Twin Eagles Premium Grills LP to NG Conversion User Manual

GAS CONVERSION KIT FROM LP TO NG, P/N CKNG-TEBQ
FOR MODELS: TWIN EAGLES GRILLS, TEBQ/TPBQ
1. All gas connections/conversions should be made by a qualified technician and in accordance with local
codes and ordinances.
from the appliance.
3. Insure that you have the Natural Ga s Conversion Kit , as follows: a. P/N 15110-41, Orifice #41, NG , Grill Burner (3 pcs.) b. P/N 15108-50, Orifice #50, Rotis/ Small IR, for TEBQ-30/TPBQ-30, NG (1 pc.) c. P/N 15108-48, Orifice #48, Rotis/ L arge IR, for TEBQ-42/TPBQ-42, NG (1 pc.) d. P/N 15303, Regulator, Natural Gas (1 pc.) e. P/N 18351, Label, Conversion, Gas (1 pc)
4. Replace burner valve orifices. a. Grill Burner:
i. Remove cooking grates
ii. Remove briquette tr ays iii. Remove grill burners iv. Remove grill bur ner orifices, #53 drill size
v. Replace grill burner orifices with #41 drill size vi. Install back the burners, briquette trays & cooking grates. WARNING! IT IS
CRITICAL THAT THE GAS BURNERS ARE PROPERLY INSTALLED
WITH THEIR ORIFICES INSIDE THE BURNERS AIR SHUTTERS. If not properly installed, gas may leak outside of the burner that could lead to fire, potential damage to your grill and bodily injury
b. Infrare d Rotisserie Burner
i. Remove rear hood c over to expose infrared burner gas orif ice
ii. Remove rotis burner orifice, as follows:
1. #57 for TEBQ-30/TPBQ-30
2. #56 for TEBQ-42/TPBQ-42
iii. Replace rotis burner orifice with:
1. Orifice #50 for 30” grill, TEBQ-30/TPBQ-30
2. Orifice #48 for 42” grill, TEBQ-42/TPBQ-42
iv. Replace rear hood cover.
5. Replace LP regulator with the factory supplied NG regulator. a. Disconnect the regulator and hose from the LP-bottle. b. Remove the brass coupling from grill manifold c. Install regulator directly to grill manifold pipe. Make sure that the arrow mark on the regulator
is pointing towards the grill.
d. Check for gas leaks using soapy water solution.
6. NEVER USE THE GRILL WITHOUT FIRST LEAK TESTING THE GAS CONNECTION.
a. Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid soap
and half water.
b. Confirm that all control knobs are in the “OFF” position. c. Turn the main gas valve supply “ON”. d. Apply lea k testing solution by spraying on the pipe joints, fittings, and hose. e. A gas leak is detected if;
i. there is a faint gas smell and/or
ii. growing bubbles appear on any of the connection points and/or hose. DO NOT
attempt to ignite the grill and IMMEDIATELY turn off the gas supply valve.
f. When there is a gas leak, call a qualified service technician. DO NOT use the grill until the leak
is corrected.
7. Calibrate burner low flame setting a. The grill must be hooked up to the gas supply in order to calibrate burner.
b. Turn on burner and set to low. At low setting, all ports of the burner must remain lit. If the
flames are too high or too low, calibrate burner valve.
c. To calibrate burner valve, pull off valve knob. Insert a skinny flat screwdriver into the valve
stem.
d. Turn the adjusting screw inside the stem clockwise to decrease flame or counter clockwise to
increase flame.
e. Perform leak test on the valve stem using the soapy water solution.
8. The conversion is complete. Fill up the Conversion Label. Next, paste it next to the original Serial Plate.
9. The unit is ready for installation. Please refer back to the User’s Manual to insure safety, proper care and
operation.
PN: 18567B 04/11
Loading...