TYAN GN70-B8236-HE Service Engineer's Manual

Page 1
1
http://www.tyan.com
GN70-B8236-HE
Service Engineer’s Manual
Page 2
2
http://www.tyan.com
Page 3
3
http://www.tyan.com
PREFACE
Copyright
This publication, including all photographs, illustrations, and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of manufacturer.
Copyright 2011 MiTAC International Corporation. All rights reserved. TYAN® is a registered trademark of MiTAC International Corporation.
Version 1.0
Disclaimer
Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and reliability prior to printing. MiTAC assumes no liability whatsoever, and disclaims any
express or implied warranty, relating to sale and/or use of TYAN® products including liability or warranties relating to fitness for a particular purpose or merchantability. MiTAC retains the right to make changes to produce descriptions and/or specifications at any time, without notice. In no event will MiTAC be held liable for any direct or indirect, incidental or consequential damage, loss of use, loss of data or other malady resulting from errors or inaccuracies of information contained in this document.
Trademark Recognition
All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including, but not limited to the following.
TYAN® is a trademark of MiTAC International Corporation. Intel
®
is a trademark of Intel® Corporation.
AMI
®
, AMIBIOS® and combinations thereof are trademarks of AMI Technologies. Microsoft®, Windows® are trademarks of Microsoft Corporation. IBM
®
, PC®, AT® and PS/2® are trademarks of IBM Corporation. Winbond
®
is a trademark of Winbond Electronics Corporation.
Page 4
4
http://www.tyan.com
FCC Declaration
Notice for the USA
Compliance Information Statement (Declaration of Conformity Procedure) DoC FCC Part 15: This device complies with part 15 of the FCC Rules
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
This device must not cause harmful interference.  This device must accept any interference received, including
interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Notice for Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.
Notice for Europe (CE Mark)
This product is in conformity with the Council Directive 2004/108/EC.
CAUTION: Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. There will be danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer. Dispose of used battery according to manufacturer instructions and in accordance with your local regulations.
Page 5
5
http://www.tyan.com
About this Manual
This manual provides you with instructions on installing your TYAN GN70-B8236-HE. This Manual is intended for experienced users and integrators with hardware knowledge of personal computers.
This manual consists of the following parts:
Chapter1:
Provides an introduction to the TYAN GN70-B8236-HE barebones, standard parts list, describes the external components, gives a table of key components, and provides block diagram of the system.
Chapter2:
Covers procedures on installing the CPU, memory modules and hard drives.
Chapter3:
Covers removal and replacement procedures for pre-installed components.
Appendix:
List the cable connection and FRU part tables for reference of system setup, and technical support in case a problem arises with your system.
Page 6
6
http://www.tyan.com
Safety and Compliance Information
Before installing and using TYAN GN70-B8236-HE, take note of the following precautions:
·Read all instructions carefully.
·Do not place the unit on an unstable surface, cart, or stand.
·Do not block the slots and opening on the unit, which are provided for
ventilation.
·Only use the power source indicated on the marking label. If you are not sure, contact the power company.
·The unit uses a three-wire ground cable, which is equipped with a third pin to ground the unit and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not support this kind of plug, contact your electrician to replace your obsolete outlet.
·Do not place anything on the power cord. Place the power cord where it will not be in the way of foot traffic.
·Follow all warnings and cautions in this manual and on the unit case.
·Do not push objects in the ventilation slots as they may touch high
voltage components and result in shock and damage to the components.
· When replacing parts, ensure that you use parts specified by the
manufacturer.
·When service or repairs have been done, perform routine safety checks to verify that the system is operating correctly.
·Avoid using the system near water, in direct sunlight, or near a heating device.
·Cover the unit when not in use.
Page 7
7
http://www.tyan.com
Safety Information
Retain and follow all product safety and operating instructions provided with your equipment. In the event of a conflict between the instructions in this guide and the instructions in equipment documentation, follow the guidelines in the equipment documentation.
Observe all warnings on the product and in the operating instructions. To reduce the risk of bodily injury, electric shock, fire and damage to the equipment, observe all precautions included in this guide.
You must become familiar with the safety information in this guide before you install, operate, or service TYAN products.
Symbols on Equipment
Caution. This symbol indicates a potential
hazard. The potential for injury exists if cautions are not observed. Consult equipment documentation for specific details.
Warning. This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
Warning. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
To reduce risk of injury from a hot component, allow the surface to cool before touching.
General Precautions
· Follow all caution and warning instructions marked on the equipment and explained in the accompanying equipment documentation.
Machine Room Environment
 · Make sure that the area in which you install the system is properly
ventilated and climate-controlled.
Page 8
8
http://www.tyan.com
· Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the electrical rating label of the equipment.
· Do not install the system in or near a plenum, air duct, radiator, or heat register.
· Never use the product in a wet location.
Equipment Chassis
· Do not block or cover the openings to the system.
· Never push objects of any kind through openings in the equipment.
Dangerous voltages might be present.
· Conductive foreign objects can produce a short circuit and cause fire, electric shock, or damage to your equipment.
· Lift equipment using both hands and with your knees bent.
Equipment Racks
To avoid injury or damage to the equipment:
· Observe local occupational health and safety requirements and guidelines for manual materials handling.
· Do not attempt to move a rack by yourself; a minimum of two people are needed to move a rack.
· Do not attempt to move a fully loaded rack. Remove equipment from the rack before moving it.
· Do not attempt to move a rack on an incline that is greater than 10 degrees from the horizontal.
· Make sure the rack is properly secured to the floor or ceiling.
· Make sure the stabilizing feet are attached to the rack if it is a
single-rack installation.
· Make sure racks are coupled together if it is a multiple-rack installation.
· Make sure the rack is level and stable before installing an appliance in
the rack.
· Make sure the leveling jacks are extended to the floor.
Page 9
9
http://www.tyan.com
· Make sure the full weight of the rack rests on the leveling jacks.
· Always load the rack from the bottom up. Load the heaviest component
in the rack first.
· Make sure the rack is level and stable before pulling a component out of the rack.
· Make sure only one component is extended at a time. A rack might become unstable if more than one component is extended.
To avoid damage to the equipment:
· The rack width and depth must allow for proper serviceability and cable management.
· Ensure that there is adequate airflow in the rack. Improper installation or restricted airflow can damage the equipment.
· The rack cannot have solid or restricted airflow doors. You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system.
· If you install the Model in a rack, do not place equipment on top of the unit. It will cause restricted airflow and might cause damage to the equipment.
·
Make sure the product is properly matted with the rails. Products that
are improperly matted with the rails might be unstable.
·
Verify that the AC power supply branch circuit that provides power to
the rack is not overloaded. This will reduce the risk of personal injury, fire, or damage to the equipment. The total rack load should not exceed 80 percent of the branch circuit rating. Consult the electrical authority having jurisdiction over your facility wiring and installation requirements.
Equipment Power Cords
· Use only the power cords and power supply units provided with your system. The system might have one or more power cords.
· Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
· In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do not ground the
Page 10
10
http://www.tyan.com
Green/Yellow tab, it can cause an electrical shock due to high leakage currents.
· Do not place objects on AC power cords or cables. Arrange them so
that no one might accidentally step on or trip over them.
· Do not pull on a cord or cable. When unplugging from the electrical outlet, grasp the cord by the plug.
· To reduce the risk of electrical shock, disconnect all power cords before servicing the appliance.
Equipment Batteries
· The system battery contains lithium manganese dioxide. If the battery pack is not handled properly, there is risk of fire and burns.
· Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or water.
· Do not expose the battery to temperatures higher than 60°C (140°F).
· The system battery is not replaceable. If the battery is replaced by an
incorrect type, there is danger of explosion. Replace the battery only with a spare designated for your product.
· Do not attempt to recharge the battery.
· Dispose of used batteries according to the instructions of the
manufacturer. Do not dispose of batteries with the general household waste. To forward them to recycling or proper disposal, use the public
collection system or return them to TYAN, your authorized TYAN partner, or their agents.
Equipment Modifications
· Do not make mechanical modifications to the system. TYAN is not responsible for the regulatory compliance of TYAN equipment that has been modified.
Equipment Repairs and Servicing
· The installation of internal options and routine maintenance and service of this product should be performed by individuals who are knowledgeable
Page 11
11
http://www.tyan.com
about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels.
· Do not exceed the level of repair specified in the procedures in the product documentation. Improper repairs can create a safety hazard.
· Allow the product to cool before removing covers and touching internal components.
· Remove all watches, rings, or loose jewelry when working before removing covers and touching internal components.
· Do not use conductive tools that could bridge live parts.
· Use gloves when you remove or replace system components; they can
become hot to the touch.
· If the product sustains damage requiring service, disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider. Examples of damage requiring service include:
– The power cord, extension cord, or plug has been damaged. – Liquid has been spilled on the product or an object has fallen into the
product. – The product has been exposed to rain or water. – The product has been dropped or damaged. – The product does not operate normally when you follow the operating
instructions.
Page 12
http://www.tyan.com
12
Page 13
http://www.tyan.com
13
Table of Contents
Chapter 1: Overview....................................................................... 15
1.1 About the TYAN GN70-B8236-HE ......................................... 15
1.2 Product Models....................................................................... 15
1.3 Features ............................................................................ 16
1.4 Standard Parts List ................................................................. 20
1.4.1 Box Contents ................................................................... 20
1.4.2 Accessories ..................................................................... 22
1.5 About the Product ................................................................... 24
1.5.1 System Front View........................................................... 24
1.5.2 System Rear View ........................................................... 27
1.5.3 Motherboard (S8236) Layout........................................... 28
1.5.4 Jumpers & Connectors .................................................... 29
1.5.5 System Block Diagram (S8236) ...................................... 30
1.5.6 Internal View .................................................................... 31
Chapter 2: Setting Up..................................................................... 33
2.0.1 Before you Begin ............................................................. 33
2.0.2 Work Area........................................................................ 33
2.0.3 Tools ................................................................................ 33
2.0.4 Precautions...................................................................... 34
2.1 Installing Motherboard Components....................................... 35
2.1.1 Removing the Chassis Cover .......................................... 35
2.1.2 Removing the Riser Card Brackets ................................. 37
2.1.3 Installing the CPU and Heatsink...................................... 38
2.1.4 Installing the Memory....................................................... 41
2.1.4 Installing Hard Drives....................................................... 46
2.1.5 Installing the PCI-E Cards ............................................... 49
2.2 Rack Mounting........................................................................ 50
2.2.1 Installing the Server in a Rack......................................... 50
Page 14
http://www.tyan.com
14
2.2.2 Removing the Server from a Rack................................ 54
Chapter 3: Replacing Pre-Installed Components ........................57
3.1 Introduction ............................................................................. 57
3.2 Disassembly Flowchart........................................................... 57
3.3 Removing the Cover ............................................................... 58
3.4 Replacing Motherboard Components..................................... 58
3.4.1 Replacing PCI-E Riser Card Cards ................................. 58
3.4.2 Disconnecting All Motherboard Cables ........................... 60
3.4.3 Removing the Motherboard ............................................. 61
3.5 Replacing the Power Distribution Board................................. 62
3.6 Replacing the Front Panel Board ........................................... 63
3.6.1 Front Panel Board Specifications .................................... 65
3.6.2 FPB LED and Connector Pin Definition........................... 66
3.7 Replacing the System Fan ..................................................... 68
3.8 Replacing the Fan Backplane Board...................................... 70
3.8.1 Fan BP Board Specifications........................................... 73
3.8.2 Fan BP Board LED Definitions ........................................ 73
3.9 Replacing the HDD Backplane Board .................................... 74
3.9.1 HDD BP Board Specifications ......................................... 75
3.9.2 HDD BP Board LED Definitions....................................... 76
Appendix I: Cable Connection Tables .......................................... 79
Appendix II: Technical Support.....................................................81
Page 15
http://www.tyan.com
15
Chapter 1: Overview
1.1 About the TYAN GN70-B8236-HE
Congratulations on your purchase of the TYAN® GN70-B8236-HE, a highly optimized rack-mountable barebone system. The GN70-B8236-HE is designed to support dual AMD
®
45nm 8-Core/12-Core Opteron 6100 Series processors
and up to 128GB RDIMM and 64GB UDIMM of DDR3 memory, providing a rich feature set and incredible performance. Leveraging advanced technology from
AMD
®
, the GN70-B8236-HE server system is capable of offering scalable 32 and 64-bit computing, high bandwidth memory design, and lightning-fast PCI-E bus implementtation. The GN70-B8236-HE not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage.
TYAN
®
also offers the GN70-B8236-HE in a version that can support up to eight
3.5” hot-swap hard drives. The GN70-B8236-HE uses TYAN’s latest chassis featuring a robust structure and a solid mechanical enclosure. All of this provides GN70-B8236-HE the power and flexibility to meet the needs of nowadays server application.
1.2 Product Models
Model HDD Bays Power supply
B8236G70W8HR Hot-swap, 8HDDs (1+1) hot-swap 770W
B8236G70W8HR-SE Hot-swap, 8HDDs (1+1) hot-swap 700W
Page 16
http://www.tyan.com
16
1.3 Features
TYAN GN70B8236 (B8236G70W8HR-HE)
Form Factor
2U Rackmount
Chassis Model
GN70
Dimension (D x W x
H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard
S8236WGM3NR-HE
Board Dimension
EEB, 12"x13" (305x330mm)
System
Gross Weight
25 kg
Buttons
(1) RST / (1) ID / (1) PWR w/ LED
LEDs
(1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports
(2) USB ports
Type / Q'ty
2.5" or 3.5" Hot-Swap / (8)
External Drive
Bay
Supported HDD
Interface
SATA-II 3.0Gb/s / SAS 6.0Gb/s
System Cooling
Configuration
FAN
(8) 6cm fans
Type
EPS1U
Efficiency
PFC / 80 plus gold
Redundancy
1+1
Input Range
Full-range AC(100-240V)
Frequency
60 Hertz
Power Supply
Output Watts
770W or 700W
Processor
Supported CPU
Series
AMD 45nm 8-Core/12-Core Opteron 6100 Series
Processors (Magny-Cours) / (3) HT3.0 support ;
12MB L3 per socket
Page 17
http://www.tyan.com
17
Socket Type / Q'ty
G34 / (2)
Average CPU
Power (ACP)
wattage
Up to 80W
System Bus
Up to 6.4 GT/s Hyper-Transport link support
Chipset
AMD SR5690 + SR5650 + SP5100
Chipset
Super I/O
Winbond W83627DHG-P
Supported DIMM
Qty
(16) DIMM slots
DIMM Type / Speed
U/RDDR3 & LV RDDR3, 800/1066/1333 MHz
Capacity
Up to 128GB RDIMM/ 64GB UDIMM
Memory channel
4 Channels per CPU
Memory
Memory voltage
1.5V or 1.35V
PCI-E
(3) PCI-E Gen.2 x16 slots
Pre-install TYAN
Riser Card
(1) M2201-L16-2F, PCI-E x16 2U riser card (left) /
(2) M2202-R16-2F, PCI-E x16 2U riser card (right)
Expansion Slots
Max. HBA
Dimension (H x L)
(6) 111.15mm x 167.65mm (FH/HL)
Port Q'ty
(3)
LAN
Controller
Intel 82574L / Intel 82576EB
Connector type
D-Sub 15-pin
Resolution
1600x1200@60Hz
Graphic
Chipset
Aspeed AST2050
USB
(4) ports (2 at front, 2 at rear)
COM
(1) DB-9 COM port
I/O Ports
VGA
(1) D-Sub 15-pin port
Page 18
http://www.tyan.com
18
RJ-45
(3) ports
Chipset
Winbond W83795G
Voltage
Monitors voltage for CPU, memory, chipset &
power supply
Temperature
Monitors temperature for CPU & system
environment
LED
Over temperature warning indicator / Fan & PSU
fail LED indicator
System
Monitoring
Others
Chassis intrusion detection / Watchdog timer
support
Onboard Chipset
Onboard Aspeed AST2050
AST2050 IPMI
Feature
IPMI 2.0 compliant baseboard management
controller (BMC) / Supports storage over IP and
remote platform-flash / BIOS update
Server
Management
AST2050 iKVM
Feature
24-bit high quality video compression / Dual
10/100 Mb/s MAC interfaces
Brand / ROM size
AMI / 4MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0
/SMBIOS2.3 /PXE boot / ACPI 2.0 power
management /Power on mode after power
recovery / User-configurable H/W monitoring /
Auto-configurable of hard disk types
Operating
System
OS supported list
Please refer to our OS supported list.
FCC (DoC)
Class A
Regulation
CE (DoC)
Yes
Operating
Operating Temp.
10° C ~ 35° C (50° F~ 95° F)
Page 19
http://www.tyan.com
19
Non-operating
Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Environment
In/Non-operating
Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6
Complaint
Yes
Barebone
(1) GN70B8236 Barebone
Manual
(1) MB User's manual + (1) BB User's manual
Installation CD
(1) TYAN installation CD
Heatsink / Cooler
(2) G34 CPU heatsinks
Rail kit
(1) CRAL-0031, sliding rail kit for KGT24/ KGT62
Mounting Ear
(1) mounting ear kit
Package
Contains
Cable Power Cord
(2) CCBL-0310, US type power cord / (2)
CCBL-0300, EU type power cord
Optional
accessories
Peripheral
(1) CDVD-0060, slim type DVD-ROM
Page 20
http://www.tyan.com
20
1.4 Standard Parts List
This section describes GN70-B8236-HE package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. The product should arrive packaged as illustrated below.
1.4.1 Box Contents
Component Description
2U chassis, (8) hot swap HDD bays
TYAN® S8236 system board (pre-installed)
(1+1) ERP1U hot-swap 770W RPSU
or
(1+1) ERP1U hot-swap 700W RPSU
(8) System fan
M1601T70-D-PDB Power Distribution Board (pre-installed)
M1245G70-BP6-8 SATA/SAS HDD Backplane Board (pre-installed)
M1709G70-FPB (pre-installed)
M2201-L16-2F riser card
(pre-installed)
Page 21
http://www.tyan.com
21
M2202-R8-2F riser card (pre-installed)
Page 22
http://www.tyan.com
22
1.4.2 Accessories
If any items are missing or appear damaged, contact your retailer or browse to TYAN
®
’s website for service: http://www.tyan.com
The web site also provides information of other TYAN
®
products, as well as
FAQs, compatibility lists, BIOS settings, etc.
TYAN® Motherboard
Drive CD
Heatsink x 2
HDD Screw Pack
(12 pcs)
Rail x 2
DVD Bracket Kit DVD Cable Kit
Ventilation Bracket GPU Cable
Page 23
http://www.tyan.com
23
SGCC Bracket_L SGCC Bracket_R
AC Power Cord 125V
(US)
AC Power Cord 250V
(Europe)
Barebone Manual Mainboard Manual
Addendum for China
Use Only
Page 24
http://www.tyan.com
24
1.5 About the Product
The following views show you the product.
1.5.1 System Front View
1 Ears
2 3.5” HDD bays
3 USB Ports
4 ID Button
5 NMI Button
6 RESET Button
7 NIC1/NIC2/NIC3
8 ID LED
9 Warning LED
10 BMC LED (reserved)
11 Power On/OFF Button with LED
Page 25
http://www.tyan.com
25
LED Definitions
LED State Color Description
On Green System is turned on
Blinking Green System is under S1 or S3 state
Power LED
Off Off Power off Blinking Green LAN active On Green LAN linked
NIC1
off off LAN not linked Blinking Green LAN active On Green LAN linked
NIC2
off off LAN not linked
Blinking Green LAN active
On Green LAN linked
NIC3
off off LAN not linked
On Red
Fan fail /Over temperature /Over voltage
Warning LED
Off Off No failure On Blue System identified
ID LED
Off Off System not identified
Page 26
http://www.tyan.com
26
HDD LED
HDD Status Status LED
Color: Amber
Activity LED
Color: Green
No Driver Present or power disconnected OFF OFF
No Activity OFF ONDriver Present
Access Activity OFF Blinking
HDD Fail On Solid OFF
Identify (Locate the HDD) Blinking(1Hz) x
SAS/SATA RAID Building Blinking(4Hz) x
Page 27
http://www.tyan.com
27
1.5.2 System Rear View
1 Power Supply
2 LAN3 (shared with IPMI) + 2 USB
3 COM Port
4 LAN1 + LAN2
5 ID LED
6 VGA Port
7 PCI-E Slots
LAN LED
LED State Color Description
On Green
10Mb/100Mb/1000Mb linked
Blinking Green
10Mb/100Mb/1000Mb activity
RJ-45 Activity(left)
Disabled
Flash Green
No LAN linked
On Amber 1000Mb linked
On Green 100Mb linked
RJ-45 Linkage(Right)
Disabled Off
10Mb mode or No LAN linked
NOTE: “Left” and “Right” are viewed from the rear panel.
ID LED
LED State Color Description
On Blue System identified
ID LED
Off Off System not identified
Page 28
http://www.tyan.com
28
1.5.3 Motherboard (S8236) Layout
The diagram is representative of the latest board revision available at the time of publishing. The board you receive may not look exactly like the above diagram.
Page 29
http://www.tyan.com
29
1.5.4 Jumpers & Connectors
Jumper/Connector Function
J4 COM2 Header J5/J12/J30/J34/J54/J55/J56 4-pin Fan Connectors J23 Front Panel Header J24 Reset Switch J25 Power Switch J28 Fan TACH Connector J29/J33 USB Front Panel Header J31 PSMI Connector J32 LAN3 Active LED Header J53 HDD Fault Header J59 IPMB Header JP1/JP2 COM2 Function Select Jumper JP3 Clear CMOS Jumper JP6 Front Panel ID LED Button JP7 Chassis Intrusion Header LED1 ID LED LED2 SAS Flash Ready (Amber) LED3 SAS HD Fault LED (Amber) LED4 Power On LED (Green) LED5 Standby LED (Green) LED6 SAS Error LED (Amber) LED7 SAS Heart Beat LED (Green) LED8 BMC Heart Beat LED (Green)
Jumper Legend
OPEN - Jumper OFF Without jumper cover
CLOSED - Jumper ON With jumper cover
Page 30
http://www.tyan.com
30
1.5.5 System Block Diagram (S8236)
Page 31
http://www.tyan.com
31
1.5.6 Internal View
With Riser Card Brackets
1 3.5” HDD cage (underneath) 2 SAS/SATA HDD Backplane Board 3 System Fan Unit 4 Power Distribution Board 5 PCI-E Riser Card Bracket 6 Power Supply (underneath)
Page 32
http://www.tyan.com
32
Without Riser Card Brackets
1 3.5” HDD cage (underneath) 2 SAS/SATA HDD Backplane Board 3 System Fan Unit 4 Power Distribution Board 5 Power Supply (underneath)
Page 33
http://www.tyan.com
33
Chapter 2: Setting Up
2.0.1 Before you Begin
This chapter explains how to install the CPUs, CPU heatsinks, memory modules, and hard drives. Instructions on inserting add on cards are also given.
2.0.2 Work Area
Make sure you have a stable, clean working environment. Dust and dirt can get into components and cause malfunctions. Use containers to keep small components separated. Putting all small components in separate containers prevents them from becoming lost. Adequate lighting and proper tools can prevent you from accidentally damaging the internal components.
2.0.3 Tools
The following procedures require only a few tools, including the following:
A cross head (Phillips) screwdriver
A grounding strap or an anti-static pad
Most of the electrical and mechanical connections can be disconnected with your hands. It is recommended that you do not use pliers to remove connectors as it may damage the soft metal or plastic parts of the connectors.
Page 34
http://www.tyan.com
34
2.0.4 Precautions
Components and electronic circuit boards can be damaged by discharges of static electricity. Working on a system that is connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to GN70-B8236-HE or injury to yourself.
Ground yourself properly before removing the top cover of the
system. Unplug the power from the power supply and then touch a safely grounded object to release static charge (i.e. power supply case). If available, wear a grounded wrist strap. Alternatively, discharge any static electricity by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appliance.
Avoid touching motherboard components, IC chips, connectors,
memory modules, and leads.
The motherboard is pre-installed in the system. When
removing the motherboard, always place it on a grounded anti-static surface until you are ready to reinstall it.
Hold electronic circuit boards by the edges only. Do not touch
the components on the board unless it is necessary to do so. Do not flex or stress circuit boards.
Leave all components inside the static-proof packaging that
they ship with until they are ready for installation.
After replacing optional devices, make sure all screws, springs,
or other small parts are in place and are not left loose inside the case. Metallic parts or metal flakes can cause electrical shorts.
CAUTION: Please note that the following illustrations may not look
exactly like the rackmount server you purchased. Therefore, the illustrations should be held for your reference only.
Page 35
http://www.tyan.com
35
2.1 Installing Motherboard Components
This section describes how to install components on to the motherboard, including CPUs, memory modules, HDD and PCI-E cards.
2.1.1 Removing the Chassis Cover
Follow these instructions to remove the GN70-B8236-HE chassis cover.
1 Unscrew the rear top cover on the back side.
2 Unscrew the front top cover and pull the latches aside to lift up the top
cover.
Page 36
http://www.tyan.com
36
3 Slide the rear top cover out.
Page 37
http://www.tyan.com
37
2.1.2 Removing the Riser Card Brackets
Follow these instructions to remove the PCI-E Riser Card Brackets.
1 Loose four thumb screws to release the PCI-E Riser Card Brackets.
2 Lift up the Riser Card Brackets.
Page 38
http://www.tyan.com
38
2.1.3 Installing the CPU and Heatsink
Follow the steps below on installing CPUs and CPU heatsinks.
1. Locate the CPU sockets.
2. Pull the lever slightly away from the socket and then push it to a fully open position.
3. Push the CPU socket cover to a fully open position.
Page 39
http://www.tyan.com
39
4. Take out the protection cap.
5. Place the CPU into the socket and make sure that the gold arrow is located in the right direction.
6. Close the CPU socket cover and press the lever down to secure the CPU.
Page 40
http://www.tyan.com
40
7. Position the heatsink on top of the CPU and secure it with 2 screws.
8. Repeat the procedures mentioned earlier to install the second CPU and heatsink.
Page 41
http://www.tyan.com
41
2.1.4 Installing the Memory
Follow these instructions to install the memory modules onto the motherboard.
1. Locate the memory slots on the motherboard.
2. Press the memory slot locking levers in the direction of the arrows as shown in
the following illustration.
3. Align the memory module with the slot. When inserted properly, the memory slot locking levers lock automatically onto the indentations at the ends of the module. Follow the recommended memory population table to install the other memory modules.
Page 42
http://www.tyan.com
42
Memory Population Option Table
The following pictures show common types of DDR3 memory modules.
Page 43
http://www.tyan.com
43
Recommended Memory Population Table
Single CPU
Installed
(CPU0 only)
Dual CPU
installed
(CPU0 and CPU1)
Quantity of
memory installed
12346823 4567810121416
CPU0_DIMM(1)D0
CPU0_DIMM(2)D1
CPU0_DIMM(3)C0
CPU0_DIMM(4)C1
CPU0_DIMM(5)B0
CPU0_DIMM(6)B1
CPU0_DIMM(7)A0
CPU0_DIMM(8)A1
CPU1_DIMM(9)D0
CPU1_DIMM(10)D1
CPU1_DIMM(11)C0
CPU1_DIMM(12)C1
CPU1_DIMM(13)B0
CPU1_DIMM(14)B1
CPU1_DIMM(15)A0
CPU1_DIMM(16)A1
NOTE:
1. indicates a populated DIMM slot.
2. Paired memory installation for Max performance.
3. Populate the same DIMM type in each channel, specifically
- Use the same DIMM size
- Use the same # of ranks per DIMM
4. Dual-rank DIMMs are recommended over single-rank DIMMs
5. Un-buffered DIMM can offer slightly better performance than registerd DIMM if
populating only a single DIMM per channel
6. We don't suggest other memory installation.
7. AMD 6100 series CPU doesn't support Quad-ranks U-DIMM
Page 44
http://www.tyan.com
44
U-DIMM Module Support
DDR3 Speed/Voltage
DDR3 Rank
Configuration
1.35v 1.5v
DIMM1
(A1, B1,
C1, D1)
DIMM0 (A0, B0, C0, D0)
800MHz 800MHz
SR and
DR
n/a
800MHz 800MHz
SR and
DR
SR and
DR
1066MHz 1066MHz
SR and
DR
n/a
1066MHz 1066MHz
SR and
DR
SR and
DR
1066MHz 1333MHz
SR and
DR
n/a
1066MHz 1333MHz
SR and
DR
SR and
DR
Notes:
U-DIMM can support up to 4GB sized DIMM’s  Maximum of 8GB per channel  SR and DR UDDR3 module support only x8 DRAM module support only SR and DR 1.35v Memory MAX speed of 1066MHz in a dual channel configuration  SR and DR 1.5v Memory MAX speed of 1333MHz in a dual channel configuration
Page 45
http://www.tyan.com
45
R-DIMM Module Support
DDR3 Speed/Voltage DDR3 Rank Configuration
1.35v 1.5v
DIMM1 (A1,
B1, C1, D1)
DIMM0 (A0,
B0, C0, D0)
800MHz 800MHz SR and DR n/a
800MHz 800MHz QR n/a
800MHz 800MHz
SR, DR and
QR
SR, DR and
QR
1066MHz 1066MHz SR and DR n/a
1066MHz 1066MHz QR n/a
1066MHz 1066MHz SR and DR SR and DR
n/a 1066MHz QR
SR, DR and
QR
n/a 1333MHz SR and DR n/a
n/a 1333MHz QR n/a
Notes:
RDIMM can support up to 16GB sized DIMM’s  SR and DR Memory has a MAX amount of 16GB per channel  SR and DR 1.35v Memory MAX speed of 1066MHz in a dual channel
configuration
SR and DR 1.5v Memory MAX speed of 1333MHz in a dual channel
configuration
QR Memory has a MAX amount of 32GB per channel  QR 1.35v Memory MAX speed of 800MHz in a dual channel configuration  QR 1.5v Memory MAX speed of 1066MHz in a dual channel configuration
Page 46
http://www.tyan.com
46
2.1.4 Installing Hard Drives
The GN70-B8236-HE can support up to eight (8) 3.5” hard drives. Follow these instructions to install a hard drive.
Warning!!! Always install the hard disk drive to the chassis after the chassis is
secured on the rack.
1 Press the locking lever latch and pull the locking lever open.
2 Slide the HDD tray out.
Page 47
http://www.tyan.com
47
3 Remove the 6 screws.
4 Place a hard drive into the drive tray.
5 Use 6 HDD screws to secure the HDD.
Page 48
http://www.tyan.com
48
6 Reinsert the HDD tray into the chassis and press the locking lever to
secure the tray.
Page 49
http://www.tyan.com
49
2.1.5 Installing the PCI-E Cards
The GN70-B8236-HE supports three PCI-E Riser Card Brackets. Follow these instructions to install PCI-E cards.
1 Unscrew the PCI-E slots to take out the PCI brackets.
2 Insert the PCI-E cards and securely screw as shown.
3 Repeat the same procedures for the second and third Riser Card Brackets.
Page 50
50
http://www.tyan.com
2.2 Rack Mounting
After installing the necessary components, the TYAN GN70-B8236-HE can be mounted in a rack using the supplied rack mounting kit.
Rear view Sliding Rail x 2 Front view
2.2.1 Installing the Server in a Rack
Follow these instructions to mount the TYAN GN70-B8236-HE into an industry standard 19” rack.
NOTE: Before mounting the TYAN GN70-B8236-HE in a rack, ensure that all
internal components have been installed and that the unit has been fully tested. However, to make the installation easier, we suggest that you remove all HDD trays before you insert the chassis to the rack.
1. Position the rear of the sliding rail to the rear side of the rack. Make sure the mid-point of the rail align with the anchor point marked in red.
Rear
Page 51
51
http://www.tyan.com
2. Repeat the same procedures for the front end of the rail.
Front
3. Push the locking latch to secure the rail to the rack. Repeat the same procedures for the other rail.
Left Right
Page 52
52
http://www.tyan.com
4. Slide the inner rail to its full length. Note that to slide to its full length, push the locking tab of the rail upward and then the rail can slide freely. There are three holes on each rail which are used to hook and secure the chassis.
5. Align the studs on the chassis with the holes on the rails and make sure the chassis is securely hooked.
Page 53
http://www.tyan.com
53
6. Push the chassis back into the rack.
7. The installation is now complete.
Page 54
http://www.tyan.com
54
2.2.2 Removing the Server from a Rack
Follow these instructions to remove the TYAN GN70-B8236-HE from an industry standard 19” rack.
1. Push the ears to pull the chassis forward.
2. Push forward the locking tabs on both rails to unhook the chassis from the rails.
Page 55
http://www.tyan.com
55
3. Follow the steps described earlier in reverse to remove the chassis from the rack.
NOTE:
To avoid injury, it is strongly recommended that at least two people lift the TYAN GN70-B8236-HE to hook on or unhook from the rails.
Page 56
http://www.tyan.com
56
NOTE
Page 57
http://www.tyan.com
57
Chapter 3: Replacing Pre-Installed
Components
3.1 Introduction
This chapter explains how to replace the pre-installed components, including the S8236 Motherboard, M1709G70-FPB Front Panel Board, PCI-E Riser Card, M1245G70-BP6-8 SATA/SAS HDD Board, System Fan and Power Supply Unit etc.
3.2 Disassembly Flowchart
The following flowchart outlines the disassembly procedure.
Page 58
http://www.tyan.com
58
3.3 Removing the Cover
Before replacing any parts you must remove the chassis cover. Follow Section
2.1.1 Removing the Chassis Cover (page 35) to remove the cover of the GN70-B8236-HE.
3.4 Replacing Motherboard Components
Follow these instructions to replace motherboard components, including the motherboard.
3.4.1 Replacing PCI-E Riser Card Cards
The GN70-B8236-HE has three pre-installed PCI-E×16 riser cards. Follow the instructions below to disassemble the M2201-L16-2F and M2202-F16-2F PCI-E riser cards.
1 Unscrew to take out the PCI-E cards.
2 Unscrew the M2201-L16-2F riser card to replace a new one if necessary.
Page 59
http://www.tyan.com
59
3 Repeat the same procedures for the second and third Riser Card Brackets.
4 Unscrew the M2202-F16-2F riser card to replace a new one if necessary.
Page 60
http://www.tyan.com
60
3.4.2 Disconnecting All Motherboard Cables
Before replacing the motherboard or certain components, remove cables connected to the motherboard. Follow these instructions to remove all cables.
1 Disconnect the power and PSMI cables.
2 Disconnect the Mini SAS, USB, fan control and front panel cables.
3 Disconnect the power cable.
Page 61
http://www.tyan.com
61
3.4.3 Removing the Motherboard
After removing all of the aforementioned cables, follow the instructions below to remove the motherboard from the chassis.
1 Remove the heatsinks and processors if installed. 2 Remove the nine screws securing the motherboard to the chassis.
3 Carefully lift the motherboard from the chassis.
Page 62
http://www.tyan.com
62
3.5 Replacing the Power Distribution Board
Follow these instructions to replace the M1601T70-D-PDB power distribution board.
1 Disconnect all cables.
2 Unscrew to replace a new power distribution board.
Page 63
http://www.tyan.com
63
3.6 Replacing the Front Panel Board
Follow these instructions to replace the M1709G70-FPB Front Panel Board.
1 Unscrew to release the Front Panel Board Module.
2 Push the Front Panel Board Module forward.
3 Disconnect the Front Panel Control and USB cables.
4 Unscrew the Front Panel Board to replace a new one.
Page 64
http://www.tyan.com
64
5 Follow the steps described earlier in reverse to reinstall the Front Panel
Board.
Page 65
http://www.tyan.com
65
3.6.1 Front Panel Board Specifications
Form Factor
18.5MMx44.2MM, 4-Layer PCB
Connectors
One 2x15 pin header for front panel connector of
motherboard and HDD backplane board
LEDs
Power On/Off LED Color: Green (after power on) ID LED Color: Blue Warning (IPMI) LED Dual Color:
Yellow (Warning) / Green(Normal)
Push buttons
RESET button ID button Power On/Off button with Power On/Off LED
Page 66
http://www.tyan.com
66
3.6.2 FPB LED and Connector Pin Definition
LED State Color Description
On Green System is turned on
Blinking Green System is under S1 or S3 state
Power On/Off LED
Off Off Power off
On Orange
Fan fail / Over temperature / Over Voltage / PSU fail
Warning (IPMI) LED
On Green No failure
On Blue
System identified remotely on the server, by clicking the Chassis Locate LED key.*
ID LED
Off Off System not identified
*: For more information on the Chassis Locate LED, please visit our Web site for the latest Pilot II Software Configuration Guide.
Front Panel Connector (J3)
Definition Pin Pin Definition
PW_LED+
1 2
VCC
Key
3 4
ID_LED+
PW_LED-
5 6
ID_LED-
HD/LAN3_LED+
7 8
SYS_FAULT1-
HD/LAN3_LED-
9 10
SYS_FAULT2-
PWR_SW+
11 12
LAN1_LED+
PWR_SW-
13 14
LAN1_LED-
RESET+
15 16
ICH_SMBDAT
RESET-
17 18
ICH_SMBCLK
ID_SW+
19 20
INTRU#
Temp_sensor
21 22
LAN2_LED+
EXT_INT
23 24
LAN2_LED-
Page 67
http://www.tyan.com
67
USB Connector (J1)
Definition Pin Pin Definition
VCC
1 2
VCC
USB1-
3 4
USB2-
USB1+
5 6
USB2+
GND
7 8
GND
KEY
9 10
GND
Page 68
http://www.tyan.com
68
3.7 Replacing the System Fan
Follow these instructions to replace the system fan.
1 Press the latch in the direction as shown to lift up the fan from cage.
2 Take out the fan unit.
3 Loose the screws on both sides.
Page 69
http://www.tyan.com
69
4 Push the latch in the direction as the arrow shown to release the fan from the iron holder.
5 Remove the iron holder to replace a new fan.
6 After replacing a new one, put the fan unit back into the cage.
Page 70
http://www.tyan.com
70
3.8 Replacing the Fan Backplane Board
Follow these instructions to replace the Fan Backplane Board in your system.
1 Press the latch in the direction as shown to lift up the fan from cage.
2 Remove all eight fans from the chassis.
Page 71
http://www.tyan.com
71
3 Disconnect all cables attached to the Fan Backplane Board.
4 Use a screw driver to unscrew the Fan Module.
5 Disconnect the power and fan cables.
6 Lift up the Fan Module.
Page 72
http://www.tyan.com
72
7 Release the 14 screws on the Fan Backplane Board to replace a new
one.
8 Follow the steps described in reverse order to reinstall the fan cage.
Page 73
http://www.tyan.com
73
3.8.1 Fan BP Board Specifications
Form Factor
254 mm x 82 mm, 4-layer PCB
Integrated I/O
(2) 1x4pin R/A Power Connector (8) 2x2pin Fan Connectors (1) 2 x10pin Barebone Fan Connector (1) 2x2pin Connector for S7015
3.8.2 Fan BP Board LED Definitions
FAN Status Green LED Red LED
With Fan On Off
Without Fan Off On
Page 74
http://www.tyan.com
74
3.9 Replacing the HDD Backplane Board
Follow these instructions to replace the SATA/SAS HDD Backplane Board.
1 Refer to Section 3.8 Replacing the Fan Backplane Board for how to remove the Fan Module. Disconnect the power cables attached to the HDD BP Board.
2 Unscrew the HDD BP Board. Remove the HDD BP Board from the hook.
3 Replace a new HDD BP Board and reinstall it into the chassis following the steps in reverse.
Page 75
http://www.tyan.com
75
3.9.1 HDD BP Board Specifications
Front View
Rear View (with mylar)
Form Factor
81.8 x 436 mm, 4-layer PCB
Integrated I/O
8 SAS HDD Connectors 2 Mini SAS Connectors to MB and RAID Card 1 2 x 4-pin Power Connector
LEDs
8 HDD active LEDs 8 HDD fault LEDs
PW3 Pin definition
Definition Pin Pin Definition
GND 1 5 +12V GND 2 6 +12V GND 3 7 +12V GND 4 8 +12V
Page 76
http://www.tyan.com
76
3.9.2 HDD BP Board LED Definitions
HDD Status Status LED
2/4/6/8
Color: Amber
Activity LED
1/3/5/7
Color: Green
No Driver Present or power disconnected OFF OFF
No Activity OFF ONDriver Present
Access Activity OFF Blinking
HDD Fail On Solid OFF
Identify (Locate the HDD) Blinking(4Hz) x
SAS/SATA RAID Building Blinking(1Hz) x
NOTE: If the LSI 9280-l6i4e or 9260-l6i storage cards is installed, the LED status
will change as below:
Identify (Locate the HDD) Blinking(4Hz) ON
SAS/SATA RAID Building Blinking Blinking
Page 77
http://www.tyan.com
77
3.10 Replacing the Power Supply
1 Press and hold the latch to pull the power supply out.
2 After replacing a new power supply, press and hold the latch to push the
power supply back into the chassis.
Page 78
http://www.tyan.com
78
NOTE
Page 79
http://www.tyan.com
79
Appendix I: Cable Connection Tables
1. Mini-SAS Cables
SAS/SATA Backplane
M1245G70-BP6
Connects to Motherboard
SAS_1
J17
SAS_2
J11
2. FAN Control Cable
FAN Board
M1806G70-FB
Connects to Motherboard
J8
J28
3. Front Panel Control Cable
Front Panel Board
M1709G70-FPB
Connects to Motherboard
J3
J23
4. USB Cable
Front Panel Board
M1709G70-FPB
Connects to Motherboard
J1
J33
5. Power Cables
Power Board
M1601T70-D-PDB
Connects to Motherboard
PW1 (MB)
PW1
PATX1 (MB1)
PW2
Page 80
http://www.tyan.com
80
PATX2 (MB2)
PW3
J7 (PSMI)
J31
Power Board
M1601T70-D-PDB
Connects to
FAN Board
M1806G70-FB
PW4 (FAN BD1)
PW2
PW5 (FAN BD2)
PW1
Power Board
M1601T70-D-PDB
Connects to
SAS/SATA Backplane
M1245G70-BP6
PATX8 (HDD BP3)
PW1
Page 81
http://www.tyan.com
81
Appendix II: Technical Support
If a problem arises with your system, you should first turn to your dealer for direct support. Your system has most likely been configured or designed by them and they should have the best idea of what hardware and software your system contains. Hence, they should be of the most assistance for you. Furthermore, if you purchased your system from a dealer near you, take the system to them directly to have it serviced instead of attempting to do so yourself (which can have expensive consequence).
If these options are not available for you then MiTAC International Corporation can help. Besides designing innovative and quality products for over a decade, MiTAC has continuously offered customers service beyond their expectations. TYAN’s website (http://www.tyan.com) provides easy-to-access resources such as in-depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis, memory and much more. With all these convenient resources just a few keystrokes away, users can easily find their latest software and operating system components to keep their systems running as powerful and productive as possible. MiTAC also ranks high for its commitment to fast and friendly customer support through email. By offering plenty of options for users, MiTAC serves multiple market segments with the industry’s most competitive services to support them.
Please feel free to contact us directly for this service at tech-support@tyan.com
Help Resources:
1. See the beep codes section of this manual.
2. See the TYAN’s website for FAQ’s, bulletins, driver updates, and other information: http://www.tyan.com
3. Contact your dealer for help before calling TYAN.
4. Check the TYAN user group: alt.comp.periphs.mainboard.TYAN
Page 82
http://www.tyan.com
82
Returning Merchandise for Service
During the warranty period, contact your distributor or system vendor FIRST for any product problems. This warranty only covers normal customer use and does not cover damages incurred during shipping or failure due to the alteration, misuse, abuse, or improper maintenance of products.
NOTE:
A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered. You may obtain service by calling the manufa-
-cturer for a Return Merchandise Authorization (RMA) nu-
-mber. The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid. TYAN will pay to have the board shipped back to you.
TYAN® GN70-B8236-HE Service Engineer’s Manual V1.00
Document No.: D2124-100
Loading...