TWIN EAGLES BREAKFAST CLUB
WARNING: BEFORE WORKING ON THIS APPLIANCE DISCONNECT
!
GAS AND ELECTRICAL SUPPLIES.
WARNING: INSTALLATION/GAS CONVERSION MUST BE PERFORMED
!
BY A QUALIFIED TECHNICIAN.
GAS CONVERSION KIT FROM NG TO LP
PN: CKLP-TEBC
FOR MODELS: TEBC / TPBC
IMPORTANT: Retain original proof of purchase to establish warranty period.
Please record the following information and refer to this information when
contacting the company or an authorized service agent. This information is
found on the rating/data plate located on the inside wall of the left side Panel.
Serial No. of Breakfast Club :
________________________________________________________
Date of LP Gas Conversion:
________________________________________________________
LP Gas Conversion by:
________________________________________________________
FOR YOUR RECORDS
P/N:18591B 04/11
1. Check to make sure that you have the LP Gas Conversion Kit as follows:
a. Griddle Plate:
i. PN: 12602, Coupling, 3/8 x ½ FIP (1 pc)
ii. PN 15302, LP Regulator with Hose (1 pc)
iii. PN:15110-55, #55 Orifice Tapered Thread (1 pc)
b. Side Burner:
i. PN 13317, 0.50 (#76 DMS) Orifice Center (2 pcs)
ii. PN: 13318 1.00mm (#61 DMS) Orifice, Outside (2 pcs)
iii. PN: 18351, Label, Conversion, Gas (1 pc)
2. Griddle Plate Conversion
2-1) Remove the grease pan from the front of the Griddle Plate Assembly.
2-2) Remove the screws, located in the front of the Griddle Plate Assembly, as shown.
2-3) Raise the front of Griddle Plate Assembly and make sure the rear portion is resting
on the Griddle Top as shown in the left picture. Pull out the Thermostat Bulb so
that you may remove the Griddle Plate Assembly completely, as shown in the right
picture.
2-4) Unscrew the nut used to hold the U-Burner from the back and remove the U-
Burner.
2-5) Replace the orifices #45, used for NG, and replace it with orifice #55, used for LP.
Use a 1/2" Deep Socket and a Socket Wrench to remove and replace the orifice.
Replace Griddle Plate Assembly when finished and re-install the Thermostat Bulb.
2-6a) For LP Plumbed-In Connection only. The NG regulator is located on the bottom
side of the Breakfast Club. Remove the cap on the regulator then remove the center
black insert and invert it to show the LP marking. Put the cover back. Connect LP gas
line to the regulator directly.
Before (Set for NG) Setting up for LP
2-6b) For LP Tank Connection only. Remove the NG Regulator, located on the bottom
side of the unit. Use a 12” Adjustable Wrench to turn the regulator and a Pipe Wrench to
hold the manifold in place as shown below.
2-7) Install a 3/8 Flare X 1/2 FIP coupling, P/N 12602, by using a 7/8” Open Wrench to
hold the flex tubing and an adjustable wrench for the coupling. Use pipe sealant
approved for LP connection.
2-8) Install the factory supplied LP Hose and Regulator Assembly onto the coupling; do
not use sealant on the flare connection. Use an Adjustable Wrench to tighten the hose.
1