The AST2050 chipset is an Integrated Remote Management Processor introduced by ASPEED
Technology Inc. It is a high performance and highly integrated SOC device designed to support various
management functions required for server platforms which require baseboard management, virtual
storage functions, and/or KVM-over-IP functions.
1.2. Key Features
Embedded 200MHz ARM926 32-bit RISC CPU
64MB DDR2-400 SDRAM
8MB SPI Flash
IPMI 2.0 Compliant
KVM over IP
Virtual Media via USB
Web Based User Interface, no additional client software needed, security with SSL(HTTPS)
Monitor and Manage all Envi ronmental Sensors
Notify System Administrato rs wit h Alert: Beep, Warning LE D, SNMP and Email
Sophisticated User Management
Page 3
1.3. IPMI and KVM-over-IP Products
TYAN currently creates 2 different SKUs of the AST2050 product. One is an IPMI only version which
provides full IPMI management. The other is a KVM-over-IP version which includes all the functionality
of the IPMI only version, but also with the added features of KVM-over-IP and virtual storage support.
You would need reference the specification sheet details for each TYAN motherboard in order to pick
the appropriate SKU of product that would contain the level of support necessary for your IPMI
environment.
1.4. Web based GUI
The AST2050 has an embedded web interface which provides a user-friendly Graphics User Interface
(GUI) called the AsterGUI to access all the IPMI features. All you have to do to access the Aster GUI,
is simply enter the IP address of the B
with into your web browser. It is designed to be easy to use and has an easy learning curve because it
uses a standard Internet browser. You can expect to be up and running in only minutes.
aseboard Management Controller (BMC) you wish to interface
Page 4
2. Using the AST2050
The AST2050 allows both local and remote access to the BMC. For local access to the AST2050
chipset users may utilize the local LPC bus through a u tility called KCSFL ASH. Users m ay also ch oose
a IPMI utility of their choice including open source tools such as IPMITool, OpenIPMI, IPMI Util or
TYAN’s UH8 IPMI utility. The UH8.exe utility is available through the TYAN website. The O
S
ystem (OS) must have an IPMI driver installed for local management through the KCS interface to
work. Most modern OS’s have an embedded IPMI driver. If your partic ular OS doesn’t have an
embedded driver, see Section 3 at the end of the manual for further details.
Remote access to the AST2050 is provided by an onboard NIC that is shared with the Intel 82574 chip
via a RMII inter face. Users are able to access the IPMI chipset through th is LAN by entering the
AST2050’s IP address into the address bar of a web browser. Follow the steps outlined in Section 2.1
Network Configuration to configure the NIC prior to use. If you are unsure about which LAN port is
dedicate to the AST2050, please reference the motherboard manual or the TYAN Support Section for
further information about the specifics for your motherboard.
2.1. Network Configuration
By default the AST2050 is set to configure its network interface through a DHCP server. The
AST2050 will try to find a DHCP server during initialization. Once a connection is made, the DHCP
server will provide the AST2050 chip with an IP address, net mask and gateway address. We
recommend assigning the AST2050 a fixed IP address according to its MAC address instead of using
DHCP so that the IPMI IP address does not change between power cycles. The MAC addresses are
printed on white stickers with barcodes near the NICs on all TYAN motherboards.
Regardless of which of the two methods used to obtain the IP address, the IP address will be d isplayed
by the IPMI chipset at the initia l POST d uring the memory count screen once the d evice has finished its
initialization process.
The AST2050 is fully IPMI 2.0 compliant so any IPMI utility may be used to do the LAN configuration.
TYAN provides an IPMI utility that may be used to do this configuration called the UH8. UH8 is the
DOS variant of the tool, UH8L works under Linux and UH8W is the Windows version of the tool. Both of
these UH8 utilities are available on the TYAN website.
perating
Page 5
3. Aster GUI
In the next following sections we will detail each part of the Aster GUI. You will find detailed
information about the System Information, Server Health, Configuration, Remote Control, Maintenance
and Language settings.
3.1. How to Login into the Aster GUI
Any Java and HTTPS Enabled Web browser may be used to access the AST2050 Web GUI. Enter the
IP address of the AST2050 in the address bar and you will be redirected to the login page.
You will be prompted to enter a user name and password. The default user name and password are as
follows:
Note: The default user name and password are in lower-case. When you log in using the root
user name and password you have full administrative powers. It is advised that you change the
root password once you log in.
Field Default
User Name root
Password superuser
Page 6
3.2. System Information Tab
The System Information tab will show the system power on status, firmware revision, release date and
build time.
3.3. Server Heath Tab
The Server Health tab contains options to show the motherboard sensor readings and events. The
S
ensor Data Repository (SDR), Sensor Reading, Sensor Event Log (SEL) and Platform Event Filters
(PEF) are all implemented in compliance with the IPMI2.0 specification.
Page 7
3.3.1 Sensor Reading
This page displays sensor information including readings and status. You can toggle viewing the
thresholds for the sensors by pressing the Show Thresholds button.
Page 8
3.3.2 Event Log
This section show you data related to the servers health, such as sensor readings and the event log.
Page 9
3.4 Configuration Tab
This page contains options to configure Alerts, Mouse mode, Network, SMTP, Users, and Date/Time
NTP Settings.
3.4.1 Alerts
This page allows the user to configure how the BMC handles IPMI alerts. Alert destinations may be set
to allow the system to send notifications when pre-programmed conditions are met. Test alerts may
also be sent from this menu to test the notification settings.
Page 10
Note: When configuring the Alerts setting, please confirm that you have ENABLED Platform Event
Filter (PEF) first in the bios. On some motherboards, the BIOS will disable PEF as the default setting.
You can check it in the BIOS setup or by using UH8 to check if PEF is enabled properly.
3.4.1.1 Modify Alert
The Modify Alert page contains drop down menus and fields to configure alert types (email, SNMP
traps), event severity, destination IP/Email address, and subject etc.
Note: After finished configure Alerts setting, you also should confirm you had configure SMTP mail
server IP. Please refer to Chapter 2.4.5 for further details.
Page 11
3.4.2 Mouse Mode
This configuration is contingent on the OS that is installed on the Local Host and the destination
machine you will manage. Most current Microsoft OS’s (2000, XP, 2003, Vista, 2008) and Mac OS X
use Absolute Mode. Relative mode is used by most Linux distributions (SuSE, RHEL) and older
operating systems like Windows 95/98.
3.4.3 Network
You can view and modify the network settings from this section. You can also select whether to
obtain an IP address either automatically or manually configure one.
Page 12
3.4.4 SMTP
Use this page to configure the IP address for the SMTP Mail server.
3.4.5 Users
Use this page to add, modify, and delete users. You may select “modify user” and then change each
user’s name, password and their associated privileges.
Page 13
3.4.6 Date Time/NTP Settings
Select options to set date/time and Synchronize with the NTP server.
Page 14
3.5 Remote Control
This tab allow s the user to perform various remote operations such as “Console Redirection”, “Power
Control” and “Other Control”.
There are various different SKU’s for your particular motherboard that include various options for IPMI
functions. If you try to use options that are not directly supported by your particular motherboard
version, you will receive various alert messages to let you know that particular feature is not supported
on your version. Here is an example where the IPMI only SKU does not allow access to the
KVM-over-IP feature. The “Java Console” will be grayed out to show that KVM over IP is not an
active feature with this version. You will also receive a pop up window that further explains that this
feature isn’t supported on your particular model.
Page 15
3.5.1 Remote Console Redirection
Press the “Java Console” button to invoke the JVIEWER to start a KVM-over-IP session
3.5.1.1 Java Console - JVIEWER
Once you have started JVIEWER you wind find bar of additional options for use
1) Video - Use JViewer <Video> menu to stop/r estart/exit console redir ect session
Page 16
2) Keyboard - To avoid any problems with special key combination interference, you may need to
use this drop down menu to send special Key combinations to the remote OS.
3) Mouse - Select <Mouse sync> to allow the mouse to work correctly within the JViewer remote
screen (in sync with remote OS). Press <alt-M> to release “mouse sync” and return mouse control to
local OS.
Page 17
4) Options – Select <Options> menu to configure KVM-over-IP Video engine or the bandwidth
settings
5) Device – You can choose from a redirect list of CD-ROM, ISO, Floppy or Floppy Image
Page 18
Choose a local CD-ROM drive to redirect to the remote system.
Note: You will need to configure the “Boot order” on the remote system (via remote station BIOS
Setup, after selecting the CD-ROM to redi rect) before the remote system will boot from the redirected
CD-ROM.
Page 19
3.5.2 Power Controlsand Status
Various options are available on this page to reset power, power off, power on or power cycle the
remote system.
3.5.3 Other Controls
Select options on this page to locate a particular chassis through a LED ID check, clear CMOS and
lock control to the local system through the remote system.
Page 20
3.6 Maintenance
This section allows you to perform main tenance tasks on a remote device.
3.6.1 Firmware Update
Select firmware to upload and then press “update firmware” button to precede with a firmware update.
Page 21
3.6.2 Pre-reserve Configuration
The BMC will verify the firmware version. If a new a firmwa re has be en found , the n a w arning me ssage
will appear to state that an uploaded image is different than the current version.
If you wish to update your firmware, one important step to consider is the Preserve Configuration
check box. Preserve Configuration means that the flash tool will keep the previous configuration (ie.
SDR, FRU, LAN configuration and etc). If the new firmware you are flashing makes changes to some
configuration (ie. sensor threshold or etc.), you should uncheck this box.
Note: If this is the first time you have used the BMC, we aware that there will be no previous
configuration and that will cause you to lose your FRU data and static IP address.
Page 22
3.7 Group Control
The page allows you t o control mult iple BMC’s at the sam e time. The machi ne that you are cur rently
logged into through the AST2050 chip set w ill be named “localhost”. You can then use this screen to g et
Model, Power Status, Sensor, SEL and Front Panel Lockout information for all the other systems that
are connected.
3.7.1 Sensors
Click “Sensors” and you will get the sensor readings of the Host that you choose
Page 23
3.7.2 localhost Event Log
Click “SEL” and you will get the system event logs of the Host that you chose.
3.7.3 Add Host
Click “Add Host” button to add additional host systems.
Page 24
Input BMC IP address, user name and password. The Username and password of new BMC are
shared with localhost by default. Of course, you could type the correct one if different.
Clicking the “Save” button in the ‘add host’ page will give you the following
Page 25
3.7.4 Delete Host
You can use the “Del Host(s)” button to delete any host on the list.
Click the line of host(s) you want to select, click the “Select” button and you will find the “Selected”
value become “Yes”. Only once a host(s) has been selected can it be deleted.
Page 26
If the BMC is malfunctioning or not responding properly, the response column will display a wait. Only
after the system has waited for 30 seconds and attempted another retry, will the display window show
fail
Page 27
4 Section 3.0 SMASH Command Line Protocol in AST2050/Pilot-2
4.0 Quick View
SMASH Command Line Protocol(SMASH CLP) provides server administrators a consistent command
line interface for server monitoring and management tasks. It is a simple and standard way to access
the Pilot-2 BMC.
4.1Enter/Exit of the SMASH CLP Console
Start SMASH Command Li ne Protocol (CLP) console via SSH. Start the SSH client, the user name
and password are same as what was used with the web interface of the Pilot-II.
Page 28
Enter the SMASH-CLP Console
Page 29
Type ->exit to exit SMASH CLP Console
Page 30
4.2 Feature s
4.2.1 System Power Status and Control
Page 31
A user can get the system power status under “system1” by using the following command:
“->cd /system1”
“->show”
A user can use basic terms such as “start”, “stop” and “reset” on through the console by using the
following command:
“->cd /system1”
“->start” or “->stop” or “->reset”
Page 32
4.2.2 Serial Terminal
Under the SMASH-CLP, a user could redirect host serial port 1 to the remote console. A user will need
to make sure that the SOL baud rate configuration matches the host serial port setting.
“->cd /system1/sol1”
‘->start”
Page 33
To exit serial terminal, user ne ed type following keys:
“Enter”+”Esc”+”t”.
4.2.3. Chassis Identification
A user can turn on the chassis ID LED for identification purposes by using the following command:
“->cd /system1”
“->set SysIdentification=Indefinite” (turn ID LED always on)
“->set TimeOutValue=100 SysIdentification=timed” (turn ID LED on for 100s)
“->set SysIdentification=off” (turn off)
Page 34
4.2.4 IPMI Sensors Reading
A users can get sensors readings under “/system1” by using the following command:
“->cd /system1”
“->show”
“->cd sensorX” (X is sensor number)
“->show”
Page 35
4.2.5 IPMI SEL Browse
SEL is under “/system1/sp1/logs1”
“->cd /system1/sp1/logs1”
“->show”
“->cd record1”
“->show”
Page 36
4.2.6 BMC users account configuration
A user can update the user account under “/system1/sp1” by using the follo wing commands:
“->cd /system1/sp1/accountX” (X is account number)
“->set username=xxxx” to change user name
“->set password=xxxx” to change password
“->set enabledstate=1/0” to enable/dis able this account.
Page 37
4.2.7 BMC Network Configuration
A user can change/update the BMC IP Address under “/system1/sp1/enetport1/lanendpt1/ipendpt1” by
using the following command:
“->cd /system1/sp1/enetport1/lanendpt1/ipendpt1”
“->show”
Page 38
User could change IP address, subnet mask or use dhcp. After changing these values, the user will
need to save them by setting property “committed”.
“->set ipaddress=192.168.0.123”
“->set committed=1”
Page 39
Section 5 IPMI OS Drivers and Open Source Software
The AST2050 is designed to operate independently of an operating system and does not require any
additional drivers or software for remote access. The web based Aster interface used for remote
Page 40
access will not allow you to access the IPMI chipset from the local machine. In order to access the
IPMI chipset from the local machine a third party IPMI utility such as IPMI tool must be used. The
AST2050 firmware is fully compliant with the IPMI 2.0 specification which allows the use of standard
IPMI drivers embedded in most current operating systems
.
5.1 Windows IPMI Driver
The AST2050 chipset su pports Intel r eference drivers. They are available direct from Microsoft’s
website. You can go to http://www.intel.com/design/servers/ipmi/tools.htm
Windows Server 2003 R2 and later include an embedded IPMI driver.
for more information.
5.2 Open IPMI Driver on Linux
The AST2050 chipset also supports the Linux open IPMI driver. Use the following commands to load
the IPMI drivers:
“modprobe ipmi_devintf”
“modprobe ipmi_si”
If you use an older version of the Linux kernel, you may need to replace module “ipmi_si” with
“ipmi_kcs”
Note: The S7002 motherboard BIOS encodes IPMI Base IO address at 0xCA2 in its DMI table IPMI
entry so most OS’s embedded IPMI drivers will support the chipset without modification.
5.3 IPMITool and Other Open Source Software
The AST2050 chipset supports open source utilities such as IPMITool, OpenIPMI and IPMI Util.
To establish an IPMITool SOL session the following section of the motherboard’s BIOS must have the
following settings configured:
Advanced > Remote Access Configuration
Serial Port Number: COM 1
Serial Port Mode: 38400, 8, n, 1
6.0 FAQ’s
1. How do I use the IPMI functionality provided by the AST2050 BMC?
Page 41
There is no software to install to use IPMI wi th these motherboards. It is all provided through a web
interface. Refer to the AST2050 manual for complete instructions on how to use this interface.
Simply point your web browser to the IP address of the BMC of the motherboard you want to monitor.
2: How do I find the IP address of the BMC?
The BMC will display its IP address during POST. You will need to know the IP to access the BMC
through another computer on the network. There must either be a static IP address set through UH8
or DHCP must be enabled and the NIC must be plugged into a switch for the BMC to have a valid IP.
Otherwise it will show as 000.000.000.000.
3. Can I access the BMC on the local machine?
The BMC shares a NIC port with the motherboard instead of having a dedicated NIC. The local
machine can’t use this shared NIC to communicate with the BMC. The only way for the local machine
to log into its own BMC to monitor its own temperature sensors for example is for the board to have two
Ethernet cables. The local machine will use the second NIC to communicate with the BMC through
an Ethernet switch or router to the primary NIC that is attached to the BMC.
7.0 Definitions
- IPMI (Intelligent Platform Management Interface) - IPMI is a Management specification used by Intel
for remote management of systems. Below are a couple links that help explain what IPMI is all about.
- BMC (Baseboard Management Controller) – The BMC is the actual chipset that is used for the IPMI
implementation. Below is a link to help further explain what BMC chipsets ar e and how they function:
http://en.wikipedia.org/wiki/Baseboard_Management_Controller
TY AN u ses various b rands/types of BMC chipsets for our SMDC and embedded IPMI solutions. Each
chipset brings with it their own unique set of capabilities that must be integrated into the ov erall IPMI
solution. Simply put, without the BMC chipset, there would be no IPMI ability.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.