TYAN GN70-B7056 Service Engineer's Manual

1
http://www.tyan.com
GN70-B7056
Service Engineer’s Manual
2
http://www.tyan.com
3
http://www.tyan.com
PREFACE
Copyright
This publication, including all photographs, illustrations, and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of manufacturer.
Copyright 2012 MiTAC International Corporation. All rights reserved. TYAN
®
is
a registered trademark of MiTAC International Corporation.
Version 1.0
Disclaimer
Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and reliability prior to printing. MiTAC assumes no liability whatsoever, and disclaims any express or implied
warranty, relating to sale and/or use of TYAN
®
products including liability or warranties relating to fitness for a particular purpose or merchantability. MiTAC retains the right to make changes to produce descriptions and/or specifications at any time, without notice. In no event will MiTAC be held liable for any direct or indirect, incidental or consequential damage, loss of use, loss of data or other malady resulting from errors or inaccuracies of information contained in this document.
Trademark Recognition
All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including, but not limited to the following.
TYAN® is a trademark of MiTAC International Corporation. Intel® is a trademark of Intel® Corporation. AMI
®
, AMIBIOS® and combinations thereof are trademarks of AMI Technologies. Microsoft®, Windows® are trademarks of Microsoft Corporation. IBM®, PC®, AT® and PS/2® are trademarks of IBM Corporation. Winbond® is a trademark of Winbond Electronics Corporation.
4
http://www.tyan.com
FCC Declaration
Notice for the USA
Compliance Information Statement (Declaration of Conformity Procedure) DoC FCC Part 15: This device complies with part 15 of the FCC Rules
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
z This device must not cause harmful interference. z This device must accept any interference received, including
interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Notice for Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.
Notice for Europe (CE Mark)
This product is in conformity with the Council Directive 2004/108/EC.
CAUTION: Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. There will be danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer. Dispose of used battery according to manufacturer instructions and in accordance with your local regulations.
5
http://www.tyan.com
About this Manual
This manual provides you with instructions on installing your TYAN GN70-B7056. This Manual is intended for experienced users and integrators with hardware knowledge of personal computers.
This manual consists of the following parts:
Chapter1:
Provides an introduction to the TYAN GN70-B7056 barebones, standard parts list, describes the external components, gives a table of key components, and provides block diagram of the system.
Chapter2:
Covers procedures on installing the processor, memory modules and hard drives.
Chapter3:
Covers the removal and replacement procedures for pre-installed components.
Appendix:
List the cable connection and FRU part tables for reference of system setup, and technical support in case a problem arises with your system.
6
http://www.tyan.com
Safety and Compliance Information
Before installing and using TYAN GN70-B7056, take note of the following precautions:
gRead all instructions carefully.
gDo not place the unit on an unstable surface, cart, or stand.
gDo not block the slots and opening on the unit, which are provided for
ventilation.
g Only use the power source indicated on the marking label. If you are not
sure, contact the power company.
gThe unit uses a three-wire ground cable, which is equipped with a third pin to
ground the unit and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not support this kind of plug, contact your electrician to replace your obsolete outlet.
gDo not place anything on the power cord. Place the power cord where it will
not be in the way of foot traffic.
gFollow all warnings and cautions in this manual and on the unit case.
gDo not push objects in the ventilation slots as they may touch high voltage
components and result in shock and damage to the components.
g When replacing parts, ensure that you use parts specified by the
manufacturer.
gWhen service or repairs have been done, perform routine safety checks
to verify that the system is operating correctly.
gAvoid using the system near water, in direct sunlight, or near a heating
device.
gCover the unit when not in use.
7
http://www.tyan.com
Safety Information
Retain and follow all product safety and operating instructions provided with your equipment. In the event of a conflict between the instructions in this guide and the instructions in equipment documentation, follow the guidelines in the equipment documentation.
Observe all warnings on the product and in the operating instructions. To reduce the risk of bodily injury, electric shock, fire and damage to the equipment, observe all precautions included in this guide.
You must become familiar with the safety information in this guide before you install, operate, or service TYAN products.
Symbols on Equipment
Caution. This symbol indicates a potential
hazard. The potential for injury exists if cautions are not observed. Consult equipment documentation for specific details.
Warning. This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
Warning. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
To reduce risk of injury from a hot component, allow the surface to cool before touching.
General Precautions
gFollow all caution and warning instructions marked on the equipment and explained in the accompanying equipment documentation.
Machine Room Environment
 gMake sure that the area in which you install the system is properly
ventilated and climate-controlled.
8
http://www.tyan.com
gEnsure that the voltage and frequency of your power source match the voltage and frequency inscribed on the electrical rating label of the equipment.
g Do not install the system in or near a plenum, air duct, radiator, or heat register.
g Never use the product in a wet location.
Equipment Chassis
gDo not block or cover the openings to the system.
g Never push objects of any kind through openings in the equipment.
Dangerous voltages might be present.
g Conductive foreign objects can produce a short circuit and cause fire, electric shock, or damage to your equipment.
g Lift equipment using both hands and with your knees bent.
Equipment Racks
To avoid injury or damage to the equipment:
g Observe local occupational health and safety requirements and guidelines for manual materials handling.
g Do not attempt to move a rack by yourself; a minimum of two people are needed to move a rack.
g Do not attempt to move a fully loaded rack. Remove equipment from the rack before moving it.
g Do not attempt to move a rack on an incline that is greater than 10 degrees from the horizontal.
g Make sure the rack is properly secured to the floor or ceiling.
g Make sure the stabilizing feet are attached to the rack if it is a single-rack
installation.
g Make sure racks are coupled together if it is a multiple-rack installation.
g Make sure the rack is level and stable before installing an appliance in the
rack.
g Make sure the leveling jacks are extended to the floor.
9
http://www.tyan.com
g Make sure the full weight of the rack rests on the leveling jacks.
g Always load the rack from the bottom up. Load the heaviest component in
the rack first.
g Make sure the rack is level and stable before pulling a component out of the rack.
g Make sure only one component is extended at a time. A rack might become unstable if more than one component is extended.
To avoid damage to the equipment:
gThe rack width and depth must allow for proper serviceability and cable management.
gEnsure that there is adequate airflow in the rack. Improper installation or restricted airflow can damage the equipment.
g The rack cannot have solid or restricted airflow doors. You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system.
g If you install the Model in a rack, do not place equipment on top of the unit. It will cause restricted airflow and might cause damage to the equipment.
g
Make sure the product is properly matted with the rails. Products that are
improperly matted with the rails might be unstable.
g Verify that the AC power supply branch circuit that provides power to the
rack is not overloaded. This will reduce the risk of personal injury, fire, or damage to the equipment. The total rack load should not exceed 80 percent of the branch circuit rating. Consult the electrical authority having jurisdiction over your facility wiring and installation requirements.
Equipment Power Cords
gUse only the power cords and power supply units provided with your system. The system might have one or more power cords.
g Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
g In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do not ground the Green/Yellow tab, it can cause an electrical shock due to high leakage currents.
g
Do not place objects on AC power cords or cables. Arrange them so that no
10
http://www.tyan.com
one might accidentally step on or trip over them.
g Do not pull on a cord or cable. When unplugging from the electrical outlet, grasp the cord by the plug.
gҏ To reduce the risk of electrical shock, disconnect all power cords before servicing the appliance.
Equipment Batteries
gThe system battery contains lithium manganese dioxide. If the battery pack is not handled properly, there is risk of fire and burns.
g Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or water.
g Do not expose the battery to temperatures higher than 60°C (140°F).
g The system battery is not replaceable. If the battery is replaced by an
incorrect type, there is danger of explosion. Replace the battery only with a spare designated for your product.
g Do not attempt to recharge the battery.
g Dispose of used batteries according to the instructions of the manufacturer.
Do not dispose of batteries with the general household waste. To forward them to recycling or proper disposal, use the public collection system or return them to TYAN, your authorized TYAN partner, or their agents.
Equipment Modifications
gDo not make mechanical modifications to the system. TYAN is not responsible for the regulatory compliance of TYAN equipment that has been modified.
Equipment Repairs and Servicing
gThe installation of internal options and routine maintenance and service of this product should be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels.
g Do not exceed the level of repair specified in the procedures in the product documentation. Improper repairs can create a safety hazard.
g Allow the product to cool before removing covers and touching internal
11
http://www.tyan.com
components.
g Remove all watches, rings, or loose jewelry when working before removing covers and touching internal components.
g Do not use conductive tools that could bridge live parts.
g Use gloves when you remove or replace system components; they can
become hot to the touch.
g If the product sustains damage requiring service, disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider. Examples of damage requiring service include:
– The power cord, extension cord, or plug has been damaged. – Liquid has been spilled on the product or an object has fallen into the
product. – The product has been exposed to rain or water. – The product has been dropped or damaged. – The product does not operate normally when you follow the operating
instructions.
http://www.tyan.com
12
http://www.tyan.com
13
Table of Contents
Chapter 1: Overview....................................................................... 15
1.1 About the TYAN GN70-B7056 ............................................... 15
1.2 Product Models....................................................................... 15
1.3 Features ............................................................................ 16
1.4 Standard Parts List................................................................. 23
1.4.1 Box Contents................................................................... 23
1.4.2 Accessories ..................................................................... 24
1.5 About the Product................................................................... 26
1.5.1 System Front View .......................................................... 26
1.5.2 System Rear View........................................................... 29
1.5.3 Motherboard (S7056) Layout .......................................... 31
1.5.4 Jumpers & Connectors.................................................... 32
1.5.5 System Block Diagram (S7056) ...................................... 33
1.5.6 Internal View.................................................................... 34
Chapter 2: Setting Up..................................................................... 37
2.0.1 Before you Begin............................................................. 37
2.0.2 Work Area........................................................................ 37
2.0.3 Tools................................................................................ 37
2.0.4 Precautions...................................................................... 38
2.1 Installing Motherboard Components ...................................... 39
2.1.1 Removing the Chassis Cover.......................................... 39
2.1.2 Removing the Riser Card Brackets ................................. 41
2.1.3 Installing the CPU and Heatsink...................................... 42
2.1.4 Installing the Memory ...................................................... 45
2.1.4 Installing Hard Drives ...................................................... 51
2.1.5 Installing the PCI-E Cards ............................................... 54
2.2 Rack Mounting........................................................................ 56
2.2.1 Installing the Server in a Rack......................................... 56
2.2.2 Removing the Server from a Rack .................................. 60
Chapter 3: Replacing Pre-Installed Components ........................ 61
3.1 Introduction............................................................................. 61
3.2 Disassembly Flowchart........................................................... 61
3.3 Removing the Cover............................................................... 62
3.4 Replacing Motherboard Components..................................... 62
3.4.1 Replacing the PCH Upgrade ROM Kit ............................ 62
3.4.2 Replacing PCI-E Riser Card Cards ................................. 64
3.4.3 Disconnecting All Motherboard Cables ........................... 66
3.4.4 Removing the Motherboard............................................. 67
3.5 Replacing the Power Distribution Board................................. 68
http://www.tyan.com
14
3.6 Replacing the Front Panel Board ........................................... 69
3.6.1 Front Panel Board Specifications.................................... 71
3.6.2 Connector Pin Definition.................................................. 72
3.7 Replacing the System Fan ..................................................... 73
3.8 Replacing the Fan Backplane Board...................................... 75
3.8.1 Fan BP Board Specifications........................................... 78
3.8.2 Fan BP Board LED Definitions........................................ 78
3.8.3 Connector Pin Definitions................................................ 79
3.9 Replacing the HDD Backplane Board .................................... 80
3.9.1 HDD BP Board Specifications......................................... 81
Appendix I: Cable Connection Tables .......................................... 83
Appendix II: FRU Parts Table ........................................................ 85
Appendix III: Fan and Temp Sensors ........................................... 87
Appendix IV: Technical Support ................................................... 91
http://www.tyan.com
15
Chapter 1: Overview
1.1 About the TYAN GN70-B7056
Congratulations on your purchase of the TYAN
®
GN70-B7056, a highlyʳ optimized
rack-mountable barebone system. The GN70-B7056 is designed to support
dual
Intel
®
Xeon Processor E5-2600 Series Processors and up to 128GB UDIMM /
256GB RDIMM / 512GB LRDIMM
of DDR3 memory, providing a rich feature set and incredible performance. Leveraging advanced technology from Intel®, the GN70-B7056 server system is capable of offering scalable 32 and 64-bit computing, high bandwidth memory design, and lightning-fast PCI-E bus implementation. The GN70-B7056 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage.
TYAN
®
also offers the GN70-B7056 in a version that can support up to eight 3.5” or
2.5” hot-swap hard drives. The GN70-B7056 uses TYAN’s latest chassis featuring a robust structure and a solid mechanical enclosure. All of this provides GN70-B7056 the power and flexibility to meet the needs of nowadays server application.
1.2 Product Models
Model HDD Bays Power supply
B7056G70W8HR-2T Hot-swap, 8HDDs (1+1) 770W
B7056G70W8HR Hot-swap, 8HDDs (1+1) 770W
B7056G70V8HR Hot-swap, 8HDDs (1+1) 770W
http://www.tyan.com
16
1.3 Features
TYAN GN70-B7056 (B7056G70V8HR) ʳ
Form Factor 2U Rackmount
Gross Weight 25 kg
Chassis Model GN70
Dimension (D x W x H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard S7056GM3NR
System
Board Dimension EATX, 12"x13" (305x330mm)
Buttons (1) RST / (1) ID / (1) PWR w/ LED
LEDs (1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports (2) USB ports
Type / Q'ty 2.5" or 3.5" Hot-Swap / (8)
External Drive Bay
HDD backplane support
SAS / SATA 6.0Gb/s
System Cooling Configuration
FAN (4) 6cm fans
Type ERP1U
Efficiency PFC / 80 plus gold
Redundancy 1+1
Serviceability Hot-swap
Input Range Full-range AC(100-240V)
Frequency 50/60 Hertz
Power Supply
Output Watts 770 Watts
Supported CPU Series
Intel Xeon Processor E5-2600 Series
Socket Type / Q'ty LGA2011 / (2)
Thermal Design Power (TDP) wattage
Max up to 130W
Processor
System Bus
Up to 8.0/ 7.2/ 6.4 GT/s with Intel QuickPath Interconnect (QPI) support
PCH Intel C602
Chipset
Super I/O Nuvoton 83773G
Supported DIMM Qty
(8)+(8) DIMM slots
DIMM Type / Speed
DDR3/DDR3L 800 / 1066 / 1333 / 1600 RDIMM, 800 / 1066 / 1333 UDIMM / LRDIMM
Capacity
up to 128GB UDIMM / 256GB RDIMM / 512GB LRDIMM
Memory channel
4 Channels per CPU / Support 2 R/LR-DIMMs or 2 UDIMMs per channel
Memory
Memory voltage 1.5V or 1.35V
http://www.tyan.com
17
PCI-E
(2) sets of the following expansion combination: / (1) PCI-E x16 slot (w/x16 or x8 link) + (1) PCI-E x8 slot (w/x0 or x8 link) + (1) PCI-E x8 slot
Expansion Slots
Recommended TYAN Riser Card
M7056-L24-3F, PCI-E x16 2U riser card (left) / M7056-R24-3F, PCI-E x16 2U riser card (right)
Port Q'ty (3) GbE ports
LAN
Controller Intel 82574L / Intel I350-BT2
Connector type D-Sub 15-pin
Resolution Up to 1920x1024
Graphic
Chipset Aspeed AST2300
USB (4) ports (2 at front, 2 at rear)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O Ports
RJ-45 (3) ports
Chipset Nuvoton 83773G
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature Monitors temperature for CPU & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
System Monitoring
Others Chassis intrusion detection / Watchdog timer support
Onboard Chipset Onboard Aspeed AST2300
AST2300 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / USB 2.0 virtual hub
Server Management
AST2300 iKVM Feature
24-bit high quality video compression / 10/100 Mb/s MAC interface
Brand / ROM size AMI / 8MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0 /SMBIOS2.3
/
PXE boot / ACPI 2.0 power management /Power on mode after power recovery / User-configurable H/W monitoring / Auto-configurable of hard disk types
Operating System
OS supported list Please visit our web site for the latest update.
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating Environment
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS RoHS 6/6 Compliant Yes
http://www.tyan.com
18
Barebone (1) GN70B7056 Barebone
Heatsink / Cooler (2) LGA2011 CPU heatsinks
Rail kit (1) sliding rail kit
Manual (1) MB User's manual + (1) BB User's manual
Installation CD (1) TYAN installation CD
Package Contains
Cable Power Cord
(2) CCBL-0317, US type power cord / (2) CCBL-0300, EU type power cord
ʳ
TYAN GN70-B7056 (B7056G70W8HR)
ʳ
Form Factor 2U Rackmount
Gross Weight 25 kg
Chassis Model GN70
Dimension (D x W x H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard S7056WGM3NR
System
Board Dimension EATX, 12"x13" (305x330mm)
Buttons (1) RST / (1) ID / (1) PWR w/ LED
LEDs (1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports (2) USB ports
Type / Q'ty 2.5" or 3.5" Hot-Swap / (8)
External Drive Bay
HDD backplane support
SAS / SATA 6.0Gb/s
System Cooling Configuration
FAN (4) 6cm fans
Type ERP1U
Efficiency PFC / 80 plus gold
Redundancy 1+1
Serviceability Hot-swap
Input Range Full-range AC(100-240V)
Frequency 50/60 Hertz
Power Supply
Output Watts 770 Watts
Supported CPU Series
Intel Xeon Processor E5-2600 Series
Socket Type / Q'ty LGA2011 / (2)
Thermal Design Power (TDP) wattage
Max up to 130W
Processor
System Bus
Up to 8.0/ 7.2/ 6.4 GT/s with Intel QuickPath Interconnect (QPI) support
PCH Intel C602 with TRK-5 upgrade ROM module
Chipset
Super I/O Nuvoton 83773G
http://www.tyan.com
19
Supported DIMM Qty
(8)+(8) DIMM slots
DIMM Type / Speed
DDR3/DDR3L 800 / 1066 / 1333 / 1600 RDIMM, 800 / 1066 / 1333 UDIMM / LRDIMM
Capacity
up to 128GB UDIMM / 256GB RDIMM / 512GB LRDIMM
Memory channel
4 Channels per CPU / Support 2 R/LR-DIMMs or 2 UDIMMs per channel
Memory
Memory voltage 1.5V or 1.35V
PCI-E
(2) sets of the following expansion combination: / (1) PCI-E x16 slot (w/x16 or x8 link) + (1) PCI-E x8 slot (w/x0 or x8 link) + (1) PCI-E x8 slot
Expansion Slots
Recommended TYAN Riser Card
M7056-L24-3F, PCI-E x16 2U riser card (left) / M7056-R24-3F, PCI-E x16 2U riser card (right)
Port Q'ty (3) GbE ports
LAN
Controller Intel 82574L / Intel I350-BT2
Connector type D-Sub 15-pin
Resolution Up to 1920x1024
Graphic
Chipset Aspeed AST2300
USB (4) ports (2 at front, 2 at rear)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O Ports
RJ-45 (3) ports
Chipset Nuvoton 83773G
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature Monitors temperature for CPU & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
System Monitoring
Others Chassis intrusion detection / Watchdog timer support
Onboard Chipset Onboard Aspeed AST2300
AST2300 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / USB 2.0 virtual hub
Server Management
AST2300 iKVM Feature
24-bit high quality video compression / 10/100 Mb/s MAC interface
Brand / ROM size AMI / 8MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0 /SMBIOS2.3
/
PXE boot / ACPI 2.0 power management /Power on mode after power recovery / User-configurable H/W monitoring / Auto-configurable of hard disk types
Operating System
OS supported list Please visit our web site for the latest update.
http://www.tyan.com
20
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating Environment
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS RoHS 6/6 Compliant Yes
Barebone (1) GN70B7056 Barebone
Heatsink / Cooler (2) LGA2011 CPU heatsinks
Rail kit (1) sliding rail kit
Manual (1) MB User's manual + (1) BB User's manual
Installation CD (1) TYAN installation CD
Package Contains
Cable Power Cord
(2) CCBL-0317, US type power cord / (2) CCBL-0300, EU type power cord
ʳ
TYAN GN70-B7056 (B7056G70W8HR-2T)
ʳ
Form Factor 2U Rackmount
Gross Weight 25 kg
Chassis Model GN70
Dimension (D x W x H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard S7056WGM3NR-2T
System
Board Dimension EATX, 12"x13" (305x330mm)
Buttons (1) RST / (1) ID / (1) PWR w/ LED
LEDs (1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports (2) USB ports
Type / Q'ty 2.5" or 3.5" Hot-Swap / (8)
External Drive Bay
HDD backplane support
SAS / SATA 6.0Gb/s
System Cooling Configuration
FAN (4) 6cm fans
Type ERP1U
Efficiency PFC / 80 plus gold
Redundancy 1+1
Serviceability Hot-swap
Input Range Full-range AC(100-240V)
Frequency 50/60 Hertz
Power Supply
Output Watts 770 Watts
http://www.tyan.com
21
Supported CPU Series
Intel Xeon Processor E5-2600 Series
Socket Type / Q'ty LGA2011 / (2)
Thermal Design Power (TDP) wattage
Max up to 130W
Processor
System Bus
Up to 8.0/ 7.2/ 6.4 GT/s with Intel QuickPath Interconnect (QPI) support
PCH Intel C602 with TRK-5 upgrade ROM module
Chipset
Super I/O Nuvoton 83773G
Supported DIMM Qty
(8)+(8) DIMM slots
DIMM Type / Speed
DDR3/DDR3L 800 / 1066 / 1333 / 1600 RDIMM, 800 / 1066 / 1333 UDIMM / LRDIMM
Capacity
up to 128GB UDIMM / 256GB RDIMM / 512GB LRDIMM
Memory channel
4 Channels per CPU / Support 2 R/LR-DIMMs or 2 UDIMMs per channel
Memory
Memory voltage 1.5V or 1.35V
PCI-E
(2) sets of the following expansion combination: / (1) PCI-E x16 slot (w/x16 or x8 link) + (1) PCI-E x8 slot (w/x0 or x8 link) + (1) PCI-E x8 slot
Expansion Slots
Recommended TYAN Riser Card
M7056-L24-3F, PCI-E x16 2U riser card (left) / M7056-R24-3F, PCI-E x16 2U riser card (right)
Port Q'ty (1) GbE port, (2) 10 GbE ports
LAN
Controller Intel 82574L / Intel X540-AT2
Connector type D-Sub 15-pin
Resolution Up to 1920x1024
Graphic
Chipset Aspeed AST2300
USB (4) ports (2 at front, 2 at rear)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O Ports
RJ-45 (3) ports
Chipset Nuvoton 83773G
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature
Monitors temperature for CPU & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
System Monitoring
Others
Chassis intrusion detection / Watchdog timer support
http://www.tyan.com
22
Onboard Chipset Onboard Aspeed AST2300
AST2300 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / USB 2.0 virtual hub
Server Management
AST2300 iKVM Feature
24-bit high quality video compression / 10/100 Mb/s MAC interface
Brand / ROM size AMI / 8MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0 /SMBIOS2.3 /PXE boot / ACPI 2.0 power management /Power on mode after power recovery / User-configurable H/W monitoring / Auto-configurable of hard disk types
Operating System
OS supported list Please visit our web site for the latest update.
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating Environment
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS RoHS 6/6 Compliant Yes
Barebone (1) GN70B7056 Barebone
Heatsink / Cooler (2) LGA2011 CPU heatsinks
Rail kit (1) sliding rail kit
Manual (1) MB User's manual + (1) BB User's manual
Installation CD (1) TYAN installation CD
Package Contains
Cable Power Cord
(2) CCBL-0317, US type power cord / (2) CCBL-0300, EU type power cord
ʳ
http://www.tyan.com
23
1.4 Standard Parts List
This section describes GN70-B7056 package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. The product should arrive packaged as illustrated below.
1.4.1 Box Contents
Component Description
2U chassis, (8) hot swap HDD bays
TYAN
®
S7056 system board
(pre-installed)
(2) ERP1U 770W power supply unit
(4) System fan
M1601T70-D-PDB Power Distribution
Board (pre-installed)
M1245G70-BP6-8 SATA/SAS HDD
Backplane Board (pre-installed)
M1709G70-FPB (pre-installed)
M7056-L24-3F riser card (pre-installed)
M7056-R24-3F riser card (pre-installed)
M1806G70-FB (pre-installed)
http://www.tyan.com
24
1.4.2 Accessories
If any items are missing or appear damaged, contact your retailer or browse to TYAN
®
’s website for service:
http://www.tyan.com
The web site also provides information of other TYAN® products, as well as FAQs, compatibility lists, BIOS settings, etc.
TYAN® Motherboard
Drive CD
Heatsink x 2
Screw Pack x 3 Rail Kit
DVD Bracket Kit DVD Cable Kit
AC Power Cord 125V
(US) x 2
AC Power Cord 250V
(Europe) x 2
http://www.tyan.com
25
Barebone Manual Mainboard Manual
Addendum for China
Use Only
http://www.tyan.com
26
1.5 About the Product
The following views show you the product.
1.5.1 System Front View
1 Ears
2 3.5” /2.5” HDD bays
3 USB Ports
4 ID Button
5 NMI Button
6 RESET Button
7 LAN1/LAN2/LAN3
8 ID LED
9 System Fan Fail LED
10 System Warning LED
11 Power On/OFF Button with LED
http://www.tyan.com
27
LED Definitions
LED Status
LED Color
Behavior Remark
Power on Solid on
Power LED
Power off
Green
Off
Normal Off System Warning LED
Warning
Amber
Solid on
All BMC warning PSU alert, PSU fail
Normal Off System Fan
Fail
System Fan Fail
Red
Solid on
System Fan fail warning
Normal Off ID LED
Located
Blue
Solid on
Local and remote
Off line Off
Link Solid on
LAN1 LAN2 LAN3
Activity
Green
Blinking
PSU Redundancy 1+1 System Warning LED Indication
Status System Warning LED
2 PSU and 2 PSU AC cords are connected.
Off
1 PSU and 1 PSU AC cord are connected.
Amber solid on
2 PSU and 2 PSU AC cords are connected. After system is powered on, disconnect 1 PSU AC cord.
Amber solid on
2 PSU and 2 PSU AC cords are connected. After system is powered on, disconnect 1 PSU.
Amber solid on
http://www.tyan.com
28
HDD LED
HDD Status Status LED
Color: Amber
Activity LED Color: Green
No Driver Present or power disconnected OFF OFF
No Activity OFF Solid ONDriver Present
Access Activity OFF Blinking HDD Fail Solid ON OFF Rebuild Blinking @4Hz OFF Identify (Locate the HDD) Blinking @1Hz OFF