TYAN B8236G70W8HR-HE-IL, B8236G70W8HR-HE-IL-N229, B8236G70W8HR-HE-IL-N2275, GN70-B8236-IL Service Manual

Welcome to the Iceberg
Altus 2850GTi
Manual
1
GN70-B8236-IL
Service Engineer’s Manual
2
3
PREFACE
Copyright
This publication, including all photographs, illustrations, and software, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of manufacturer.
Copyright 2011 MiTAC International Corporation. All rights reserved. TYAN® is a registered trademark of MiTAC International Corporation.
Version 1.0
Disclaimer
Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and reliability prior to printing. MiTAC assumes no liability whatsoever, and disclaims any express or implied
warranty, relating to sale and/or use of TYAN
®
products including liability or warranties relating to fitness for a particular purpose or merchantability. MiTAC retains the right to make changes to produce descriptions and/or specifications at any time, without notice. In no event will MiTAC be held liable for any direct or indirect, incidental or consequential damage, loss of use, loss of data or other malady resulting from errors or inaccuracies of information contained in this document.
Trademark Recognition
All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including, but not limited to the following.
TYAN® is a trademark of MiTAC International Corporation. Intel
®
is a trademark of Intel® Corporation.
AMI
®
, AMIBIOS® and combinations thereof are trademarks of AMI Technologies. Microsoft®, Windows® are trademarks of Microsoft Corporation. IBM
®
, PC®, AT® and PS/2® are trademarks of IBM Corporation. Winbond
®
is a trademark of Winbond Electronics Corporation.
4
FCC Declaration
Notice for the USA
Compliance Information Statement (Declaration of Conformity Procedure) DoC FCC Part 15: This device complies with part 15 of the FCC Rules
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:
This device must not cause harmful interference.  This device must accept any interference received, including
interference that may cause undesirable operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Notice for Canada
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.
Notice for Europe (CE Mark)
This product is in conformity with the Council Directive 2004/108/EC.
CAUTION: Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. There will be danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer. Dispose of used battery according to manufacturer instructions and in accordance with your local regulations.
5
About this Manual
This manual provides you with instructions on installing your TYAN GN70-B8236-IL. This Manual is intended for experienced users and integrators with hardware knowledge of personal computers.
This manual consists of the following parts:
Chapter1:
Provides an introduction to the TYAN GN70-B8236-IL barebones, standard parts list, describes the external components, gives a table of key components, and provides block diagram of the system.
Chapter2:
Covers procedures on installing the CPU, memory modules and hard drives.
Chapter3:
Covers removal and replacement procedures for pre-installed components.
Appendix:
List the cable connection and FRU part tables for reference of system setup, and technical support in case a problem arises with your system.
6
Safety and Compliance Information
Before installing and using TYAN GN70-B8236-IL, take note of the following precautions:
·Read all instructions carefully.
·Do not place the unit on an unstable surface, cart, or stand.
·Do not block the slots and opening on the unit, which are provided for
ventilation.
·Only use the power source indicated on the marking label. If you are not sure, contact the power company.
·The unit uses a three-wire ground cable, which is equipped with a third pin to ground the unit and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not support this kind of plug, contact your electrician to replace your obsolete outlet.
·Do not place anything on the power cord. Place the power cord where it will not be in the way of foot traffic.
·Follow all warnings and cautions in this manual and on the unit case.
·Do not push objects in the ventilation slots as they may touch high voltage
components and result in shock and damage to the components.
· When replacing parts, ensure that you use parts specified by the
manufacturer.
·When service or repairs have been done, perform routine safety checks to verify that the system is operating correctly.
·Avoid using the system near water, in direct sunlight, or near a heating device.
·Cover the unit when not in use.
7
Safety Information
Retain and follow all product safety and operating instructions provided with your equipment. In the event of a conflict between the instructions in this guide and the instructions in equipment documentation, follow the guidelines in the equipment documentation.
Observe all warnings on the product and in the operating instructions. To reduce the risk of bodily injury, electric shock, fire and damage to the equipment, observe all precautions included in this guide.
You must become familiar with the safety information in this guide before you install, operate, or service TYAN products.
Symbols on Equipment
Caution. This symbol indicates a potential
hazard. The potential for injury exists if cautions are not observed. Consult equipment documentation for specific details.
Warning. This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.
Warning. This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.
To reduce risk of injury from a hot component, allow the surface to cool before touching.
General Precautions
· Follow all caution and warning instructions marked on the equipment and explained in the accompanying equipment documentation.
Machine Room Environment
 · Make sure that the area in which you install the system is properly
ventilated and climate-controlled.
8
· Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the electrical rating label of the equipment.
· Do not install the system in or near a plenum, air duct, radiator, or heat register.
· Never use the product in a wet location.
Equipment Chassis
· Do not block or cover the openings to the system.
· Never push objects of any kind through openings in the equipment.
Dangerous voltages might be present.
· Conductive foreign objects can produce a short circuit and cause fire, electric shock, or damage to your equipment.
· Lift equipment using both hands and with your knees bent.
Equipment Racks
To avoid injury or damage to the equipment:
· Observe local occupational health and safety requirements and guidelines for manual materials handling.
· Do not attempt to move a rack by yourself; a minimum of two people are needed to move a rack.
· Do not attempt to move a fully loaded rack. Remove equipment from the rack before moving it.
· Do not attempt to move a rack on an incline that is greater than 10 degrees from the horizontal.
· Make sure the rack is properly secured to the floor or ceiling.
· Make sure the stabilizing feet are attached to the rack if it is a single-rack
installation.
· Make sure racks are coupled together if it is a multiple-rack installation.
· Make sure the rack is level and stable before installing an appliance in the
rack.
· Make sure the leveling jacks are extended to the floor.
9
· Make sure the full weight of the rack rests on the leveling jacks.
· Always load the rack from the bottom up. Load the heaviest component in
the rack first.
· Make sure the rack is level and stable before pulling a component out of the rack.
· Make sure only one component is extended at a time. A rack might become unstable if more than one component is extended.
To avoid damage to the equipment:
· The rack width and depth must allow for proper serviceability and cable management.
· Ensure that there is adequate airflow in the rack. Improper installation or restricted airflow can damage the equipment.
· The rack cannot have solid or restricted airflow doors. You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system.
· If you install the Model in a rack, do not place equipment on top of the unit. It will cause restricted airflow and might cause damage to the equipment.
·
Make sure the product is properly matted with the rails. Products that are
improperly matted with the rails might be unstable.
·
Verify that the AC power supply branch circuit that provides power to the
rack is not overloaded. This will reduce the risk of personal injury, fire, or damage to the equipment. The total rack load should not exceed 80 percent of the branch circuit rating. Consult the electrical authority having jurisdiction over your facility wiring and installation requirements.
Equipment Power Cords
· Use only the power cords and power supply units provided with your system. The system might have one or more power cords.
· Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
· In all European electrical environments, you must ground the Green/Yellow tab on the power cord. If you do not ground the Green/Yellow tab, it can cause an electrical shock due to high leakage currents.
·
Do not place objects on AC power cords or cables. Arrange them so that no
10
one might accidentally step on or trip over them.
· Do not pull on a cord or cable. When unplugging from the electrical outlet, grasp the cord by the plug.
· To reduce the risk of electrical shock, disconnect all power cords before servicing the appliance.
Equipment Batteries
· The system battery contains lithium manganese dioxide. If the battery pack is not handled properly, there is risk of fire and burns.
· Do not disassemble, crush, puncture, short external contacts, or dispose of the battery in fire or water.
· Do not expose the battery to temperatures higher than 60°C (140°F).
· The system battery is not replaceable. If the battery is replaced by an
incorrect type, there is danger of explosion. Replace the battery only with a spare designated for your product.
· Do not attempt to recharge the battery.
· Dispose of used batteries according to the instructions of the manufacturer.
Do not dispose of batteries with the general household waste. To forward them to recycling or proper disposal, use the public
collection system or return them to TYAN, your authorized TYAN partner, or their agents.
Equipment Modifications
· Do not make mechanical modifications to the system. TYAN is not responsible for the regulatory compliance of TYAN equipment that has been modified.
Equipment Repairs and Servicing
· The installation of internal options and routine maintenance and service of this product should be performed by individuals who are knowledgeable about the procedures, precautions, and hazards associated with equipment containing hazardous energy levels.
· Do not exceed the level of repair specified in the procedures in the product documentation. Improper repairs can create a safety hazard.
11
· Allow the product to cool before removing covers and touching internal components.
· Remove all watches, rings, or loose jewelry when working before removing covers and touching internal components.
· Do not use conductive tools that could bridge live parts.
· Use gloves when you remove or replace system components; they can
become hot to the touch.
· If the product sustains damage requiring service, disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider. Examples of damage requiring service include:
– The power cord, extension cord, or plug has been damaged. – Liquid has been spilled on the product or an object has fallen into the
product. – The product has been exposed to rain or water. – The product has been dropped or damaged. – The product does not operate normally when you follow the operating
instructions.
12
13
Table of Contents
Chapter 1: Overview....................................................................... 15
1.1 About the TYAN GN70-B8236-IL ........................................... 15
1.2 Product Models....................................................................... 15
1.3 Features ............................................................................ 16
1.4 Standard Parts List ................................................................. 23
1.4.1 Box Contents ................................................................... 23
1.4.2 Accessories ..................................................................... 24
1.5 About the Product................................................................... 26
1.5.1 System Front View .......................................................... 26
1.5.2 System Rear View ........................................................... 29
1.5.3 Motherboard (S8236-IL) Layout ...................................... 30
1.5.4 Jumpers & Connectors .................................................... 31
1.5.5 System Block Diagram (S8236-IL) .................................. 32
1.5.6 Internal View.................................................................... 33
Chapter 2: Setting Up..................................................................... 35
2.0.1 Before you Begin ............................................................. 35
2.0.2 Work Area........................................................................ 35
2.0.3 Tools ................................................................................ 35
2.0.4 Precautions...................................................................... 36
2.1 Installing Motherboard Components ...................................... 37
2.1.1 Removing the Chassis Cover.......................................... 37
2.1.2 Removing the Riser Card Brackets ................................. 39
2.1.3 Installing the CPU and Heatsink...................................... 40
2.1.4 Installing the Memory ...................................................... 43
2.1.4 Installing Hard Drives ...................................................... 48
2.1.5 Installing the PCI-E Cards ............................................... 51
2.2 Rack Mounting........................................................................ 52
2.2.1 Installing the Server in a Rack......................................... 52
2.2.2 Removing the Server from a Rack ............................... 56
Chapter 3: Replacing Pre-Installed Components ........................ 57
3.1 Introduction............................................................................. 57
3.2 Disassembly Flowchart........................................................... 57
3.3 Removing the Cover............................................................... 58
3.4 Replacing Motherboard Components..................................... 58
3.4.1 Replacing PCI-E Riser Card Cards ................................. 58
3.4.2 Disconnecting All Motherboard Cables ........................... 60
3.4.3 Removing the Motherboard ............................................. 61
3.5 Replacing the Power Distribution Board................................. 62
3.6 Replacing the Front Panel Board ........................................... 63
14
3.6.1 Front Panel Board Specifications .................................... 65
3.6.2 FPB LED and Connector Pin Definition........................... 66
3.7 Replacing the System Fan ..................................................... 68
3.8 Replacing the Fan Backplane Board...................................... 70
3.8.1 Fan BP Board Specifications........................................... 73
3.8.2 Fan BP Board LED Definitions ........................................ 73
3.9 Replacing the HDD Backplane Board .................................... 74
3.9.1 HDD BP Board Specifications ......................................... 75
3.9.2 HDD BP Board LED Definitions ...................................... 76
Appendix I: Cable Connection Tables.......................................... 79
Appendix II: FRU Parts Table ........................................................ 81
Appendix III: Fan and Temp Sensors ........................................... 83
Appendix IV: Technical Support ................................................... 87
15
Chapter 1: Overview
1.1 About the TYAN GN70-B8236-IL
Congratulations on your purchase of the TYAN
®
GN70-B8236-IL, a highly optimized rack-mountable barebone system. The GN70-B8236-IL is designed to support dual
AMD
®
32nm 8-Core/12-Core/16-Core Opteron
TM
6200 Series (Interlagos) Processors and up to 256GB RDIMM and 64GB UDIMM of DDR3 memory,
providing a rich feature set and incredible performance. Leveraging advanced technology from AMD
®
, the GN70-B8236-IL server system is capable of offering scalable 32 and 64-bit computing, high bandwidth memory design, and lightning-fast PCI-E bus implementation. The GN70-B8236-IL not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage.
TYAN
®
also offers the GN70-B8236-IL in a version that can support up to eight 3.5” or 2.5” hot-swap hard drives. The GN70-B8236-IL uses TYAN’s latest chassis featuring a robust structure and a solid mechanical enclosure. All of this provides GN70-B8236-IL the power and flexibility to meet the needs of nowadays server application.
1.2 Product Models
Model HDD Bays Power supply
B8236G70W8HR-HE-IL Hot-swap, 8HDDs (1+1) redundant 770W
B8236G70W8HR-HE-IL-N229 Hot-swap, 8HDDs (1+1) redundant 770W
B8236G70W8HR-HE-IL-N2275 Hot-swap, 8HDDs (1+1) redundant 770W
16
1.3 Features
TYAN GN70B8236-IL (B8236G70W8HR-HE-IL)
Form Factor 2U Rackmount
Gross Weight 25 kg
Chassis Model GN70
Dimension (D x W x H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard S8236WGM3NR-HE-IL
System
Board Dimension EEB, 12"x13" (305x330mm)
Buttons (1) RST / (1) ID / (1) PWR w/ LED
LEDs (1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports (2) USB ports
Type / Q'ty 2.5" or 3.5" Hot-Swap / (8)
External Drive Bay
Supported HDD Interface
SATA-II 3.0Gb/s / SAS 6.0Gb/s
System Cooling Configuration
FAN (8) 6cm fans
Type RPS1U
Efficiency PFC / 80 plus gold
Redundancy 1+1
Input Range Full-range AC(100-240V)
Frequency 60 Hertz
Power Supply
Output Watts 770 Watts
Supported CPU Series
AMD 45nm 8-Core/12-Core Opteron 6100 Series Processors (Magny-Cours), AMD 32nm 8-Core /12-Core/16-Core Opteron 6200 Series Processors (Interlagos)
Socket Type / Q'ty G34 / (2)
Thermal Design Power (TDP)
115W
Processor
System Bus Up to 6.4 GT/s Hyper-Transport link support
Chipset AMD SR5690 + SR5650 + SP5100
Chipset
Super I/O Winbond W83627DHG-P
Supported DIMM Qty
(16) DIMM slots
DIMM Type / Speed
U/RDDR3, LV and ULV DDR3, LRDIMM modules / Design spec compliant with 1866/ 1600/ 1333/ 1066/ 800 MHz
Capacity Up to 256GB RDIMM/ 64GB UDIMM
Memory channel 4 Channels per CPU
Memory
Memory voltage 1.5V/1.35V/1.25V
17
PCI-E (3) PCI-E Gen.2 x16 slots
Max. HBA Dimension (H x L)
(6) 111.15mm x 312.00mm (FH/FL)
Expansion Slots
Pre-install TYAN Riser Card
M2201-L16-2F, PCI-E x16 2U riser card (left) / (2) M2202-R16-2F, PCI-E x16 2U riser card (right)
Port Q'ty (3)
LAN
Controller Intel 82574L / Intel 82576EB
Connector type D-Sub 15-pin
Resolution Up to 1600x1200@60Hz
Graphic
Chipset Aspeed AST2050
USB (4) ports (2 at front, 2 at rear)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O Ports
RJ-45 (3) ports
Chipset Winbond W83795G
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature Monitors temperature for CPU & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
System Monitoring
Others Chassis intrusion detection / Watchdog timer support
Onboard Chipset Onboard Aspeed AST2050
AST2050 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / BIOS update
Server Management
AST2050 iKVM Feature
24-bit high quality video compression / Dual 10/100 Mb/s MAC interfaces
Brand / ROM size AMI / 4MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0 /SMBIOS2.3 /PXE boot / ACPI 2.0 power management /Power on mode after power recovery / User-configurable H/W monitoring / Auto-configurable of hard disk types
Operating System
OS supported list Please visit our Web site for the latest update.
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating Environment
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6 Compliant
Yes
18
Barebone (1) GN70B8236-IL Barebone
Heatsink / Cooler (2) G34 CPU heatsinks
Rail kit (1) CRAL-0031, sliding rail kit for KGT24/ KGT62
Mounting Ear (1) mounting ear kit
Manual (1) MB User's manual + (1) BB User's manual
Installation CD (1) TYAN installation CD
Package Contains
Cable
Power Cord
(2) CCBL-0310, US type power cord / (2) CCBL-0300, EU type power cord
Optional accessories
Peripheral (1) CSTK-0080, Slim type DVD kit w/cables
TYAN GN70B8236-IL (B8236G70W8HR-HE-IL-N229)
Form Factor 2U Rackmount
Gross Weight 25 kg
Chassis Model GN70
Dimension (D x W x H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard S8236WGM3NR-HE-IL
System
Board Dimension EEB, 12"x13" (305x330mm)
Buttons (1) RST / (1) ID / (1) PWR w/ LED
LEDs (1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports (2) USB ports
Type / Q'ty 2.5" or 3.5" Hot-Swap / (8)
External Drive Bay
Supported HDD Interface
SATA-II 3.0Gb/s / SAS 6.0Gb/s
System Cooling Configuration
FAN (8) 6cm fans
Type EPS1U
Efficiency PFC / 80 plus gold
Redundancy 1+1
Input Range Full-range AC(100-240V)
Frequency 60 Hertz
Power Supply
Output Watts 770 Watts
Supported CPU Series
AMD 45nm 8-Core/12-Core Opteron 6100 Series Processors (Magny-Cours), AMD 32nm 8-Core /12-Core/16-Core Opteron 6200 Series Processors (Interlagos)
Socket Type / Q'ty G34 / (2)
Thermal Design Power (TDP)
115W
Processor
System Bus Up to 6.4 GT/s Hyper-Transport link support
19
Chipset AMD SR5690 + SR5650 + SP5100
Chipset
Super I/O Winbond W83627DHG-P
Supported DIMM Qty
(16) DIMM slots
DIMM Type / Speed
U/RDDR3, LV and ULV DDR3, LRDIMM modules / Design spec compliant with 1866/ 1600/ 1333/ 1066/ 800 MHz
Capacity Up to 256GB RDIMM/ 64GB UDIMM
Memory channel 4 Channels per CPU
Memory
Memory voltage 1.5V/1.35V/1.25V
PCI-E (3) PCI-E Gen.2 x16 slots
Max. HBA Dimension (H x L)
(6) 111.15mm x 312.00mm (FH/FL)
Expansion Slots
Pre-install TYAN Riser Card
M2201-L16-2F, PCI-E x16 2U riser card (left) / (2) M2202-R16-2F, PCI-E x16 2U riser card (right)
Port Q'ty (3)
LAN
Controller Intel 82574L / Intel 82576EB
Connector type D-Sub 15-pin
Resolution Up to 1600x1200@60Hz
Graphic
Chipset Aspeed AST2050
USB (4) ports (2 at front, 2 at rear)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O Ports
RJ-45 (3) ports
Chipset Winbond W83795G
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature Monitors temperature for CPU & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
System Monitoring
Others Chassis intrusion detection / Watchdog timer support
Onboard Chipset Onboard Aspeed AST2050
AST2050 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / BIOS update
Server Management
AST2050 iKVM Feature
24-bit high quality video compression / Dual 10/100 Mb/s MAC interfaces
Brand / ROM size AMI / 4MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0 /SMBIOS2.3 /PXE boot / ACPI 2.0 power management /Power on mode after power recovery / User-configurable H/W monitoring / Auto-configurable of hard disk types
Operating System
OS supported list Please visit our Web site for the latest update.
20
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating Environment
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6 Compliant
Yes
Barebone (1) GN70B8236-IL Barebone w/(2) NV M2090 cards
Heatsink / Cooler (2) G34 CPU heatsinks
Rail kit (1) CRAL-0031, sliding rail kit for KGT24/ KGT62
Mounting Ear (1) mounting ear kit
Manual (1) MB User's manual + (1) BB User's manual
Installation CD (1) TYAN installation CD
Package Contains
Cable
Power Cord
(2) CCBL-0310, US type power cord / (2) CCBL-0300, EU type power cord
Optional accessories
Peripheral (1) CSTK-0080, Slim type DVD kit w/cables
TYAN GN70B8236-IL (B8236G70W8HR-HE-IL-N2275)
Form Factor 2U Rackmount
Gross Weight 25 kg
Chassis Model GN70
Dimension (D x W x H)
27.56" x 17.72" x 3.43" (700 x 450 x 87mm)
Motherboard S8236WGM3NR-HE-IL
System
Board Dimension EEB, 12"x13" (305x330mm)
Buttons (1) RST / (1) ID / (1) PWR w/ LED
LEDs (1) PWR / (1) ID / (1) Warning / (3) LAN
Front Panel
I/O Ports (2) USB ports
Type / Q'ty 2.5" or 3.5" Hot-Swap / (8)
External Drive Bay
Supported HDD Interface
SATA-II 3.0Gb/s / SAS 6.0Gb/s
System Cooling Configuration
FAN (8) 6cm fans
Type EPS1U
Efficiency PFC / 80 plus gold
Redundancy 1+1
Input Range Full-range AC(100-240V)
Frequency 60 Hertz
Power Supply
Output Watts 770 Watts
21
Supported CPU Series
AMD 45nm 8-Core/12-Core Opteron 6100 Series Processors (Magny-Cours), AMD 32nm 8-Core /12-Core/16-Core Opteron 6200 Series Processors (Interlagos)
Socket Type / Q'ty G34 / (2)
Thermal Design Power (TDP)
115W
Processor
System Bus Up to 6.4 GT/s Hyper-Transport link support
Chipset AMD SR5690 + SR5650 + SP5100
Chipset
Super I/O Winbond W83627DHG-P
Supported DIMM Qty
(16) DIMM slots
DIMM Type / Speed
U/RDDR3, LV and ULV DDR3, LRDIMM modules / Design spec compliant with 1866/ 1600/ 1333/ 1066/ 800 MHz
Capacity Up to 256GB RDIMM/ 64GB UDIMM
Memory channel 4 Channels per CPU
Memory
Memory voltage 1.5V/1.35V/1.25V
PCI-E (3) PCI-E Gen.2 x16 slots
Max. HBA Dimension (H x L)
(6) 111.15mm x 312.00mm (FH/FL)
Expansion Slots
Pre-install TYAN Riser Card
M2201-L16-2F, PCI-E x16 2U riser card (left) / (2) M2202-R16-2F, PCI-E x16 2U riser card (right)
Port Q'ty (3)
LAN
Controller Intel 82574L / Intel 82576EB
Connector type D-Sub 15-pin
Resolution Up to 1600x1200@60Hz
Graphic
Chipset Aspeed AST2050
USB (4) ports (2 at front, 2 at rear)
COM (1) DB-9 COM port
VGA (1) D-Sub 15-pin port
I/O Ports
RJ-45 (3) ports
Chipset Winbond W83795G
Voltage
Monitors voltage for CPU, memory, chipset & power supply
Temperature Monitors temperature for CPU & system environment
LED
Over temperature warning indicator / Fan & PSU fail LED indicator
System Monitoring
Others Chassis intrusion detection / Watchdog timer support
22
Onboard Chipset Onboard Aspeed AST2050
AST2050 IPMI Feature
IPMI 2.0 compliant baseboard management controller (BMC) / Supports storage over IP and remote platform-flash / BIOS update
Server Management
AST2050 iKVM Feature
24-bit high quality video compression / Dual 10/100 Mb/s MAC interfaces
Brand / ROM size AMI / 4MB
BIOS
Feature
Plug and Play (PnP) /PCI2.3 /WfM2.0 /SMBIOS2.3 /PXE boot / ACPI 2.0 power management /Power on mode after power recovery / User-configurable H/W monitoring / Auto-configurable of hard disk types
Operating System
OS supported list Please visit our Web site for the latest update.
FCC (DoC) Class A
Regulation
CE (DoC) Yes
Operating Temp. 10° C ~ 35° C (50° F~ 95° F)
Non-operating Temp.
- 40° C ~ 70° C (-40° F ~ 158° F)
Operating Environment
In/Non-operating Humidity
90%, non-condensing at 35° C
RoHS
RoHS 6/6 Compliant
Yes
Barebone (1) GN70B8236-IL Barebone w/(2) NV M2075 cards
Heatsink / Cooler (2) G34 CPU heatsinks
Rail kit (1) CRAL-0031, sliding rail kit for KGT24/ KGT62
Mounting Ear (1) mounting ear kit
Manual (1) MB User's manual + (1) BB User's manual
Installation CD (1) TYAN installation CD
Package Contains
Cable
Power Cord
(2) CCBL-0310, US type power cord / (2) CCBL-0300, EU type power cord
Optional accessories
Peripheral (1) CSTK-0080, Slim type DVD kit w/cables
23
1.4 Standard Parts List
This section describes GN70-B8236-IL package contents and accessories. Open the box carefully and ensure that all components are present and undamaged. The product should arrive packaged as illustrated below.
1.4.1 Box Contents
Component Description
2U chassis, (8) hot swap HDD bays
TYAN® S8236-IL system board (pre-installed)
(1+1) ERP1U hot-swap 770W RPSU (Delta)
(8) System fan
M1601T70-D-PDB Power Distribution Board (pre-installed)
M1245G70-BP6-STD SATA/SAS HDD Backplane Board (pre-installed)
M1709G70-FPB (pre-installed)
M2201-L16-2F riser card (pre-installed)
M2202-R8-2F riser card (pre-installed)
24
1.4.2 Accessories
If any items are missing or appear damaged, contact your retailer or browse to TYAN
®
’s website for service: http://www.tyan.com
The web site also provides information of other TYAN
®
products, as well as FAQs,
compatibility lists, BIOS settings, etc.
TYAN® Motherboard
Drive CD
Heatsink x 2
HDD Screw Pack
(12 pcs)
Rail x 2
DVD Bracket Kit DVD Cable Kit
Ventilation Bracket GPU Cable
25
SGCC Bracket_L SGCC Bracket_R
AC Power Cord 125V
(US)
AC Power Cord 250V
(Europe)
Barebone Manual Mainboard Manual
Addendum for China
Use Only
26
1.5 About the Product
The following views show you the product.
1.5.1 System Front View
1 Ears
2 3.5” HDD bays
3 USB Ports
4 ID Button
5 NMI Button
6 RESET Button
7 NIC1/NIC2/NIC3
8 ID LED
9 Warning LED
10 BMC LED (reserved)
11 Power On/OFF Button with LED