EP/VP Series
Tapped insert:
D
E
No. 6-32 x 1/4 (2)-EP7
No. M-3 x .5 (2)-EP7M
C
B
.235
5.96
1.575
40.01
.157
3.98
.910
23.11
Dia. (2)
1.295
32.89
R
UL Recognized
CSA Certified
VDE Approved
CORCOM Product Guide
RFI Power Line Filters for Switching Power Supply Noise Suppression
EP1/VP1
EP3/VP3
EP3/VP3
P7/VP7
E
EP/VP Series
The EP/VP series of RFI filters has been developed to
reduce conducted noise to acceptable limits for
equipment that must comply with the requirements
of CISPR in Europe and the FCC specifications in the USA.
These filters provide high insertion loss for both lineto-ground and line-to-line emissions throughout the
frequency range. They are particularly well suited
for equipment to better meet both stringent emissions
specifications (such as CISPR 22, A-level and FCC
Part 15J, Class B) and the EP models meet very low
leakage current requirements.
Tyco Electronics Corcom Products has extended the EP
Series of Power Line Filters by adding a 7 Amp and 12
Amp versions to the existing 3, 6, 10, and 20 Amp product
offering. The new filters offer higher performance in a
smaller package at a lower price than the existing 6 Amp
and 10 Amp versions. The smaller package size and
comparable performance is a better match to Schaffner's
FN 2070 Series. The new filters are RoHS compliant.
Electrical Schematic
Resistor location for reference only.
Recommended Panel Cutout
Panel Cutout (back mount)
.005 [
±
Tolerance
0.13]
Specifications
Maximum leakage current,each line-to-ground
Models EP Models
VP
@ 120 VAC 60 Hz: .73mA .21mA
@ 250 VAC 50 Hz: 1.27mA .36mA
Hipot rating (one minute):
line-to-ground 2250 VDC
line-to-line 1450 VDC
Operating frequency: 50/60 Hz
Rated voltage (max.): 250 VAC
Rated current:
03EP 3A 10EP 10A
06EP 6A 12EP 12A
7EP 7A 20EP/VP 20A
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current Frequency–MHz
Rating .01 .05 .15 .5 1 5 10 30
EP
3A 1 10 58 65 65 66 60 25
6A,10A 1
7A 15 28 63 75 78 75 75 55
12A 12
20A 3 6 28 50 55 60 55 55
VP
20A 3 2 42 60 65 65 55 55
Line-to-line in 50 ohm circuit
Current Frequency–MHz
Rating .01
EP1, EP3
3A 1
6A,10A 1 30 65 65 65 65 35 35
7A 10 43 55 65 68 70 65 50
12A 11 7 13 70 70 70 65 45
20A
VP
20A
10 58 65 65 66 60 25
68 70 70 70 45
52
7
.15 .5 1 5 10 20 30
65 65 65 65 58 58
36
8 25 60 65 65 58 58 58
25 60 65 65 58 58 58
8
56
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 04-06 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics
are metric equivalents. to change.
Specifications subject
Germany: 49-89-6089-0
CORCOM Product Guide
A
D
E
C
B
Brown
Blue
Brown
Blue
Green/
Yellow
A
Tapped insert:
D
E
No. 6-32 x 1/4 (2)-EP7
No. M-3 x .5 (2)-EP7M
C
B
RFI Power Line Filters for Switching Power Supply Noise Suppression (Continued)
EP/VP Series
Case Styles
EP1/VP1 (1-15 Amp version)
20EP1/VP1
Typical dimensions:
Terminals: .250 [
Mounting Holes: .188 [
EP3
Typical dimensions:
Wire leads: 4.0 [
EP7 & EP7M
6.35] (5) Holes: .07 [1.8] Dia.(4)
4.78] Dia. (2) Slot: .07 x .16 [1.8 x 4.1]
101.6] Min. Mounting Holes: .188 [4.78]Dia.(2)
(with metric insert)
20EP/VP6
erminals: No. 8-32 (5) T
T
orque: 18 ± 2 in.lb
Case Dimensions
Part No. (max) (max) (max)
3EP1
3EP3
3EP7
3EP7M
6EP1
6EP3
7EP1
7EP3
10EP1
10EP3
12EP1
12EP3
20EP1, 20VP1
20EP6, 20VP6
ABCDE
3.85 2.07 1.78 2.938 3.35
97.8 52.6 45.2 74.63 85.1
2.56 2.07 1.78 2.938 3.35
65.0 52.6 45.2 74.63 85.1
3.21 2.25 1.78 1.575 0.63
81.5 57.2 45.2 40.01 12.1
3.21 2.25 1.78 1.575 0.63
81.5 57.2 45.2 40.01 12.1
6.62 2.07 2.28 5.625 6.03
168.1 52.6 57.9 142.88 153.2
5.33 2.07 2.28 5.625 6.03
135.4 52.6 57.9 142.88 153.2
4.79 2.07 1.53 3.947 4.33
121.7 52.6 38.9 100.25 109.98
3.50 2.07 1.53 3.947 4.33
88.9
52.6 38.6 100.25 109.98
6.62 2.07 2.78 5.625 6.03
168.1 52.6 70.6 142.88 153.2
5.35 2.07
2.78 5.625 6.03
135.9 52.6 70.6 142.88 153.2
4.97 2.25 1.78 4.063 4.46
126.2 57.2 45.2 103.20 113.28
3.624 2.25 1.78 4.063 4.46
92.05 57.15 45.2 103.20 113.28
4.95 2.27 1.8 4.063 4.47
125.7 57.7 45.7 103.2 113.5
5.09 2.25 1.78 4.063 4.46
127.3
57.2 45.2
± .015 (max)
±.38
103.2 129.3
†
±.02 [±.5]
RFI Power Line Filters
†
†
Part Numbers
3EP1 6EP1
10EP1
3EP3 6EP3 10EP3 20EP6
Typical dimensions:
Terminals: .250 [
Slot: .07 x .16 [
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 04-06 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
6.35] (3) Holes: .07 [1.8] Dia.(2)
1.8 x 4.1]
specified. Values in italics
are metric equivalents. to change.
Specifications subject
3EP7M 7EP3 12EP3 20VP6
Line Cord No. GA400
1/2
7
foot, 3-conductor line cord.
Germany: 49-89-6089-0
3EP7
7EP1
12EP1
20EP1
20VP1
57