TYAN GT24B-B7076 Service Engineer's Manual

GT24B-B7076
Service Engineer’s Manual
2
http://www.tyan.com
PREFACE
Copyright
This publication, including all photographs, illustrations, and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of manufacturer.
Copyright 2015 MiTAC International Corporation. All rights reserved. TYAN® is a registered trademark of MiTAC International Corporation.
Version 1.0
Disclaimer
Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and reliability prior to printing. MiTAC assumes no liability whatsoever, and disclaims any express or implied
warranty, relating to sale and/or use of TYAN® products including liability or warranties relating to fitness for a particular purpose or merchantability. MiTAC retains the right to make changes to produce descriptions and/or specifications at any time, without notice. In no event will MiTAC be held liable for any direct or indirect, incidental or consequential damage, loss of use, loss of data or other malady resulting from errors or inaccuracies of information contained in this document.
Trademark Recognition
All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including, but not limited to the following.
TYAN® is a trademark of MiTAC International Corporation. Intel® is a trademark of Intel® Corporation. AMD® is a trademark of AMD® Corporation. AMI®, AMIBIOS® and combinations thereof are trademarks of AMI Technologies. Microsoft®, Windows® are trademarks of Microsoft Corporation. IBM®, PC®, AT® and PS/2® are trademarks of IBM Corporation. Winbond® is a trademark of Winbond Electronics Corporation.
3
http://www.tyan.com
FCC Declaration
Notice for the USA
Compliance Information Statement (Declaration of Conformity Procedure) DoC FCC Part 15: This device complies with part 15 of the FCC Rules
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
This device must not cause harmful interference.  This device must accept any interference received, including
interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Notice for Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.
Notice for Europe (CE Mark)
This product is in conformity with the Council Directive 2004/108/EC.
CAUTION: Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. There will be danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer. Dispose of used battery according to manufacturer instructions and in accordance with your local regulations.
4
http://www.tyan.com
About this Manual
This manual provides you with instructions on installing your TYAN GT24B-B7076.This manual is intended for trained service technician/ personnel with hardware knowledge of computers..
This manual consists of the following parts:
1. Chapter1: Product Introduction
Provides an introduction to the TYAN GT24B-B7076 barebones, standard parts list, describes the external components, gives a table of key components, and provides block diagram of the system.
2. Chapter2: Hardware Setup
Covers procedures on installing the CPU, memory modules and hard drives.
3. Chapter3: Installation Options
Covers removal and replacement procedures for pre-installed components.
4. Appendix:
List the cable connection and FRU part tables for reference of system setup, and technical support in case a problem arises with your system.
5
http://www.tyan.com
Safety and Compliance Information
Before installing and using TYAN GT24B-B7076, take note of the following precautions:
·Read all instructions carefully.
·Do not place the unit on an unstable surface, cart, or stand.
·Do not block the slots and opening on the unit, which are provided for
ventilation.
· Only use the power source indicated on the marking label. If you are not
sure, contact the power company.
·The unit uses a three-wire ground cable, which is equipped with a third pin to
ground the unit and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not support this kind of plug, contact your electrician to replace your obsolete outlet.
·Do not place anything on the power cord. Place the power cord where it will
not be in the way of foot traffic.
·Follow all warnings and cautions in this manual and on the unit case.
·Do not push objects in the ventilation slots as they may touch high voltage
components and result in shock and damage to the components.
· When replacing parts, ensure that you use parts specified by the
manufacturer.
·When service or repairs have been done, perform routine safety checks
to verify that the system is operating correctly.
·Avoid using the system near water, in direct sunlight, or near a heating
device.
·Cover the unit when not in use.
6
http://www.tyan.com
Safety Information
Retain and follow all product safety and operating instructions provided with your equipment. In the event of a conflict between the instructions in this guide and the instructions in equipment documentation, follow the guidelines in the equipment documentation.
Observe all warnings on the product and in the operating instructions. To reduce the risk of bodily injury, electric shock, fire and damage to the equipment, observe all precautions included in this guide.
You must become familiar with the safety information in this guide before you install, operate, or service TYAN products.
Symbols on Equipment
Caution. This symbol indicates a potential hazard.
The potential for injury exists if cautions are not observed. Consult equipment documentation for specific details.
Warning. This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
Warning. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. To reduce risk of injury from a hot component, allow the surface to cool before touching.
Warning. This symbol indicates hazardous moving parts. Keep away from moving fan blades.
Caution. Slide-mounted equipment is not to be used as a shelf or a work space.
7
http://www.tyan.com
General Precautions
· Follow all caution and warning instructions marked on the equipment and explained in the accompanying equipment documentation.
Machine Room Environment
 · Make sure that the area in which you install the system is properly
ventilated and climate-controlled.
· Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the electrical rating label of the equipment.
· Do not install the system in or near a plenum, air duct, radiator, or heat register.
· Never use the product in a wet location.
Equipment Chassis
· Do not block or cover the openings to the system.
· Never push objects of any kind through openings in the equipment.
Dangerous voltages might be present.
· Conductive foreign objects can produce a short circuit and cause fire, electric shock, or damage to your equipment.
· Lift equipment using both hands and with your knees bent.
Equipment Racks
To avoid injury or damage to the equipment:
· Observe local occupational health and safety requirements and guidelines for manual materials handling.
· Do not attempt to move a rack by yourself; a minimum of two people are needed to move a rack.
· Do not attempt to move a fully loaded rack. Remove equipment from the rack before moving it.
· Do not attempt to move a rack on an incline that is greater than 10 degrees from the horizontal.
8
http://www.tyan.com
· Make sure the rack is properly secured to the floor or ceiling.
· Make sure the stabilizing feet are attached to the rack if it is a single-rack
installation.
· Make sure racks are coupled together if it is a multiple-rack installation.
· Make sure the rack is level and stable before installing an appliance in the
rack.
· Make sure the leveling jacks are extended to the floor.
· Make sure the full weight of the rack rests on the leveling jacks.
· Always load the rack from the bottom up. Load the heaviest component in
the rack first.
· Make sure the rack is level and stable before pulling a component out of the rack.
· Make sure only one component is extended at a time. A rack might become unstable if more than one component is extended.
To avoid damage to the equipment:
· The rack width and depth must allow for proper serviceability and cable management.
· Ensure that there is adequate airflow in the rack. Improper installation or restricted airflow can damage the equipment.
· The rack cannot have solid or restricted airflow doors. You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system.
· If you install the Model in a rack, do not place equipment on top of the unit. It will cause restricted airflow and might cause damage to the equipment.
· Make sure the product is properly matted with the rails. Products that are
improperly matted with the rails might be unstable.
· Verify that the AC power supply branch circuit that provides power to the
rack is not overloaded. This will reduce the risk of personal injury, fire, or damage to the equipment. The total rack load should not exceed 80 percent of the branch circuit rating. Consult the electrical authority having jurisdiction over your facility wiring and installation requirements.
9
http://www.tyan.com
Equipment Power Cords
· Use only the power cords and power supply units provided with your system. The system might have one or more power cords.
· Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
· In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do not ground the Green/Yellow tab, it can
cause an electrical shock due to high leakage currents.
· Do not place objects on AC power cords or cables. Arrange them so that no
one might accidentally step on or trip over them.
· Do not pull on a cord or cable. When unplugging from the electrical outlet,
grasp the cord by the plug.
· To reduce the risk of electrical shock, disconnect all power cords before
servicing the appliance.
Equipment Batteries
· The system battery contains lithium manganese dioxide. If the battery pack is not handled properly, there is risk of fire and burns.
· Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or water.
· Do not expose the battery to temperatures higher than 60°C (140°F).
· The system battery is not replaceable. If the battery is replaced by an
incorrect type, there is danger of explosion. Replace the battery only with a spare designated for your product.
· Do not attempt to recharge the battery.
· Dispose of used batteries according to the instructions of the manufacturer.
Do not dispose of batteries with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to TYAN, your authorized TYAN partner, or their agents.
Equipment Modifications
· Do not make mechanical modifications to the system. TYAN is not responsible for the regulatory compliance of TYAN equipment that has been
modified.
10
http://www.tyan.com
Equipment Repairs and Servicing
· The installation of internal options and routine maintenance and service of this product should be performed by trained service technicians/personnel
who are knowledgeable about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels.
· Do not exceed the level of repair specified in the procedures in the product documentation. Improper repairs can create a safety hazard.
· Allow the product to cool before removing covers and touching internal components.
· Remove all watches, rings, or loose jewelry when working before removing covers and touching internal components.
· Do not use conductive tools that could bridge live parts.
· Use gloves when you remove or replace system components; they can
become hot to the touch.
· If the product sustains damage requiring service, disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider. Examples of damage requiring service include:
The power cord, extension cord, or plug has been damaged. Liquid has been spilled on the product or an object has fallen into the
product.
The product has been exposed to rain or water. The product has been dropped or damaged. The product does not operate normally when you follow the operating
instructions.
11
http://www.tyan.com
Table of Contents
Chapter 1: Overview ........................................................................ 13
1.1 About the TYAN GT24B-B7076 ............................................. 13
1.2 Product Model ........................................................................ 13
1.3 Features ................................................................................. 14
1.4 Standard Parts List ................................................................. 19
1.4.1 Box Contents ................................................................... 19
1.6 About the Product ................................................................... 20
1.6.1 System Front View .......................................................... 20
1.6.2 System Rear View ........................................................... 21
1.6.3 LED Definitions ................................................................ 22
1.6.4 Motherboard (S7076) Layout .......................................... 24
1.6.5 Jumpers & Connectors .................................................... 25
1.6.6 System Block Diagram ..................................................... 27
1.6.7 Internal View .................................................................... 28
Chapter 2: Setting Up ...................................................................... 30
2.0.1 Before you Begin ............................................................. 30
2.0.2 Work Area ........................................................................ 30
2.0.3 Tools ................................................................................ 30
2.0.4 Precautions ...................................................................... 31
2.1 Installing Motherboard Components ...................................... 32
2.1.1 Removing the Chassis Cover .......................................... 32
2.1.2 Installing the CPU and Heatsink ...................................... 33
2.1.3 Installing the PCI-E Cards ............................................... 36
2.1.4 Installing the Memory ...................................................... 40
2.1.5 Installing Hard Drives ...................................................... 44
2.2 Rack Mounting ........................................................................ 49
2.2.1 Installing the Server in a Rack ......................................... 49
Chapter 3: Replacing Pre-Installed Components ......................... 55
3.1 Introduction ............................................................................. 55
3.2 Disassembly Flowchart ........................................................... 55
3.3 Removing the Cover ............................................................... 56
3.4 Replacing Motherboard Components ..................................... 56
3.4.1 Replacing Expansion Card .............................................. 56
3.4.2 PCI-E Riser Cards Specification ..................................... 57
3.4.3 Disconnecting All Motherboard Cables ........................... 58
3.4.4 Removing the Motherboard ............................................. 59
3.6 Replacing the LED Control Board ........................................ 60
3.6.1 M1008-G2024 LED Control Board Features ................... 62
12
http://www.tyan.com
3.6.2 M1008-G2024 LCB Connector Pin Definition.................. 62
3.7 Replacing the System Fan.................................................... 64
3.8 Installing the System Fan ..................................................... 65
3.9 Replacing the HDD Backplane Board .................................. 66
3.9.1 M1277 HDD Backplane Board Features ............................. 68
3.9.2 Pin Definition ....................................................................... 69
3.10 Replacing the Power Supply ................................................ 70
3.10.1 Replacing the M7016-B7066 Power Distribution Board 73
3.10.2 M7016-B7066 Power Distribution Board Feature ......... 75
3.10.3 M7016-B7066 Power Distribution Board Pin Definitions 75
3.11 Replacing the Redundant Power Supply .............................. 77
Appendix I: Fan and Temp Sensors ............................................... 79
Appendix II: Cable Connection Tables .......................................... 83
Appendix III: FRU Parts Table ......................................................... 85
Appendix IV: Technical Support ..................................................... 86
http://www.tyan.com
13
Chapter 1: Overview
1.1 About the TYAN GT24B-B7076
Congratulations on your purchase of the TYAN® GT24B-B7076, a highly optimized rack-mountable barebone system. The GT24B-B7076 is designed to support dual Intel
®
Xeon E5-2600v3 series processors, and up to 2048GB LRDIMM 3DS/ 1024GB
LRDIMM/512GB RDIMM DDR4 memory. Leveraging advanced technology from Intel®,
GT24B-B7076 server system is capable of offering scalable 32 and 64-bit computing, high bandwidth memory design, providing a rich feature set and incredible performance. and lightning-fast PCI-E bus implementation. The GT24B-B7076 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage.
TYAN® also offers the GT24B-B7076 in a version that can support up to to four hot-swap hard drives. The GT24B-B7076 uses TYAN®’s latest chassis, featuring a robust structure and a solid mechanical enclosure. All of this provides GT24B –B7076 the power and flexibility to meet the needs of nowadays server application.
1.2 Product Model
Model
Config
HDD Bays
Power supply
GT24B-B7076
B7076G24BV4HR
Hot-swap, 4
HDDs
3Y YM2451G
(1+1) Redundant
PSU
B7076G24BV4H
Hot-swap, 4
HDDs
Delta DPS-500AB-
5 C*1 Single PSU
14
http://www.tyan.com
1.3 Features
TYAN GT24B7076 (B7076G24BV4HR)
System
Form Factor
1U Rackmount
Gross Weight
16 kg
Chassis Model
GT24B
Dimension (D x W x H)
25.4" x 17.2" x 1.72" (645 x 436 x 43.6mm)
Motherboard
S7076GM2NR
Board Dimension
EATX, 12"x13" (305x330mm)
Front Panel
Buttons
(1) PWR / (1) RST / (1) NMI / (1) ID
LEDs
(1) PWR / (1) HDD / (1) ID / (1) Warning / (3) LAN
I/O Ports
(2) 2.0 USB ports
External Drive Bay
Type / Q'ty
2.5"/3.5" Hot-Swap / (4)
HDD backplane support
SATA 6.0Gb/s;
System Cooling Configuration
FAN
(6) 4cm fans
Power Supply
Type
RPSU
Efficiency
PFC / 80 plus gold
Redundancy
1+1
Input Range
100-240V~ /8-4A
Frequency
50 - 60 Hz
Output Watts
450 Watts
Processor
Supported CPU Series
Intel Xeon Processor E5-2600 v3 series processors
Socket Type / Q'ty
LGA2011 / (2)
Thermal Design Power (TDP) wattage
Max up to 135W
System Bus
Up to 9.6/ 8.0/ 6.4 GT/s with Intel QuickPath Interconnect (QPI) support
Chipset
PCH
Intel C612
Memory
Supported DIMM Qty
(8)+(8) DIMM slots
DIMM Type / Speed
RDIMM DDR4 2133/1866/1600 / LRDIMM DDR4 2133/1600 / LRDIMM 3DS DDR4 2133/1600
Capacity
Up to 512GB RDIMM/ 1,024GB LRDIMM/ 2,048GB LRDIMM 3DS *Follow latest Intel DDR4 Memory POR
Memory channel
4 Channels per CPU
Memory voltage
1.2V
Expansion
PCI-E
(2) PCI-E Gen3 x16 slots (w/ x8 link) total maximum
15
http://www.tyan.com
Slots
20W load
Note:
(1) OCP slot for OCP Mezz card
Recommended TYAN OCP Card
M7062-B811-1T, PCI-E Gen3 x8, Broadcom 10GbE Mezz Card / M7062-B810-2T, PCI-E Gen3 x8, Broadcom 10GbE Mezz Card / M7076-X540-2T, PCI-E Gen3 x8, Intel 10GbE Mezz Card / M7076-I350, PCI-E Gen3 x8, Intel (2)GbE Mezz Card / M7062-I599-1T, PCI-E Gen3 x8, Intel 10GbE Mezz Card / M7062-I599-2T, PCI-E Gen3 x8, Intel 10GbE Mezz Card
Pre-install TYAN Riser Card
M2091-R, PCI-E x16 1U riser card (right) / M2091, PCI-E x16 1U riser card (left) (*Need with tall bracket)
LAN
Port Q'ty
(2) GbE ports (1 port shared with IPMI)
Controller
Intel I350-AM2
Storage
SATA
Connector
(1) Mini-SAS (4-ports) + (2) SATA (totally support 6 ports)
Controller
Intel C612
Speed
6.0 Gb/s
RAID
RAID 0/1/10/5 (Intel RST)
SSATA
Connector
(1) Mini-SAS (4-ports)
Controller
Intel C612
Speed
6.0 Gb/s
RAID
RAID 0/1/10/5 (Intel RST) only for 4 SATA devices
Graphic
Connector type
D-Sub 15-pin
Resolution
Up to 1920x1200
Chipset
Aspeed AST2400
I/O Ports
USB
(2) USB3.0 ports (2 at rear)/ (3) USB2.0 ports (2 at front)+1 in the middle of MB
COM
(1) DB-9 COM port
VGA
(1) D-Sub 15-pin port
RJ-45
(2) GbE ports (1 port shared with IPMI)
System Monitoring
Chipset
Aspeed AST2400
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature
Monitors temperature for CPU & memory & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
Others
Watchdog timer support
Server Management
Onboard Chipset
Onboard Aspeed AST2400
AST2400 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / USB 2.0 virtual hub
AST2400 iKVM
24-bit high quality video compression / 10/100 Mb/s
16
http://www.tyan.com
Feature
MAC interface
BIOS
Brand / ROM size
AMI / 16MB
Feature
User-configurable H/W monitoring / SMBIOS
2.7/PnP/Wake on LAN / ACPI 3.0/ACPI sleeping states S1,S4,S5
Operating System
OS supported list
Please refer to our Intel OS supported list.
Regulation
FCC (DoC)
Class A
CE (DoC)
Yes
Operating Environment
Operating Temp.
10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6 Compliant
Yes
Package Contains
Barebone
(1) GT24B-B7076
Manual
(1) Quick Installation Guide
Installation CD
(1) TYAN installation CD
TYAN GT24B7076 (B7076G24BV4H)
System
Form Factor
1U Rackmount
Gross Weight
16 kg
Chassis Model
GT24B
Dimension (D x W x H)
25.4" x 17.2" x 1.72" (645 x 436 x 43.6mm)
Motherboard
S7076GM2NR
Board Dimension
EATX, 12"x13" (305x330mm)
Front Panel
Buttons
(1) PWR / (1) RST / (1) NMI / (1) ID
LEDs
(1) PWR / (1) HDD / (1) ID / (1) Warning / (3) LAN
I/O Ports
(2) 2.0 USB ports
External Drive Bay
Type / Q'ty
2.5"/3.5" Hot-Swap / (4)
HDD backplane support
SATA 6.0Gb/s; SAS 6.0Gb/s and SAS 12.0Gb/s with optional mezz card
System Cooling Configuration
FAN
(6) 4cm fans
Power Supply
Type
EPS1U
Efficiency
PFC / 80 plus Platinum
Input Range
100-127V AC/8A / 200-240V AC/4A
Frequency
50 /60 Hz
Output Watts
500 Watts
Processor
Supported CPU
Intel Xeon Processor E5-2600 v3 series processors
17
http://www.tyan.com
Series
Socket Type / Q'ty
LGA2011 / (2)
Thermal Design Power (TDP) wattage
Max up to 135W
System Bus
Up to 9.6/ 8.0/ 6.4 GT/s with Intel QuickPath Interconnect (QPI) support
Chipset
PCH
Intel C612
Memory
Supported DIMM Qty
(8)+(8) DIMM slots
DIMM Type / Speed
RDIMM DDR4 2133/1866/1600 / LRDIMM DDR4 2133/1600 / LRDIMM 3DS DDR4 2133/1600
Capacity
Up to 512GB RDIMM/ 1,024GB LRDIMM/ 2,048GB LRDIMM 3DS *Follow latest Intel DDR4 Memory POR
Memory channel
4 Channels per CPU
Memory voltage
1.2V
Expansion Slots
PCI-E
(2) PCI-E Gen3 x16 slots (w/ x8 link)
Note:
(1) OCP slot for OCP Mezz card/ (1) Proprietary slot for SAS Mezz card
Recommended TYAN OCP Card
M7062-B811-1T, PCI-E Gen3 x8, Broadcom 10GbE Mezz Card / M7062-B810-2T, PCI-E Gen3 x8, Broadcom 10GbE Mezz Card / M7076-X540-2T, PCI-E Gen3 x8, Intel 10GbE Mezz Card / M7076-3108-8I, PCI-E Gen3 x8, LSI SAS 12G Mezz Card / M7094-2308G-8I, PCI-E Gen3 x8, LSI SAS 6G Mezz Card / M7076-3008-8I, PCI-E Gen3 x8, LSI SAS 12G Mezz Card / M7076-I350, PCI-E Gen3 x8, Intel (2)GbE Mezz Card / M7062-I599-1T, PCI-E Gen3 x8, Intel 10GbE Mezz Card / M7062-I599-2T, PCI-E Gen3 x8, Intel 10GbE Mezz Card
Pre-install TYAN Riser Card
M2091-R, PCI-E x16 1U riser card (right) / M2091, PCI-E x16 1U riser card (left) (*Need with tall bracket)
LAN
Port Q'ty
(2) GbE ports (1 port shared with IPMI)
Controller
Intel I350-AM2
Storage
SATA
Connector
(1) Mini-SAS (4-ports) + (2) SATA (totally support 6 ports)
Controller
Intel C612
Speed
6.0 Gb/s
RAID
RAID 0/1/10/5 (Intel RST)
SSATA
Connector
(1) Mini-SAS (4-ports)
Controller
Intel C612
Speed
6.0 Gb/s
RAID
RAID 0/1/10/5 (Intel RST) only for 4 SATA devices
Graphic
Connector type
D-Sub 15-pin
18
http://www.tyan.com
Resolution
Up to 1920x1200
Chipset
Aspeed AST2400
I/O Ports
USB
(2) USB3.0 ports (2 at rear)/ (3) USB2.0 ports (2 at front)+1 in the middle of MB
COM
(1) DB-9 COM port
VGA
(1) D-Sub 15-pin port
RJ-45
(2) GbE ports (1 port shared with IPMI)
System Monitoring
Chipset
Aspeed AST2400
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature
Monitors temperature for CPU & memory & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
Others
Watchdog timer support
Server Management
Onboard Chipset
Onboard Aspeed AST2400
AST2400 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / USB 2.0 virtual hub
AST2400 iKVM Feature
24-bit high quality video compression / 10/100 Mb/s MAC interface
BIOS
Brand / ROM size
AMI / 16MB
Feature
User-configurable H/W monitoring / SMBIOS
2.7/PnP/Wake on LAN / ACPI 3.0/ACPI sleeping states S1,S4,S5
Operating System
OS supported list
Please refer to our Intel OS supported list.
Regulation
FCC (DoC)
Class A
CE (DoC)
Yes
Operating Environment
Operating Temp.
10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6 Compliant
Yes
Package Contains
Barebone
(1) GT24B-B7076
Manual
(1) Quick Installation Guide
Installation CD
(1) TYAN installation CD
19
http://www.tyan.com
1.4 Standard Parts List
This section describes GT24B-B7076 package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. The product should arrive packaged as illustrated below.
1.4.1 Box Contents
GT24B-B7076 Box Content
(1) 1U chassis  (1) S7076 pre-installed  (6) Fan modules  Power supply module for B7076G24BV4H: Flex ATX 500W, DELTA,
DPS-500AB-5 C, Platinum
(2) Power supply modules for B7076G24BV4HR: 450W, YM-2451G,3Y  (1) Hard Drive Backplane(M1277 G24-BP12-4 pre-installed)  (2) Riser Cards (M2091 & M2091R pre-installed)  (1) Front Panel Board (M1008-G2024-FPB pre-installed)  (1) Power Distribution Board for B7076G24BV4HR (M7016-B7066,R1.0
pre-installed)
GT24B-B7076 Accessories
(2) US Power Cord  (2) EU Power Cord  (1) Rack Mounting Kit  (1) Driver CD
(1) Quick Installation Guide (2) HDD Screws (2) Heatsink
http://www.tyan.com
20
1.6 About the Product
The following views show you the product.
1.6.1 System Front View
M1008-G2024 FPB
21
http://www.tyan.com
1.6.2 System Rear View
B7076G24BV4H
B7076G24BV4HR
http://www.tyan.com
22
1.6.3 LED Definitions
Front Panel
LED
State
LED Color
Behavior
NOTE
Power
Power On
Green
Solid On
Power Off
Green
Off
Warning
System normal
Amber
Off
BMC & HWM alert even
System alert
Amber
Solid On
HDD
HDD Ready
Green
Off
HDD Access
Green
Blinking
If one of HDD access then LED blinking
ID
ID located
Blue
Solid On
ID free
Blue
Off
LAN1
Access
Green
Blinking
Link
Green
Solid On
Off Link
Green
Off
LAN2
Access
Green
Blinking
Link
Green
Solid On
Off Link
Green
Off
LAN LED
10/100/1000 Mbps LAN Link/Activity LED Scheme
Left LED
Right LED
10 Mbps
Link
Green
Off
Active
Blinking Green
Off
100 Mbps
Link
Green
Solid Green
Active
Blinking Green
Solid Green
1000 Mbps
Link
Green
Solid Yellow
Active
Blinking Green
Solid Yellow
No Link
Off
Off
NOTE: “Left” and “Right” are viewed from the rear panel.
http://www.tyan.com
23
ID LED
LED
State
Color
Description
ID LED
On
Blue
System identified
Off
Off
System not identified
HDD LED
HDD Status
Status LED Color: Orange
Activity LED Color: Green
No Driver Present or power disconnected
OFF
OFF
Driver Present
No Activity
OFF
On Solid
Access Activity
OFF
Blinking
HDD Fail
On Solid
Dont care
Identify (Locate the HDD)
Blinking(1Hz)
Dont care
Rebuild
Blinking(4Hz)
Dont care
http://www.tyan.com
24
1.6.4 Motherboard (S7076) Layout
The diagram is representative of the latest board revision available at the time of publishing. The board you receive may not look exactly like the above diagram.
http://www.tyan.com
25
1.6.5 Jumpers & Connectors
Connector/Jumper
1 LAN2 + USB 3.0 x 2
22 PCH PWROK LED (LED2)
2 VGA / COM1
23 CAT Error LED (LED3)
3 ID LED Button (SW3)
24 ID LED Button Header (J56)
4 LAN1
25 Chassis Intrusion Header (J57)
5 COM2 Header (J68)
26 CPU0 FAN (J28)
6 SYS_FAN_4 (J31)
27 SSI 8-pin CPU0 Power Connector (PW1)
7 BMC LED (LED1)
28 SYS_FAN_3 (J35)
8 PSU Alert LED (LED10)
29 SYS_FAN_2 (J34)
9 Clear CMOS Button (SW4)
30 CPU0 PWOK LED (LED8)
10 Rear ID LED (LED7)
31 CPU0 Socket (U1)
11 SYS_FAN_5 (J32)
32 CPU1 PWOK LED (LED9)
12 7-pin Vertical SATA3.0 Connector (SATA5, J46)
33 CPU1 FAN (J30)
13 Reset Button (SW2)
34 SYS_FAN_1 (J33)
14 Power Button (SW1)
35 SSI 8-pin CPU1 Power Connector (PW3)
15 SATA0~SATA3 (J41)
36 CPU1 Socket (U2)
16 sSATA0~sSATA3 (J42)
37 Vertical Type-A USB2.0 Connector (J40)
17 USB2.0 Header (J37)
38 IPMB Pin Header (J51)
18 Front Panel Header (J50)
39 Mini-SAS HD Connector (J20/J21/J22/J23)
19 PCH SATA SGPIO Header for BB HD Board (J43)
40 ATX 24-pin Main Power Connector (PW2)
20 USB3.0 Header (J36)
41 TYAN Module Header (J48)
21 7-pin Vertical SATA3.0 Connector (SATA4, J45)
42 FAN Header for BB FAN Board (J29) 43 PSMI Pin Header (J49)
Jumpers
Slots
a COM2 or COM5 Selected Jumper (J64)
A OCP Slot for OCP Mezz Card (J26)
b COM2 or COM5 Selected Jumper (J63)
B PCI-E 3.0x8 Slot (x8 link, open-end
type, #PCIe-6.5)
c BMC Reset Header (J55)
C PCI-E 3.0x8 Slot (x8 link, open-end
type, #PCIe-6)
e NMI Jumper (J67)
D Proprietary Slot for SAS Mezz Card
(J27) for B7076G24BV4H SKU only
f ME Recovery Mode Jumper (J62)
E CPU0_DIMM_C0/C1
g ME Security Override Jumper (J60)
F CPU0_DIMM_D0/D1
26
http://www.tyan.com
G CPU0_DIMM_B0/B1
H CPU0_DIMM_A0/A1
I CPU1_DIMM_G0/G1
J CPU1_DIMM_H0/H1
K CPU1_DIMM_F0/F1
L CPU1_DIMM_E0/E1
Jumper Legend
OPEN - Jumper OFF
Without jumper cover
CLOSED - Jumper ON
With jumper cover
http://www.tyan.com
27
1.6.6 System Block Diagram
Loading...