSE S OME J URISDICTIONS DO NO T ALLOW THE EXCLUSION O R LIMITATION OF LIABILITY FO R CONSEQUENTIAL OR INCIDENTAL DAMA GES, THE ABOVE LIMITATION MAY NOT AP PLY TO YOU.
(d) DISCLAIMER OF WARRANTIES - THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND A LL OTHER WARRANTIES, WHETHER EXPRESS ED OR IMPLIED (INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY O R F ITNESS FOR A PARTICULAR PURPOS E) A ND OF ALL OTHER OBLIGATIONS O R LIABILITIES ON THE PART OF DSC. DS C M AKES N O OTHER WARRANTIES. DSC NEITHER AS SUMES NOR AUTHORIZES ANY OTHER PERSON P URPORTING TO ACT ON ITS BEHALF TO MOD IFY OR TO CHANG E THIS WARRANTY, NOR TO AS SUME F OR IT A NY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT.
(e) EXCLUSIVE REMEDY A ND LIMITATION OF WARRANTY - U NDER NO CIRCUMSTANCES S HALL DS C BE LIABLE F OR ANY S PECIAL, INCIDENTAL, CONSEQUENTIAL O R INDIRECT DA MAGES BASED UPO N BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE, S TRICT LIABILITY, OR ANY OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE, BUT A RE NO T LIMITED TO , LOS S OF PROFITS, LOSS OF THE SOFTWARE PRODUCT OR ANY ASSO CIATED EQU IPMENT, COST OF CAPITAL, COST OF S UBSTITUTE OR REPLACEMENT EQU IPMENT, FACILITIES OR SERVICES, DOWN TIME, PURCHASERS TIME, THE CLAIMS O F THIRD PARTIES, INCLUDING CUSTOMERS, AN D INJU RY TO PROPERTY.
WARNING: DSC recommends that the entire s ystem be completely t ested on a regular basis . However, despite frequent test ing, a nd due t o, but not limite d to, criminal tampering or elect rical disruption, i t is possible for t his SOFTWARE P RODUCT to fail to perform as expected. FCC Compliance Stat ement­CAUTION:Changes or modifications not expressly approved by DSC could void your authority to use t his equipment.
This equipment generates and us es radio frequency energy and if not ins talled and used properly, in s trict accordance wi th the manufacturer’s i nstructions, may cause inter­ference to radio and televis ion reception. It has been type tested and found to comply w ith the limits for Class B device in accordance w ith the specificati ons i n S ubpart “B” of Part 15 of F CC Rules, which are designed to provide reas onable protection against s uch i nterference in any residential installation. However, there is no guarantee that interference wil l not occur in a particular installa tion. If this equipment does cause i nterference to televisi on or radio reception, which can be determined by turning the equipment off and on, the user is encouragedt o t ry to correct the interference by one or more of the following measures:
- Re-orient t he receiving antenna
- Relocate the al arm control with respect to the receiver
- M ove the alarm control aw ay from t he receiver
- Connect the al arm control into a different outlet so that al arm control and receiver are on different ci rcuits.
If necess ary, the user should consult the dealer or an experiencedradio/televis ion technician for additional suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/ Televis ion Interference Problems”. This booklet is available from the U. S. Government Printing Office, Wash­ington, D. C. 20402, Stock # 004-000-00345-4.
This Class Bdigital apparatus complies with CAN ICES-3(b)/nmb-3(b).
EN50131-1Grade2/Class II
The Model HS 2TCHPRO/HS2TCHPROBLK Keypad has been certified by Tel efication according to EN50131-1:2006 + A1:2009 + A2:2017, EN50131-3:2009 for Grade 3, Class II.
Note: For EN50131 compliant instal lations the following functions (initi ated from the keypad emergencybuttons) have to be disabled:
- F ire Alarm function
- A uxiliary (Medical) Alarm function
- P anic Alarm function
© 2018 Tyco Security Products. All Rights Reserved Toronto, Canada • www.dsc.com
The trademarks, logos, and service marks displayed on this document are registered in the United States [or other count ries]. Any misuse of the trademarks is strictly prohibited and Tyco will aggressively enforce its intellectual property rights to the fullest extent of the law, including pursuit of criminal prosecution wherever necessary. All trademarks not owned by Tyco are the property of their respective owners, and are used with permission or allowed under applicable laws. Product offerings and specifications are subject to change without notice.
Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales represent ative.
Pour télécharger le mode d’emploi en intégralité et enregistrer votre produit, ren­dez-vous sur: www.dsc.com/m/29010319 ou scannez le code QR à droit e.
Mode d’emploi de l’écran tactile
HS2TCHPRO/HS2TCHPROBLK
AVERTISSEMENT: le présent manuel contient des informations au sujet des li mites d’utilisation et de fonc­tionnement du produit, ainsi que des informations sur les limites de responsabilité du fabricant . Lisez atten­tivement le manuel dans son i ntégralité.
MISE EN GARDE: Ce manuel contient des informations sur les limitations concernant l’utilisation et le fonc­tionnement du produit ainsi que des informations sur les limitations et les obligations du fabricant Lisez atten­tivement le guide complet.

Avis de sécurité

Avis de sécurité
Ce manuel doit être utilisé conjointement avec le Mode d’emploi de la centrale d’alarme PowerSeries Pro compatible : HS3032, HS3128, HS3248.
Assurez-vous toujours d’être en possession de la dernière version du mode d’emploi. Des versions plus récentes de ce manuel sont disponibles sur demande auprès de votre distributeur.
Avertissement: Lisez et conservez ces instructions! Respectez tous les avertissements et instructions donnés dans ce document et/ou sur l’équipement.

Consignes de sécurité importantes

Afin de limiter les risques d’incendie, de décharge électrique ou de blessures, observez les point s suivants :
l Ne déversez aucun type de liquide sur l’équipement. l Ne tentez pas de réparer cet appareil vous-même. L'ouverture ou le retrait des panneaux peut vous expo-
ser à des tensions dangereuses ou à d'autres risques. Confiez toute réparation à un réparateur qualifié. N’ouvrez en aucun cas l’appareil vous-même.
l Évitez de toucher l’équipement et les câbles qui lui sont connectés lors d’orages; des risques d’élec-
trocution sont possibles.
l N’utilisez pas le système d’alarme pour signaler une fuite de gaz, si le système se t rouve près d’une
fuite.

Maintenance habituelle et dépannage

Gardez le clavier de l’écran tactile HS2TCHPRO/HS2TCHPROBLK dans un état optimal en suivant toutes les ins­tructions incluses dans ce manuel et/ou marquées sur le produit.

Précautions de manipulation

N’appliquez pas de force excessive sur la surface de l’écran ou les parti es adjacentes, car cela pourrait altérer le ton des couleurs.

Nettoyage

l Si la surface de l ’écran est cont aminée, soufflez sur la surface et essuyez-la délicatement avec un chiffon
propre et sec. Si l’écran n’est touj ours pas complètement propre, humidifiez le chiffon avec de l’alcool isopropylique.
l N’utilisez pas de nettoyants abrasifs, d’eau, de diluants ou d’aérosols (poli), aucun solvant aromatique,
cétone, etc. qui pourraient pénétrer par les trous du clavier de l’écran tactile HS2TCHPRO/HS2TCHPROBLK et causer des dommages.

Dépannage

De temps en temps, votre système peut rencontrer un problème. Dans ce cas, votre centrale d’alarme affichera un message d’erreur. Lorsqu’un message d’erreur apparaît sur l’écran, consultez la liste des messages d’erreur fournie pour en savoir plus. Si vous avez besoin d’aide, contactez votre distributeur pour une assistance technique.
Avertissement: Cet équipement, l e clavier à écran tactile HS2TCHPRO/HS2TCHPROBLK, doit être installé et uti­lisé dans un environnement non dangereux de pollution de type 2 maximum, et de surtension de catégorie II, uni­quement en intérieur. Il est conçu pour être installé, entretenu et/ou réparé uniquement par des techniciens [une personne ayant la formation technique appropriée et l’expérience nécessaire pour connaître les dangers auxquels elle peut s’exposer en effectuant une tâche et les mesures pour réduire les risques pour elle-même et les autres per­sonnes]. Cet équipement ne contient aucune pièce remplaçable par l’utilisateur final.
Avertissement: N’obstruez jamais l’accès à la centrale d’alarme à laquelle cet équipement est connecté. Ces pré­cautions de sécurité ne vous dispensent pas de contacter le distributeur et/ou le fabricant afin d’obtenir des cla­rifications supplémentaires et/ou des réponses à vos préoccupations.
- 2 -

Démarrage rapide

Description : Arme tous les détecteurs intérieurs et extérieurs
Armement en mode absence
Armement en mode à domicile
Désarmement
Suspension
Visualiser les alarmes
Visualiser les pro­blèmes
Exécuter un test du système
Régler l’heure/la date
Activer/Désactiver le carillon
Régler la lumi­nosité de l’écran
Méthode: Appuyez sur le bandeau supérieur de la page d’accueil
Indications :
Description : Arme tous les détecteurs extérieurs. N’arme pas les détecteurs intérieurs Méthode: Appuyez sur la touche Armement en mode à domicile
Indications :
Description : Désactive tous les détecteurs int érieurs et extérieurs Méthode: Appuyez sur le bandeau supérieur de la page d’accueil
Indications :
Description :
Méthode:
Indications : la touche Suspension change et devient Annulation de suspension
Description : Afficher quelles zones ont déclenché des alarmes Méthode: Appuyez sur la touche! (visible si une alarme est survenue) Indications : la touche ! s’affiche en haut à droite de l’écran Description : Visualiser les problèmes du système Méthode: Appuyez sur la touche! (visible si une alarme est survenue) Indications : la touche ! s’affiche en haut à droite de l’écran
Description :
Méthode: Options + Fonctions utilisateur + [Code d’accès] + Test du système
Indications :
Description : Règle l’heure et la date affichées sur la page d’accueil
Méthode:
Indications : Les modifications sont affichées en haut à droite de la page d’accueil Description : Active/désactive le carillon de porte Méthode: Appuyez sur Carillon
Indications :
Description : Règle la luminosité et le contraste de l’écran tactile
Méthode:
Indications : La luminosité de l’écran change avec la position du curseur
Démarrage rapi de
Armement
Le voyant Armé ( ) s’allume. Le bandeau supérieur devient rouge et indique «Armé». Démarrage de la temporisation de sortie.
Le voyant Armé ( ) s’allume. Le bandeau supérieur devient rouge et indique «Armé»
Le voyant Prêt ( ) s’allume. Le bandeau supérieur devient vert et indique «Désarmé»
Exclut les zones sélectionnées de manière à ce qu’elles ne puissent pas acti­ver l’alarme lorsque le système est armé
Appuyez sur Suspension de zone pour afficher les zones disponibles, pui s appuyez sur la touche Suspension à côté d’une zone
Fonctions communes
Teste l’avertisseur du clavier, la sirène, les voyants d’état et la batterie de secours
L’avertisseur et la sirène sont activés pendant 2 secondes, tous les voyants s’allument, les voyants Prêt, Armé et Problème clignotent pendant toute la durée du test
Options + Fonctions utilisateur + [code d’accès] + Heure et date. Appuyez sur la section que vous souhait ez modifier (par ex., Hrs) puis utilisez les flèches pour changer la valeur. Appuyez sur Enregistrer
Activé: l’avertisseur émet 3 bips courts. L’icône de carillon affiche une coche. Désactivé: l’avertisseur émet 1 bip long. L’icône de carillon affiche un X.
Options + Fonctions utilisateur + [Code d’accès] + Config. clavier + Options d’affichage
Utilisez les curseurs pour augmenter ou diminuer la luminosité de l’écran
- 3 -
Démarrage rapi de
Régler le volume de l’avertisseur
Description : Règle le niveau sonore de l’avertisseur du clavier
Options + Fonctions utilisateur + [Code d’accès] + Config. clavier + Com-
Méthode:
Indications : L’avertisseur retentit au niveau de volume sélectionné
mande de l’avertisseur
Utilisez le curseur pour augmenter ou diminuer l e volume de l’avertisseur
- 4 -
Loading...
+ 33 hidden pages