TYAN Transport GT20 B3970-U, Transport GT20, B3970-U Service Engineer's Manual

Page 1
Transport GT20
B3970-U
Service Engineer’s Manual
Page 2
Page 3
PREFACE
Copyright
This publication, including all photographs, illustrations, and soft­ware, is protected under international copyright laws, with all rights reserved. Neither this manual, nor any material contained herein, may be reproduced without written consent of the manufacturer-.
Copyright 2006
Version 1.0
Disclaimer
Information contained in this document is furnished by TYAN Com­puter Corporation and has been reviewed for accuracy and reliability prior to printing. TYAN assumes no liability whatsoever, and dis­claims any express or implied warranty, relating to sale and/or use of TYAN products including liability or warranties relating to fitness for a particular purpose or merchantability. TYAN retains the right to make changes to product descriptions and/or specifications at any time, without notice. In no event will TYAN be held liable for any direct or indirect, incidental or consequential damage, loss of use, loss of data or other malady resulting from errors or inaccuracies of information contained in this document.
Trademark Recognition
All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including, but not limited to the following.
TYAN and Transport GT20 B3970-U are trademarks of TYAN Com­puter Corporation.
Intel, Xeon, and combinations thereof are trademarks of Intel Corpo­ration.
AMD, Opteron, Athlon, and combinations thereof are trademarks of AMD Corporation.
Phoenix, PhoenixBIOS, and combinations thereof are trademarks of Phoenix Technologies.
Microsoft Windows is a trademark of Microsoft Corporation.
IBM, PC, AT, PS/2 are trademarks of IBM Corporation.
Winbond is a trademark of Winbond Electronics Corporation.
Portable Document Format (PDF) is a trademark of Adobe Corpora­tion.
Page 4
ii
Federal Communications Commission (FCC)
Notice for the USA Compliance Information State-
ment (Declaration of Conformity Procedure) DoC FCC Part 15: This device complies with part 15 of the FCC Rules
Operation is subject to the following conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received including inter­ference that may cause undesired operation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try one or more of the following measures:
– Reorient or relocate the receiving antenna. – Increase the separation between the equipment and the
receiver.
– Plug the equipment into an outlet on a circuit different from
that of the receiver.
Consult the dealer on an experienced radio/television technician for help.
Notice for Canada
This apparatus complies with the Class B limits for radio interference as specified in the Canadian Department of Communications Radio Interference Regulations. (Cet appareil est conforme aux norms de Classe B d’interference radio tel que specifie par le Ministere Cana­dien des Communications dans les reglements d’ineteference radio.)
Notice for Europe (CE Mark) This product is in conformity with the Council Directive 89/336/EEC, 92/31/EEC (EMC).
CAUTION: Lithium battery included with this board. Do not puncture, mutilate, or dispose of battery in fire. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by manufacturer. Dispose of used battery according to manufacturer instructions and in accordance with your local regulations.
Page 5
iii
About this Manual
This manual provides you with instructions on installing your Transport GT20. This manual is intended for experienced users and integrators with hardware knowledge of personal computers.
This manual consists of the following parts
Chapter 1: Provides an Introduction to the Transport GT20
B3970-U bare-bones, packing list, describes the external components, gives a table of key compo­nents, and provides block diagrams of the system.
Chapter 2: Covers procedures on installing the CPU, mem-
ory modules, an optional PCI-X card, and hard drives.
Chapter 3: Covers removal and replacement procedures for
pre-installed components
Appendix: Provides information on installing SMDC cards
and describes the differences between mainboard BIOS and system BIOS. The cable connection tables are also provided for reference of system setup .
For information on the mainboard, please refer to the attached main­board user’s manual. You can find the detailed description about jumper and BIOS settings from the motherboard manual.
Page 6
iv
SAFETY INFORMATION
Before installing and using the Transport GT20, take note of the fol­lowing precautions:
Read all instructions carefully.Do not place the unit on an unstable surface, cart, or stand.Do not block the slots and opening on the unit, which are pro-
vided for ventilation.
Only use the power source indicated on the marking label. If
you are not sure, contact the Power Company.
The unit uses a three-wire ground cable, which is equipped
with a third pin to ground the unit and prevent electric shock. Do not defeat the purpose of this pin. If your outlet does not support this kind of plug, contact your electrician to replace your obsolete outlet.
Do not place anything on the power cord. Place the power
cord where it will not be in the way of foot traffic.
Follow all warnings and cautions in this manual and on the
unit case.
Do not push objects in the ventilation slots as they may touch
high voltage components and result in shock and damage to the components.
When replacing parts, ensure that you use parts specified by
the manufacturer.
When service or repairs have been done, perform routine
safety checks to verify that the system is operating correctly.
Avoid using the system near water, in direct sunlight, or near
a heating device.
Cover the unit when not in use.
Page 7
v
Table of Contents
Chapter 1:Overview
1.1 About the Transport GT20 B3970-U . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Product Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
1.4 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.5 About the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5.1 Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.5.2 Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.5.3 LED Definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
1.5.4 Internal View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5.5 Motherboard (S3970) Block Diagram . . . . . . . . . . . . . . . . . 8
1.5.6 Motherboard Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Chapter 2:Setting Up
2.0.1 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2.0.2 Work Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2.0.3 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
2.0.4 Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1 Rack Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1.1 Installing the Server in a Rack. . . . . . . . . . . . . . . . . . . . . . 13
2.2 Installing Motherboard Components. . . . . . . . . . . . . . . . . . . . . . . 19
2.2.1 Removing the Chassis Cover. . . . . . . . . . . . . . . . . . . . . . . 19
2.2.2 Installing the Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2.2.3 Installing the CPU and Heatsink . . . . . . . . . . . . . . . . . . . .21
2.2.4 Installing the PCI-X Card . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.3 Installing the External Hard Drive . . . . . . . . . . . . . . . . . . . . . . . .26
2.4 Installing the Slim FDD (Option) . . . . . . . . . . . . . . . . . . . . . . . . .28
Chapter 3:Replacing Pre-Installed Components
3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
3.1.1 Work Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
3.1.2 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
3.1.3 Precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.2 Disassembly Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
3.3 Removing the Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.4 Replacing Motherboard Components . . . . . . . . . . . . . . . . . . . . . . 35
3.4.1 Disconnecting All Motherboard Cables . . . . . . . . . . . . . .35
3.4.2 Removing the Motherboard. . . . . . . . . . . . . . . . . . . . . . . .36
3.5 Replacing the Slim CD-ROM . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
3.6 Replacing the LED Control Board . . . . . . . . . . . . . . . . . . . . . . . . 39
Page 8
vi
3.7 Replacing the M1012 Adapter Board . . . . . . . . . . . . . . . . . . . . . . 41
3.7.1 M1012 Adapter Board Features for B3970-U . . . . . . . . . .43
3.7.2 M1012 Adapter Board Connector Pin Definition . . . . . . . 44
3.8 Replacing the SATA Backplane . . . . . . . . . . . . . . . . . . . . . . . . . .49
3.8.1 SAS/SATA Backplane (M1208) Features. . . . . . . . . . . . .51
3.9 Replacing the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Appendix I: BIOS Differences
Appendix II: Cable Connection Tables
Appendix III: Installing SMDC Cards
Page 9
Chapter 1: Overview 1
Chapter 1: Overview
1.1 About the Transport GT20 B3970-U
Congratulations on your purchase of the TYAN Transport
TM
GT20 (B3970-U), a highly-optimized rack-mountable bareb­one system. The Transport GT20 (B3970-U) is designed to
support AMD
®
Opteron™ 2000 940-pin processor, providing
a rich feature set and incredible performance. Leveraging
advanced technology from AMD
®
, the Transport GT20 (B3970-U) server system is capable of offering scalable 32 and 64-bit computing, high-bandwidth memory design, and a
lightning-fast PCI-X bus implementation. The Transport
TM
GT20 (B3970-U) not only empowers your company in today’s demanding IT environment but also offers a smooth path for future application usage.
TYAN is also proud to deliver the Transport
TM
GT20 (B3970­U) in SATA flavor while supporting up to four (4) hot-swap hard drives, one (1) slim CD-ROM and one (1) optional slim
floppy disk drive (not included). The Transport
TM
GT20 (B3970-U) uses TYAN’s latest tooling-made chassis featuring a robust structure, tool-less and modularized design, and a solid mechanical enclosure. All of this provides the Trans-
port
TM
GT20 (B3970-U) the power and flexibility to meet the
needs of nearly any server application.
1.2 Product Model
Model HDD Bays
Hot-Swap
Support
HDD
Backplane
B3970-UG20V4H
Removable,
4 HDDs
Yes 4-port SATA
Page 10
2 Chapter 1: Overview
1.3 Features
Enclosure
• Industry 19” rack-mountable 1U chassis – (4) 3.5” HDD bays – (1) slim CD-ROM bay
• Dimension: D 22.4 x W 17.2 x H
1.72 inch (568x436x43.6mm)
Processor
• (1) 1207-pin ZIF socket for AMD
®
Opteron 2000 Series processors
• Integrated 144-bit DDR2 memory controller
Chipset
• Broadcom BCM5785 (HT-1000) core-logic
• SMSC SCH4307 Super I/O
Memory
• Dual channel memory bus
• (8) 240pin DIMM sockets
• Registered, ECC DDR2 module supported, up to 16GB DDR2­667/533
Expansion Slots
• (1) 64-bit / 133MHz PCI-X slot on riser card (Riser card model: M2055)
• (1) Tyan ”TARO” SO-DIMM socket
Back I/O Ports
• Stacked PS/2 mouse & keyboard ports
• Stacked 2 USB 2.0 ports
• (1) 9-pin COM port
• (1) 15-pin VGA port
• (2) RJ45 connectors
Front Panel Features
• I/O – (2) USB 2.0 ports
• LED indicators – Power LED – (2) LAN LEDs –ID LED – HDD active LEDs
• Switches – Power
–Reset –ID
Storage
• Pre-installed slim type 24x CD-ROM
• (4) hot-swappable, SATA HDD
Networking
• (2) Intel i8254PI GbE LAN control­lers
Video
•ATI® XGI Volari Z7 (XG20)
• 16MB frame buffer memory
Motherboard
• TYAN Tomcat S3970-U 1U system board
• ATX footprint 12” x 10.2” (304.8mm x 259.1mm)
BIOS
• AMI BIOS on 8Mbit LCP Flash ROM
• Serial Console Redirect
• USB boot supported
• ACPI supported
• PnP, DMI2.0, WfM2.0 Power Man­agement
Server Management
• (2) SMSC EMC6D103 Hardware Monitoring IC.
• Temperature and voltage monitoring
• Watch dog timer support
• Chassis intrusion detection
System Cooling
• (4) Sunon 40*40*28mm 14500rpm heavy-duty fans
• (1) passive CPU heatsink
Power Supply
• PS 12V, 1U, 350W
Regulatory
• FCC Class B (Declaration of Con­formity)
• CE (Declaration of Conformity)
Environment Temperature
• Operating temperature 5oC~35oC
• Non-operating temperature -40
o
C ~
70
o
C
Page 11
Chapter 1: Overview 3
1.4 Unpacking
If any items are missing or appear damaged, contact your retailer or browse to TYAN’s Web site for service: http://www.tyan.com.
The Web site also provides information on other TYAN prod­ucts, plus FAQs, compatibility lists, BIOS settings, and more.
1 x Tyan driver CD
Power Cables Left to right: Europe, US
HDD Screws
Mounting Ears & Screws
FDD Kit
FDD Cable
FDD Backplane Cable
FDD Installing Rails & Screws
Heatsink
Air Duct
Page 12
4 Chapter 1: Overview
Mainboard ManualBarebone Manual
Rail Kit
Mounting Bracket x 4
Sliding Brackets Front L-Bracket x 2 Rear L-Bracket x 2
Screws Kit
Sliding Rails x 2
Page 13
Chapter 1: Overview 5
1.5 About the Product
The following views show you the product.
1.5.1 Front View
1.5.2 Rear View
CD-ROM Drive
Hard Drive Bay x 4
HDD activity LED
Power switch
Power LED
Reset switch
USB ports
Warning LED
2 x LAN LEDs
ID switch
NMI switch
ID LED
Power Supply Fan Aperture
PS/2 Mouse/Keyboard Ports
Serial Port
VGA Port
PCI-X Slot Opening
Power Supply Socket
LAN Port (NIC2)
LAN Port (NIC1)
ID LED
2 USB Ports
Page 14
6 Chapter 1: Overview
1.5.3 LED Definition
Front Panel
Rear I/O LED
LED Color State Description
Power Green
OFF
ON OFF
Power ON Power OFF
HDD Activity Amber
OFF
Random Blink OFF
HDD access activity No disk activity
LAN1/LAN2 Activity Green
Green OFF
ON Blinking OFF
LAN linked LAN accessing No LAN linked
Warni ng Red
OFF
ON OFF
Fan fails Normal
ID LED Blue
OFF
ON OFF
System is identified System is not identified
Hot Swappable HDD Tray Power LED
Green OFF
ON OFF
Power connected Power disconnected
Hot Swappable SATA HDD Access LED
Amber OFF
Random Blinking OFF
HDD access activity No disk activity
Hot Swappable SAS HDD Access LED
Amber Amber OFF
ON Random Blinking OFF
HDD ready HDD access activity HDD not ready
LED Color State Description
RJ45 NIC1 Linkage (Left Side)
Green Green OFF
ON Blinking OFF
LAN linked LAN accessing No LAN linked
RJ45 NIC1 Mode (Right Side)
Amber Green OFF
ON ON OFF
Gigabit mode 100M mode 10M mode
RJ45 NIC2 Linkage (Left Side)
Green Green OFF
ON Blinking OFF
LAN linked LAN accessing No LAN linked
RJ45 NIC2 Mode (Right Side)
Amber Green OFF
ON ON OFF
Gigabit mode 100M mode 10M mode
ID LED Blue
OFF
ON OFF
System is identified System is not identified
Page 15
Chapter 1: Overview 7
1.5.4 Internal View
1 2
6
11
9
10
5
7
8
3
12
4
1. PCI-X Slot
2. Memory Slots
3. Power Connector
4. EPS Power Supply
5. System Fans
6. M1012 Adapter Board
7. SATA Backplane
8. LED Control Board Cable
9. SATA Cables (4)
10. USB Cable
11. CD-ROM Cable
12. Four SATA HDD Bays
13. Slim CD-ROM
13
Page 16
8 Chapter 1: Overview
1.5.5 Motherboard (S3970) Block Diagram
Page 17
Chapter 1: Overview 9
1.5.6 Motherboard Layout
Page 18
10 Chapter 1: Overview
Jumpers & Connectors
Jumper
/Connector
Function
J2/J3 3-pin Back Panel Fan Connector
J4/J22/J23/ J35
4-pin Fan Connector with Speed Control
J6 COM2 Header
J24 USB Front Panel Connector
J25 Front Panel SATA LED Pin Header
J26 Front Panel Header
J27 LCM Pin Header
J29 IPMB Pin Header
JP1 VGA Enable/Disable Jumper
(Close 1-2) Default, Enabled (Close 2-3) Disabled
JP2/JP3 SMDC/ASF2.0 Select Jumper
(Close 1-2) Default, support ASF2.0 (Close 2-3) support SMDC card
JP6 PCI-X Frequency Select Jumper
Open: 100MHz Installed: Default, 133MHz
JP8 Clear CMOS Jumper
(Close 1-2) Default (Close 2-3) Clear CMOS
J21 TARO SO-DIMM Socket
J36 SMDC Connector
J5/J28 Reserved for OEM only
Page 19
Chapter 2: Setting Up 11
Chapter 2: Setting Up
2.0.1 Before You Begin
This chapter explains how to install the CPU, CPU heatsink, memory modules, and hard drives. Instructions on inserting a PCI-X card are also given.
Take note of the precautions mentioned in this section when installing your system.
2.0.2 Work Area
Make sure you have a stable, clean working environment. Dust and dirt can get into components and cause malfunc­tions. Use containers to keep small components separated. Putting all small components in separate containers prevents them from becoming lost. Adequate lighting and proper tools can prevent you from accidentally damaging the internal components.
2.0.3 Tools
The following procedures require only a few tools, including the following:
A cross head (Phillips) screwdriver
A grounding strap or an anti-static pad
Most of the electrical and mechanical connections can be dis­connected using your fingers. It is recommended that you do not use needle-nosed pliers to remove connectors as these can damage the soft metal or plastic parts of the connectors.
Page 20
12 Chapter 2: Setting Up
2.0.4 Precautions
Components and electronic circuit boards can be damaged by discharges of static electricity. Working on a system that is connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to the Transport GT20 or injury to yourself.
Ground yourself properly before removing the top
cover of the system. Unplug the power from the power supply and then touch a safely grounded object to release static charge (i.e. power supply case). If available, wear a grounded wrist strap. Alter­natively, discharge any static electricity by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appliance.
Avoid touching motherboard components, IC chips,
connectors, memory modules, and leads.
The motherboard is pre-installed in the system.
When removing the motherboard, always place it on a grounded anti-static surface until you are ready to reinstall it.
Hold electronic circuit boards by the edges only. Do
not touch the components on the board unless it is necessary to do so. Do not flex or stress circuit boards.
Leave all components inside the static-proof packag-
ing that they ship with until they are ready for installa­tion.
After replacing optional devices, make sure all
screws, springs, or other small parts are in place and are not left loose inside the case. Metallic parts or metal flakes can cause electrical shorts.
Notes:
All connectors are keyed to only attach one way.
Always use the correct screw size as indicated in the procedures.
Page 21
Chapter 2: Setting Up 13
2.1 Rack Mounting
After installing the necessary components, the Transport GT20 can be mounted in a rack using the supplied rack mounting kit.
Rack mounting kit
Sliding Rails x 2:
Sliding Brackets x 4 (Front x 2, Rear x 2)
Mounting Ears x 2
Screws Kit x 1
Mounting Brackets x 4
2.1.1 Installing the Server in a Rack
Follow these instructions to mount the GT20 into an industry standard 19" rack.
NOTE: Before mounting the Transport GT20 in a rack, ensure that all internal components have been installed and that the unit has been fully tested. Maintenance can be per­formed on the unit while in a rack but it is preferable to install the device in a fully operational condition.
Screws List (including screws for SMDC)
A: Flat 6#-32 x4~x16
B: B-type 6#-32 x4
C: M4-4L x8
D: M4-5L x4
E: M4-8L x8
F: M4-15L x2
G: 13.5mm stand-off x1
A
B
C
D
E
F
G
Page 22
14 Chapter 2: Setting Up
Installing the Inner Rails to Chassis
1. Screw the mounting ear to each side of GT20 as shown using 2 screws from the supplied screws kit.
2. Draw out the inner rails from rail assembly. Install inner rails to left and right sides of chassis using 2 M4-5L(D) screws for each side.
Installing Outer Rails to the Rack
3. Measure the distance between inner side of the front and rear mounting brackets in the rack.
Mounting Ears
Page 23
Chapter 2: Setting Up 15
4. Locate the front and rear brackets.
5. Reserve 40mm on the front bracket. Secure the front bracket to outer rail with 2 M4-4L(C) screws.
Rear Bracket x2
Front Bracket x2
Page 24
16 Chapter 2: Setting Up
6. Reserve the distance same as in Step 2 on rear bracket. Secure the rear bracket to outer rail with 2 M4-4L(C) screws.
7. Secure the outer rail to the rack using 2 brackets and 4 M4-8L(E) screws for each side (A). Secure the mounting brackets from inside, not outside, of the rack (B).
Mounting Bracket
A
B
Page 25
Chapter 2: Setting Up 17
Rackmounting the Server
8. Draw out the middle rail to the latch position.
9. Lift the chassis and then insert the inner slide rails into the middle rails.
10. Push the chassis in and press the latch key (A). Then push the whole system into the rack (B).
A
B
Page 26
18 Chapter 2: Setting Up
11. Secure the mounting ears of chassis to the rack with 2 M4-15L(F) screws.
NOTE: To avoid injury, it is strongly recommended that two people lift the GT20 into the place while a third per­son screws it to the rack.
Page 27
Chapter 2: Setting Up 19
2.2 Installing Motherboard Components
This section describes how to install components on to the motherboard, including CPU, memory modules and PCI card.
2.2.1 Removing the Chassis Cover
Follow these instructions to remove the Transport GT20 chassis cover.
1. Remove the screw on the back side. Then slide the chas­sis cover in the direction of arrow.
2. Lift the cover off.
Page 28
20 Chapter 2: Setting Up
2.2.2 Installing the Memory
Follow these instructions to install the memory modules on the motherboard.
1. Locate the memory slots on the motherboard.
2. Press the memory slot locking levers in the direction of the arrows as shown in the following illustration.
3. Align the memory module with the slot. When inserted properly, the memory slot locking levers lock automati­cally onto the indentations at the ends of the module. For optimal system operation, please install memory in pairs.
Page 29
Chapter 2: Setting Up 21
2.2.3 Installing the CPU and Heatsink
Follow these instructions to install the CPU and CPU heat­sink.
1. Locate the CPU socket.
2. Take off the CPU protection cap.
3. Pull the CPU lever up to unlock the CPU socket.
Page 30
22 Chapter 2: Setting Up
4. Open the socket in the direction as illustrated.
5. Place the CPU on the CPU socket, ensuring that pin 1 is located in the right direction.
6. Close the cover in the direction shown.
Page 31
Chapter 2: Setting Up 23
7. Press the CPU socket lever down in the direction shown to secure the CPU.
8. Secure the heatsink to the motherboard using two screws.
NOTE: Remember to install the washer and nut while installing the screws.
9. Place the air duct with one screw.
Page 32
24 Chapter 2: Setting Up
2.2.4 Installing the PCI-X Card
Follow these instructions to install a PCI-X card.
1. Push the tab of PCI-X slot on the rear panel in the direc­tion as shown to release the I/O shield.
2. Move the I/O shield to right as shown and then take off the I/O shield.
3. Insert the PCI-X card in the directions of arrow as shown.
Page 33
Chapter 2: Setting Up 25
4. Push the tab of PCI-X slot on the rear panel in the direc­tion as shown to secure PCI-X card.
Page 34
26 Chapter 2: Setting Up
2.3 Installing the External Hard Drive
The GT20 chassis kit supports external SATA or SAS hard drives.
Follow these instructions to install an external SATA or SAS hard drive.
1. Press the locking lever latch in the direction of arrow (A) and then pull the locking lever open (B).
2. Slide the drive tray out.
3. Place a hard drive into the drive tray.
A B
Page 35
Chapter 2: Setting Up 27
4. Using 4 HDD screws to secure the HDD.
5. Reinsert the drive tray into the chassis (A), ensuring that the drive tray is completely inserted into the chassis (B).
6. Pressing the locking lever to secure the hard drive tray.
A
B
Page 36
28 Chapter 2: Setting Up
2.4 Installing the Slim FDD (Option)
1. Locate the two FDD rails and screws from the FDD kit. Secure the two rails to FDD using four screws.
2. Connect the FFC cable to FDD.
3. Using a screw driver to pull open the door of FDD tray.
4. Insert FDD module into the tray.
FDD Rails & Screws
Page 37
Chapter 2: Setting Up 29
5. Connect the FFC cable to the connector on M1012 adapter board.
6. Locate the FDD cable from FDD kit. Connect the wrinkle side to the connector on M1012 adapter board. Refer to the picture below for the correct direction.
7. Connect the other side to the connector on motherboard.
For M1012
For Mainboard
Page 38
30 Chapter 2: Setting Up
NOTE
Page 39
Chapter 3: Replacing Pre-Installed Components 31
Chapter 3: Replacing Pre-Installed
Components
3.1 Introduction
This chapter explains how to replace pre installed compo­nents including the motherboard, LED control board, HDD, and CD-ROM drive.
Take note of the precautions in this section when installing your system.
3.1.1 Work Area
Make sure you have a stable, clean working environment. Dust and dirt can get into components and cause malfunc­tions. Use containers to keep small components separated. Putting all small components in separate containers keeps them from becoming lost. Adequate lighting and proper tools can prevent you from accidentally damaging the internal components.
3.1.2 Tools
The procedures that follow require only a few tools, including the following:
A cross head (Phillips) screwdriver
A grounding strap or an anti-static pad
Most of the electrical and mechanical connections can be dis­connected using your fingers. It is recommended that you do not use needle-nosed pliers to remove connectors as these can damage the soft metal or plastic parts of the connectors.
Page 40
32 Chapter 3: Replacing Pre-Installed Components
3.1.3 Precautions
Components and electronic circuit boards can be damaged by static electricity. Working on a system that is connected to a power supply can be extremely dangerous. Follow the guidelines below to avoid damage to the Transport GT20 or injury to yourself.
Ground yourself properly before removing the top
cover of the system. Unplug the power from your computer power supply and then touch a safely grounded object to release static charge (i.e. power supply case). If available, wear a grounded wrist strap. Alternatively, discharge any static electricity by touching the bare metal chassis of the unit case, or the bare metal body of any other grounded appli­ance.
Avoid touching motherboard components, IC chips,
connectors, memory modules, and leads.
The motherboard is pre-installed in the system.
When removing the motherboard, always place it on a grounded anti-static surface until you are ready to reinstall it.
Hold electronic circuit boards by the edges only. Do
not touch the components on the board unless it is necessary to do so. Do not flex or stress circuit boards.
Leave all components inside the static-proof packag-
ing that they ship with until they are ready for installa­tion.
After replacing optional devices, make sure all
screws, springs, or other small parts are in place and are not left loose inside the case. Metallic parts or metal flakes can cause electrical shorts.
Notes:
All connectors are keyed to only attach one way.
Always use the correct screw size as indicated in the procedures.
Page 41
Chapter 3: Replacing Pre-Installed Components 33
3.2 Disassembly Flowchart
The following flowchart outlines the disassembly procedure.
Rear Components
Chassis rear cover
Air duct
Mainboard
DIMMs
CPU/heatsink assembly
PCI card
Mainboard
Power supply
Front Components
FAN
PCBs
CD-ROM
M1012
Adapter Board
Control Board
HDD Backplane
Chassis rear cover
Page 42
34 Chapter 3: Replacing Pre-Installed Components
3.3 Removing the Cover
Before replacing any parts you must remove the chassis cover.
Follow these instructions to remove the cover of the Transport GT20 chassis cover.
1. Remove the screw on the back side. Then slide the chas­sis cover in the direction of arrow.
2. Lift the cover off.
Page 43
Chapter 3: Replacing Pre-Installed Components 35
3.4 Replacing Motherboard Components
Follow these instructions to replace motherboard compo­nents, including the motherboard.
3.4.1 Disconnecting All Motherboard Cables
Before replacing the motherboard or certain components, remove cables connected to the motherboard. Follow these instructions to remove all motherboard cabling.
1. Disconnect ATX power cables.
2. Disconnect CD-ROM drive cable.
EPS 12V Power
Main Power
Page 44
36 Chapter 3: Replacing Pre-Installed Components
3. Disconnect all cables from front panel, USB, fans and SATA connectors.
3.4.2 Removing the Motherboard
After removing all of those cables, follow these instructions to remove the motherboard from the chassis.
1. Remove eight screws securing the motherboard to the chassis.
2. Remove the motherboard.
Page 45
Chapter 3: Replacing Pre-Installed Components 37
3.5 Replacing the Slim CD-ROM
Follow these instructions to replace the CD-ROM.
1. Remove power and data cables from the slim CD-ROM adapter.
2. Press the tab in the directions as show to release the CD­ROM drive.
Data Cable
Power Cable
Page 46
38 Chapter 3: Replacing Pre-Installed Components
3. The CD-ROM drive will be freed from the drive bay after pressing the tab.
4. Remove two screws that secure CD-ROM drive to the bracket.
5. Replace the CD-ROM drive.
6. Secure CD-ROM to the bracket using two screws. Then replace the unit into the drive bay and connect the CD­ROM power and data cables.
Page 47
Chapter 3: Replacing Pre-Installed Components 39
3.6 Replacing the LED Control Board
Follow these instructions to replace the LED control board.
1. Remove two screws securing LED control board unit to the chassis.
2. Lift the LED control board unit free of the chassis.
3. Remove three screws securing LED control board to the bracket.
Page 48
40 Chapter 3: Replacing Pre-Installed Components
4. Lift the LED control board free from the chassis. After replacement, insert the unit into the chassis.
Page 49
Chapter 3: Replacing Pre-Installed Components 41
3.7 Replacing the M1012 Adapter Board
1. Remove all of those cables connected to the adapter board, including fan cables, CD-ROM power cable, front LED panel cable, power cables, and SATA cables.
SATA Cables
CD-ROM Power Cable
2x power cables on
1x power cable on M1012
SATA backplane
Front panel control board cable
Front Panel
Fan Tach
LAN/ID
Page 50
42 Chapter 3: Replacing Pre-Installed Components
2. Remove six screws to release the adapter board. Refer to p.46 for the location.
Fan Cables
Page 51
Chapter 3: Replacing Pre-Installed Components 43
3.7.1 M1012 Adapter Board Features for B3970-U
J16: LCM Connector
J7:Fan Tach & PWM Connector
J5: Fan Connector
J9: Fan Connector
J11: Fan Connector
J10: Fan Connector
J2: Front Panel Connector
J6: Fan Connector
FDD2: Slim FDD Connector
J15: LCM Connector
PW2: Power Connector
JP1: Fan Input Select
Connector
J3: LAN/ID LED Connector
FDD1: Standard Floppy Connector
J1: Front Panel Connector
JP2: Fan Minimum
Voltage Input Select
Connector
J4: Fan Tach & PWM Connector
J14: Fan Tach Connector
J19: CD-ROM Power
Connector
J8: PWM Connector
J13: Fan Tach Connector
Page 52
44 Chapter 3: Replacing Pre-Installed Components
3.7.2 M1012 Adapter Board Connector Pin Definition
J1 TYFP Front Panel Connector
J2 Front Panel Connector
1 HDLED+ 2 PW_LED+
3 HDLED- 4 PW_LED -
5 RESET- 6 PWR_SW+
7 RESET+ 8 PWR_SW -
9 VOLTAGE5 10 WLED+
11 EXT_INT 12 WLED-
13 V5SB 14 KEY PIN
15 ICH_SMBDAT 16 GND
17 ICH_SMBCLK 18 INTRU#
1 HDLED+ 2 HDLED-
3 RESET+ 4 RESET-
5PW_LED+ 6PW_LED-
7WLED+ 8WLED-
9 ICH_SMBDAT 10 ICH_SMBCLK
11 EXT_INT 12 VOLTAGE5
13 V5SB 14 INTRU#
15 PWR_SW+ 16 PWR_SW -
17 LAN1_LED+ 18 LAN1_LED-
19 LAN2_LED+ 20 LAN2_LED-
21 LAN3_LED+ 22 LAN3_LED-
23 ID_LED+ 24 ID_LED-
25 ID_SW+ 26 ID_SW-
27 KEY PIN 28 NC
Page 53
Chapter 3: Replacing Pre-Installed Components 45
J3 LAN/ID LED Connector
FAN Signal Related Connector Pin Definition
NOTE: The FAN signal naming is based on HW circuit design only. It might
be different from the system fan naming.
J4 Fan TACH & PWM Connector
J7 Fan TACH & PWM Connector
J8 PWM Connector
1 LAN1_LED+ 2 LAN1_LED-
3 LAN2_LED+ 4 LAN2_LED-
5 LAN3_LED+ 6 LAN3_LED-
7 ID_LED+ 8 ID_LED-
9 ID_SW+ 10 ID_SW-
11 KEY PIN 12 NC
1GND
2NC
3 FAN1_TACH
4 PWM1 (Default)
1GND
2NC
3 FAN7_TACH
4 PWM1 (Default)
1GND
2PWM2
3 FAN1_TACH
Page 54
46 Chapter 3: Replacing Pre-Installed Components
J13 Fan TACH Connector
J14 Fan TACH Connector
J6 Fan Connector
1 GND 2 FAN1_TACH
3 GND 4 FAN2_TACH
5 GND 6 FAN3_TACH
7 KEY PIN 8 NC
1 GND 2 FAN1_TACH
3 GND 4 FAN2_TACH
5 GND 6 FAN3_TACH
7 GND 8 FAN4_TACH
9 GND 10 FAN5_TACH
11 GND 12 FAN6_TACH
13 GND 14 FAN7_TACH
15 GND 16 FAN8_TACH
17 GND 18 FAN9_TACH
19 GND 20 FAN10_TACH
21 KEY PIN 22 PWM
1 FAN1_12VPWM
2 FAN1_TACH
3GND
4GND
5 FAN2_TACH
6 FAN2_12VPWM
Page 55
Chapter 3: Replacing Pre-Installed Components 47
J10 Fan Connector
J11 Fan Connector
J9 Fan Connector
1 FAN3_12VPWM
2 FAN3_TACH
3GND
4GND
5 FAN4_TACH
6 FAN4_12VPWM
1 FAN5_12VPWM
2 FAN5_TACH
3GND
4GND
5 FAN6_TACH
6 FAN6_12VPWM
1 FAN7_12VPWM
2 FAN7_TACH
3GND
4GND
5 FAN8_TACH
6 FAN8_12VPWM
Page 56
48 Chapter 3: Replacing Pre-Installed Components
J5 Fan Connector
J15 & J16 LCM Connectors
JP1 Fan Input Select Connector
JP2 Fan Input Select Connector
1 FAN9_12VPWM
2 FAN9_TACH
3GND
4GND
5 FAN10_TACH
6 FAN10_12VPWM
1 LCM_+5V 2 LCM_SIN
3KEY PIN 4GND
5 LCM_+5VSB 6 LCM_SOUT
Pin1 & Pin2 Close Fan PWM signal from J8
Pin2 & Pin3 Close Fan PWM signal from J4, J7
& J14 (Default)
Pin1 & Pin2 Close 0V
Pin2 & Pin3 Close +5V (Default)
Page 57
Chapter 3: Replacing Pre-Installed Components 49
3.8 Replacing the SATA Backplane
1. After removing the M1012 adapter board, disconnect those cables connected to the SATA backplane, including SATA and power cables.
2. Grab the two tabs to lift the SATA backplane off.
3. Remove ten screws that secure the bracket to the adapter board.
Page 58
50 Chapter 3: Replacing Pre-Installed Components
4. Release the adapter board free from the bracket.
5. After replacement, place and secure the unit into the chassis following the reverse procedures from step 1 to 4 after done.
Page 59
Chapter 3: Replacing Pre-Installed Components 51
3.8.1 SAS/SATA Backplane (M1208) Features
U4, SAS/SATA4 Connector
U3, SAS/SATA3 Connector
U2, SAS/SATA2 Connector
U1, SAS/SATA 1 Connector
HDD Access LED
HDD Power LED
Page 60
52 Chapter 3: Replacing Pre-Installed Components
PW1 Power Connector
J4, SAS/SATA 4
J3, SAS/SATA 3
J2, SAS/SATA 2
J1, SAS/SATA 1
PW2 Power Connector
Connector
Connector
Connector
Connector
Page 61
Chapter 3: Replacing Pre-Installed Components 53
3.9 Replacing the Power Supply
1. Remove two screws securing the power supply to the chassis.
2. Remove the screw securing fan assembly to the chassis.
3. Lift the power supply free from the chassis. After replace­ment, place and secure the unit into the chassis following the reverse procedures from steps 1 to 2.
Page 62
54 Chapter 3: Replacing Pre-Installed Components
NOTE
Page 63
55
Appendix I: BIOS Differences
The BIOS of B3970-U is similar to the BIOS of S3970G2N-U. There is only one menu different. You may refer to the attached motherboard manual for the complete BIOS infor­mation. The differences between B3970-U and S3970G2N-U is on the “Advanced/Hardware Health Configuration” menu. See the following for the differences.
B3970-U Advanced/Hardware Health Configuration
BIOS Setup Utility
Advanced
Hardware Health Configuration Enables Hardware
Health Monitoring Device
ÅÆ Select Screen ÇÈ Select Item
+ - Change Option F1 General Help F10 Save and Exit ESC Exit
H/W Health Function FAN Select AutoFAN1 Power Control PWM Minimal Duty Cycle FAN Fail LED Indicator
Hardware Health Event Monitoring
[Enabled] [3Pin FAN] [Enabled] [10% Duty Cycle] [Enabled]
XMainboard Voltages Report CPU1 Temperature Mainboard Ambient Temp.
System FAN1 Speed System FAN2 Speed System FAN3 Speed System FAN4 Speed
:xx ºC/ xxx ºF :xx ºC/ xxx ºF
:xxxx RPM :xxxx RPM :xxxx RPM :xxxx RPM
Page 64
56
S3970 Advanced/Hardware Health Configuration
Table of Differences
BIOS Setup Utility
Advanced
Hardware Health Configuration Enables Hardware
Health Monitoring Device
ÅÆ Select Screen ÇÈ Select Item
+ - Change Option Tab Select Field F1 General Help F10 Save and Exit ESC Exit
H/W Health Function FAN Select Auto FAN1, 2 Power Control Auto FAN 3, 4 Power Control FAN Fail LED Indicator
Hardware Health Event Monitoring
[Enabled] [4Pin FAN] [Disabled] [Disabled] [Disabled]
XMainboard Voltages Report
CPU1 Temperature Mainboard Ambient Temp.
FAN1 Speed FAN2 Speed FAN3 Speed FAN4 Speed
:xx ºC/ xxx ºF :xx ºC/ xxx ºF
:xxxx RPM :xxxx RPM :xxxx RPM :xxxx RPM
S3970 B3970-U
FAN Select 4Pin FAN 3Pin FAN
Fan Power Control Disabled Enabled
PWM Minimal Duty Cycle
[10% Duty Cycle] --
FAN Fail LED Indicator
Disabled Enabled
Hardware Monitor Fan
FAN1 Speed FAN2 Speed FAN3 Speed FAN4 Speed
System FAN1 Speed System FAN2 Speed System FAN3 Speed System FAN4 Speed
Page 65
57
Appendix II: Cable Connection Tables
SATA Cable
FAN Cable
Table 1: B3970-UG20S4H Model
M1204 SATA Backplane Connect to Motherboard
SATA 1 Æ SATA 1
SATA 2 Æ SATA 2
SATA 3 Æ SATA 3
SATA 4 Æ SATA 4
Table 2: System Fan to M1012 Adapter Board
System Fan Connect to M1012
Fan 1 Æ J6 Fan Connector
Fan 2 Æ J10 Fan Connector
Fan 3 Æ J11 Fan Connector
Fan 4 Æ J9 Fan Connector
Fan 5 Æ J5 Fan Connector
Table 3: M1012 Adapter Board to Motherboard
M1012 Connect to Motherboard Fan
J14 Æ J25, J27
J7 Æ J20
Page 66
58
Power Supply Cable
Table 4: Power Supply to Motherboard
Power Supply Connect to Motherboard
P1 24-pin power cable Æ PW1 24-pin connector
P2 8-pin power cable Æ PW2 8-pin connector
Table 5: Power Supply to M1012 Adapter Board
Power Supply Connect to M1012
P3 4-pin power cable Æ PW2 4-pin connector
Table 6: Power Supply to M1208 SATA Backplane
Power Supply Connect to M1204
P4 4-pin power cable v PW1 4-pin connector
P6 4-pin power cable Æ PW2 4-pin connector
Page 67
59
Other Cables
Table 7: M1012 Adapter Board to Motherboard
M1012 Connect to Motherboard
J1 Front Panel connector Æ J24 (TYFP1)
J3 (LAN / ID LED) Æ J5 (TYFP2)
Table 8: M1003 Front Panel Control Board Related Cable
M1003 J1 USB connector Æ Motherboard J22 USB2
M1003 J2 connector Æ M1012 J2 connector
Table 9: CD-ROM Related Cable
Motherboard PRE-IDE con-
nector
Æ CD-ROM Backplane
M1012 J19 power connector Æ CD-ROM Backplane
Table 10: FDD Related Cable (Option)
M1012 FDD1 connector Æ Motherboard JB1 FDD
M1012 FDD2 connector Æ Slim FDD drive
Page 68
60
Appendix III: Installing SMDC Cards
The following provides you with the information on installing SMDC cards. You may refer to the following for installing M3289 or M3290 into HDD tray or chassis.
Screws List (including screws for Rail)
A: Flat 6#-32 x4~x16
B: B-type 6#-32 x4
C: M4-4L x8
D: M4-5L x4
E: M4-8L x8
F: M4-15L x2
G: 13.5mm stand-off x1
A
B
C
D
E
F
G
Page 69
61
Installing M3289 into HDD Tray
1. Fold up the cable.
2. a: Choose a HDD tray. b: Insert the cable into the rear of HDD tray. c: Pull the cable out.
3. Connect the cable to M3289.
Page 70
62
4. Align M3289 in reverse with 4 “M1” stand-offs. Secure the SMDC with 4 screws as illustrated.
5. Secure M3289 onto HDD tray as illustrated.
6. Insert and secure the HDD tray. NOTE: For internal or dummy HDD tray, secure the HDD tray with 1 or 2 screws.
7. Arrange and connect the cable to SMDC connector on mainboard. Be careful not to block the air flow.
Page 71
63
Installing M3290/M3291 into HDD tray
1. Secure a removable stand-off of 13.5mm to the location of “M2” stand-off as illustrated on SMDC bracket.
2. Secure M3290 in reverse to 4 “M2” stand-offs on bracket.
3. a: Choose a HDD tray. NOTE: Refer to the location of SMDC connector on mainboard for choosing a HDD tray. b: Secure SMDC to the HDD tray.
Page 72
64
4. a: Inset the cable into the rear of HDD tray. b: Connect the cable to M3290. c: Insert and secure HDD tray.
5. Arrange and connect the cable to SMDC connector on mainboard. Be careful not to block the air flow.
Page 73
65
Installing M3290/M3291 into GT24 Chassis
NOTE: The products produced now may not support the pro­cedures below. We’ll provide you with the upgraded models as soon as possible.
1. Disconnect the power connectors on HDD backplane and M1012.
2. Push the power cables aside.
3. Align M3290 with 4 “M2” PC stand-offs. Secure M3290 to mainboard with 4 screws.
Page 74
66
4. Connect the cable to M3290. Arrange and connect the cable to SMDC connector on mainboard. Be careful not to block the air flow.
5. Reconnect the power connectors on HDD backplane and M1012.
Page 75
67
NOTE
Page 76
68
Technical Support
If a problem arises with your system, you should first turn to your dealer for direct support. Your system has most likely been configured or designed by them and they should have the best idea of what hardware and software your system contains. Hence, they should be of the most assistance for you. Furthermore, if you purchased your system from a dealer near you, take the system to them directly to have it serviced instead of attempting to do so yourself (which can have expensive consequences).
If these options are not available for you then Tyan Computer Corporation can help.Besides designing innovative and qual­ity products for over a decade, Tyan has continuously offered customers service beyond their expectations. Tyan's website (www.tyan.com) provides easy-to-access resources such as in-depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis, memory and much more. With all these convenient resources just a few keystrokes away, users can easily find the latest software and operating system components to keep their systems running as powerful and productive as possi­ble. Tyan also ranks high for its commitment to fast and friendly customer support through email. By offering plenty of options for users, Tyan serves multiple market segments with the industry's most competitive services to support them.
"Tyan's tech support is some of the most impressive we've seen, with great response time and exceptional organization in general" - Anandtech.com
Please feel free to contact us directly for this service at tech-
support@tyan.com
Help Resources:
1. See the beep codes section of this manual.
2. See the TYAN website for FAQ’s, bulletins, driver updates, and other information: http://www.tyan.com
Page 77
69
3. Contact your dealer for help BEFORE calling TYAN.
4. Check the TYAN user group: alt.comp.periphs.main­board.TYAN
Returning Merchandise for Service
During the warranty period, contact your distributor or system vendor FIRST for any product problems. This warranty only covers normal customer use and does not cover damages incurred during shipping or failure due to the alteration, mis­use, abuse, or improper maintenance of products.
NOTE: A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered. You may obtain service by calling the manufacturer for a Return Merchandise Authorization (RMA) number. The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed pre­paid. TYAN will pay to have the board shipped back to you.
Transport GT20, B3970-U Service Engineer’s Manual v1.0
Document part No. D1754-100