TEBQ42R with optional TEGB42SD-B Grill Base shown.
Models: TEBQ30G-B
TEBQ30R-B
TEBQ36G-B
TEBQ36R-B
TEBQ42G-B
TEBQ42R-B
A special message…
Congratulations on your purchase of TWIN EAGLES gas barbecue grill. In
addition to its Unique Style, Superb Performance and High Quality, this grill is built
with pride in the U.S.A. Twin Eagles is committed to making outdoor cooking
products you’ll be proud to own for years.
This manual gives you easy to follow instructions for installing, operating and
maintaining your TWIN EAGLESgrill. We recommend reading this manual
carefully before your first use to insure safety, proper care and operation.
Please record the following information and refer to them when contacting the
company or an authorized service agent. This information is found on the data
nameplate, located on the panel behind the control panel of the grill. Remove the drip
pan to visually access the nameplate from the front of the grill. A second label with
model number and serial number is located under the right side of the control panel.
Model #: ________________________________
Serial #: _________________________________
Date of Purchase: __________________________
Place of Purchase: __________________________
Type of Gas: NG LP
IMPORTANT SAFETY INFORMATION – TWIN EAGLES GAS GRILL
WARNING! Read this manual carefully and completely before using your grill to ensure proper
operation, proper installation, proper servicing and to reduce the risk of fire, burn hazard and/ or
other injury.
FOR YOUR SAFETY
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flames.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your gas
supplier or fire department.
FOR YOUR SAFETY
1. Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
AVERTISSEMENT
S’il y a une odeur de gaz:
1. Coupez l’admission de gaz de l’appariel.
2. Éteindre toute flamme nue.
3. Ouvrir le couvercle.
4. Si l’odeur continue, évite l’appareil et
appelle tout de suite votre fournisseur de gaz
ou les pompiers.
AVERTISSEMENT
1. Ne pas entreposer ni utiliser de l’essence ni
d’autres vapeurs ou liquides inflammables
dans le voisinage de l’appareil, ni de tout
autre appareil.
2. Une bouteille de propane qui n’est pas
raccordée en vue de son utilisation, ne doit
pas être entreposée dans le voisinage de cet
THIS GRILL IS FOR OUTDOOR USE ONLY:
If stored indoors, detach and leave L.P. cylinder
outdoors.
BEFORE LIGHTING
1. Read instructions before lighting.
2. Open lid during lighting.
3. If ignition does not occur in 5 seconds,
turn the burner control(s) off, wait 5
minutes, and repeat the lighting
procedure.
appareil ou de tout autre appareil.
CE GRIL EST POUR UTILISATION à
L’ExTéRIEUR SEULEMENT:
Si l’appareil est entreposé à l’interieur, enlever
les bouteilles et les laisser à l’extérieur.
AVANT D’ALLUMER
L’APPAREIL
1. Lisez les instructions avant d’allumer
l’appareil.
2. Ouvrez le couvercle avant d’allumer l’appareil.
3. Si l’appareil ne s’allume pas en 5 secondes,
fermez le robinet du brûleur, attendez 5
minutes, et procédez de nouveau à l’allumage.
GENERAL SAFETY REQUIREMENTS:
1. The installation of this appliance must conform with local codes or, in the absence of local codes,
either the National Fuel Gas Code, ANZI Z223.1/NFPA 54, or CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code.
2. This outdoor cooking gas appliance is not intended to be installed in or on recreational vehicles
and /or boats.
3. This outdoor cooking gas appliance is intended for use outdoors and shall not be used in a
building, garage or any other enclosed area.
4. Minimum clearance of 12 inches from the back and sides of the grill to adjacent
combustible construction must be maintained. This outdoor cooking gas appliance shall not
be located under overhead-unprotected combustible construction.
5. The utilization of an external electrical source requires that when installed, this outdoor cooking
gas appliance must be electrically grounded in accordance with the local codes or, in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1. Keep any electrical supply cord, or the rotisserie motor cord and the fuel
supply hose away from any heated surfaces.
6. Keep your grill in an area clear and free from combustible materials, gasoline and other
flammable vapors and liquids.
7. DO NOT obstruct the flow of combustion and ventilation air to this appliance. Keep the
ventilation openings of the cylinder enclosure free and clear from debris.
8. Check all gas connections for leaks with soapy water solution and brush. Never use an open
flame. (Reference page 8 for leak test procedure).
9. Check flexible hoses for cuts and wear that may affect the safety before each use.
10. Never use charcoal in the grill.
11. Never use the grill in a windy area.
12. Never use the grill without the drip pan installed and push all the way to the back of the grill.
Without the drip pan, hot grease and debris could leak downward and produce a fire hazard.
13. The pressure regulator and hose assembly supplied with the Twin Eagles Gas Grill must be used.
Replacement pressure regulators and hose assemblies must be those specified by Twin Eagles.
14. CALIFORNIA PROPOSITION 65-WARNING: The burning of gas cooking fuel generates some
by-products which are on the list of substances known by the State of California to cause cancer
or reproductive harm. California law requires businesses to warn customers of potential exposure
to such substances. To minimize exposure to these substances always operate this unit according
to the use and care manual, ensuring you provide good ventilation when cooking with gas.
In Massachusetts: All gas products must be installed using a “Massachusetts” licensed plumber or
gasfitter. A “T” handle type manual gas valve must be installed in the gas supply line to this
appliance. This applies to permanently installed natural gas and propane installations. This does
not apply to propane portable installations using a 20 pound tank.
TABLE OF CONTENTS – TWIN EAGLES GAS GRILL
GETTING STARTED………………………………………………………………………………………..2
GAS REQUIREMENTS
o GAS SAFETY REQUIREMENT………………………………………………..…………...4
o LP GAS HOOKUP………….………………………………………………………..……... 5
o PORTABLE LP CONNECTION………….………………………………………..………. 6
o NATURAL GAS INSTALLATION…………………………………………………..……. 7
o LEAK TEST………………………………………………………………………………….8
ELECTRICAL REQUIREMENTS AND ELECTRICAL DIAGRAM…………………………..………9
WIRING CONNECTION DRAWING DIAGRAM………………………………..………………………10
LOCATING THE GRILL
o CLEARANCE TO COMBUSTIBLE CONSTRUCTION…………………….………..……11
o CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION…………….…………...…..11
CUTOUT DIMENSIONS
o INSULATION JACKET..………………………….…………………………………………12
o GRILL………………………………………………………………………………………...13
ASSEMBLY INSTRUCTIONS
o BRIQUETTE TRAY…………………..………………………………………………….…..14
o SMOKER BOX…………………..……………………………………………………….......14
o WARMING RACK…………………………………………………………………………...14
o ROTISSERIE…………………………...…………………………………………….............15
OPERATING INSTRUCTIONS
o BEFORE LIGHTING THE GRILL…………………………………………………………..16
o TO LIGHT THE GRILL BURNER …………………………………………………….....16
o MATCH LIGHTING INSTRUCTIONS ……..……………………………...........................17
o USING THE GRILL ………………………………………………………………...……….17
o INTERIOR LIGHT OPERATION AND LIGHT BULB REPLACEMENT…………...……17
o USING THE ROTISSERIE BURNER……………..……………………………..………….18
o SEAR ZONE BURNER …………………………....…………………………..…………….18
o SMOKER BOX…………………………………..…………………………….……………..18
CLEANING AND MAINTENANCE
o STAINLESS STEEL………………………………………………………………………….19
o HEX GRATES………………………………………………………………………………...19
o CERAMIC BRIQUETTE TRAY….……………………………………….………………....19
o U-BURNER & SEAR ZONE BURNER…………………………………………..................20
o DRIP PAN & SMOKER BOX………………………………………………………….........20
o SPIDER AND INSECT WARNING………………………………………………………....20
o CORRECT BURNER INSTALLATION.…………………………………………………....21
REPLACEMENT PARTS
o EXPLODED VIEW………………………………………….……………………...……..….22
o REPLACEMENT PARTS LIST……..…………………..……………….……..……….......23
o TROUBLE SHOOTING GUIDE.....……………………………………………..……………24
o LIMITED PRODUCT WARRANTY………………………………………...………..……..25
o WARRANTY REGISTRATION CARD
GETTING STARTED – TWIN EAGLES GAS GRILL
1. Remove all packaging materials, labels and protective plastic film. DO NOT LEAVE UNIT
UNDER THE SUN WITH PROTECTIVE PLASTIC FILM ON FOR A LONG PERIOD OF
TIME AS IT WILL BE DIFFICULT TO REMOVE THE FILM.
2. Check to ensure that all grill accessories listed below are included.
3. Assemble parts as per assembly instructions on page 14-15.
TEBQ
30R
TEBQ
36G
PRE-INSTALLED
TEBQ
36R
TEBQ
42G
TEBQ
42R
4. Fill up the Warranty Registration Card and mail it to the indicated address.
2
5. Get familiar with the knobs and burners identification below.
r
(Opt)
(Op
)
r
(Opt)
(Op
)
r
(Op
)
r
r
(Opt)
TEBQ30 TEBQ36
Grill Burner
Sear Zone
Rotisserie
tional
Grill
Burne
Grill Burner
Sear Zone
Rotisserie
tional
Grill
Burne
Grill
Burne
TEBQ42
Grill Burner
Sear Zone
Rotisserie
tional
Grill
Burne
Grill
Burne
Grill U-Burner (Standard) located
underneath the briquette trays.
Sear Zone Burner (Optional)
usually located on the left side.
Infrared Rotisserie Burner (Optional)
located on the rear panel above the
hex-grates.
3
GAS SAFETY REQUIREMENTS – TWIN EAGLES GAS GRILL
Each appliance is set and tested at the factory for the type of gas supply to be used. Identify
the type of gas, either natural gas or LP gas and make sure that the marking on the data plate
(rating plate) matches the gas being supplied to the grill. The data plate is located on the panel
behind the control panel of the grill. Remove the drip pan to visually access the nameplate label
from the front of the grill. A second label with model number and serial number is located under
the right side of the control panel.
All gas connections should be made by a qualified technician and in accordance with local
codes and ordinances. The installation must conform with local codes or, in the absence of local
codes, with either the national Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/CGA-B149.1,
Natural Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code.
WARNING:
CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN
CONTACT WITH ANY HOT SURFACE OF THE GRILL.
NEVER CONNECT THE GRILL TO AN UNREGULATED GAS SUPPLY.
L.P. GAS (LIQUIFIED PETROLEUM /PROPANE)
If your grill is factory built for L.P., the regulator supplied is set for 11” water column and
is for use with L.P. gas only. The factory-supplied regulator and hose must be used with a 20 lb.
L.P. cylinder.
L.P. GAS SAFETY REQUIREMENT
The LP-gas supply cylinder must be constructed and marked in accordance with the
Specifications for LP-gas Cylinders of the U.S. Department of Transportation (D.O.T.) or the
National Standards of Canada CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods, and Commission, as applicable; and
1. Provided with a listed overfilling prevention device.
2. Provided with a cylinder connection device compatible with the connection for outdoor
cooking appliances.
It must be provided with a shut-off valve terminating in gas tank valve outlet. It must include a
collar to protect the cylinder valve. The cylinder supply system must be arranged for vapor
withdrawal.
Do not operate the gas grill indoors or in any enclosed area. If the gas grill is not in use, the gas
must be turned off at the supply cylinder. If the grill is to be stored indoors, disconnect the gas
supply cylinder and leave the cylinder outdoors.
4
LP GAS HOOK-UP – TWIN EAGLES GAS GRILL
Install the factory-supplied hose and regulator assembly as shown. Connect the
to the grill coupling using a ¾” open wrench. Do not apply pipe sealant to the
regulator to the LP cylinder hand tighten it, do not use a wrench. Check for leaks using soapy water solution.
(Reference page 7 for leak test procedure).
CAUTION: Provide adequate ventilation holes in the enclosure for safety
purposes in the event of a gas leak.
2 ½”
3
/8” flare connection. Connect the
4" MINIMUM CLEARANCE
TO ALLOW LID TO
FULLY OPEN
3
/8” flare end of the hose
Note: An enclosure for LP gas cylinder must be vented on the level of the cylinder valve and at floor
level. The effectiveness of the opening(s) for purposes of ventilation shall be determined with the LP gas
supply cylinder in place. This shall be accomplished by one of the following:
a. One side of the enclosure shall be fully open; or
b. For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings at cylinder valve level shall be provided in the sidewall,
equally sized, spaced at 180 degrees (3.14 rad), and unobstructed. Each opening shall have a
total free area of not less than 1/2 square inch per pound (7.1 cm2/kg) of stored fuel capacity
and not less than a total free area of 10 square inches (64.5 cm2).
Ventilation opening(s) shall be provided at floor level and shall have a total free area of not less
than ½" square inch per pound (7.1 cm2/kg) of stored fuel capacity and not less than a total free area of
10 square inches (64.5 cm2). If ventilation openings at floor level are in a sidewall, there shall be at
least two openings. The bottom of the openings shall be at floor level and the upper edge no more than 5
inches (127 mm) above the floor. The openings shall be equally sized, spaced at 180 degrees (3.14 rad)
and unobstructed.
5
PORTABLE LP CONNECTION – TWIN EAGLES GAS GRILL
One of the many features of the TWIN EAGLES grill base is the pullout slide pan for easy access to
the LP gas tank.
NOTE: Use only a 20-lbs. (5 gallon capacity) gas
cylinder.
WARNING: DO NOT PLACE MORE THAN ONE
CYLINDER IN THE BASE CABINET ENCLOSURE
AT ANY TIME.
WARNING: DO NOT USE A DENTED OR RUSTED
LP CYLINDER.
NEVER USE A CYLINDER WITH A DAMAGED
VALVE.
ALWAYS CHECK FOR LEAKS AFTER
CHANGING THE LP CYLINDER.
THE LP PRESSURE REGULATOR AND HOSE
SUPPLIED WITH THIS UNIT MUST BE USED
WITHOUT ALTERATION.
CAUTION: USE EASY PULL. Use the slot at the
front of the pan to push or pull out the gas cylinder.
Do not place hand on the top of the gas cylinder when
pushing or pulling the slide pan.
EASY PULL
1) To install the gas cylinder, pull out the slide pan and place the cylinder onto the pan.
2) Check to ensure that the tank’s gas valve on top of the cylinder is closed.
3) Connect the LP regulator (included) to the cylinder and hand-tighten only. Open the
tank valve and make sure all connections are leak tight using a soapy water solution
and a brush. (Reference page 7 for leak test procedure).
6
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.