Twin City ES-495 User Manual

Torque Requirements
ES-495
April 1997
SWSI BC/BAF Torque Requirements (in-lb)
FAN NESTED INLET VANES EXTERNAL INLET VANES
SIZE CL 1 CL 2 CL 3 CL 4 CL 1 CL2 CL 3 CL 4 122 N/A N/A N/A N/A 100 100 100 100
135 N/A N/A N/A N/A 100 100 100 110 150 N/A N/A N/A N/A 100 100 100 140 165 100 100 100 130 100 100 130 170 182 100 100 120 160 100 100 150 210 200 100 100 140 190 100 110 180 250 222 100 110 180 240 100 140 230 300 245 100 130 210 290 100 170 280 370 270 100 160 260 350 130 210 340 450 300 120 200 320 430 160 260 410 550 330 150 240 390 520 190 310 500 670 365 180 300 480 640 230 380 610 820 402 220 360 580 770 280 460 750 1000 445 260 440 710 950 340 570 910 1220 490 320 530 860 1150 410 690 1110 1480 542 390 650 1050 1400 510 840 1780 2380 600 480 800 1280 1720 820 1360 2180 2920 660 580 970 1550 2080 990 1640 2640 3530 730 710 1190 2290 3060 1210 2010 3230 4320 807 1050 1750 2800 3750 N/A N/A N/A N/A 890 1280 2120 3410 4550 N/A N/A N/A N/A 982 1550 2590 4150 5550 N/A N/A N/A N/A
DWDI BC/BAF Torque Requirements (in-lb)
FAN NESTED INLET VANES
SIZE CL 1 CL 2 CL 3 CL 4
165 100 120 200 260 182 100 140 240 320 200 100 180 280 380 222 140 220 360 480 245 160 260 420 580 270 200 320 520 700 300 240 400 640 860 330 300 480 780 1040 365 360 600 960 1280 402 440 720 1160 1540 445 520 880 1420 1900 490 640 1060 1720 2300 542 780 1300 2100 2800 600 960 1600 2560 3440 660 1160 1940 3100 4160 730 1420 2380 4580 6120 807 2100 3500 5600 7500 890 2560 4240 6820 9100 982 3100 5180 8300
BCS Torque Requirements (in-lb)
FAN NESTED INLET VANES EXTERNAL INLET VANES
SIZE CL 17 CL 23 CL 26 CL 17 CL 23 CL 26
270 310 520 730 400 670 940 300 380 640 900 500 830 1160 330 460 780 1090 600 1000 1400 365 570 950 1330 730 1230 1720 402 690 1160 1620 890 1490 2740 445 840 1420 1980 1090 2400 3350 490 1020 1720 2400 1320 2910 4070 542 1260 2100 3540 2130 3570 4990 600 1540 3100 4330 2610 4370 6100 660 1860 3750 5240 3150 5280 7380 730 2740 4590 6410 3860 6460 9030 807 3350 5610 7840 N/A N/A N/A 890 4070 6820 9530 N/A N/A N/A 982 4960 8310 N/A N/A N/A
©1997 Twin City Fan Companies, Ltd.
NOTES:
1. Standard length of the handle supplied by Twin City Fan is 10". The force required to operate inlet vane is:
Torque in In-Lb Length of Lever
2. For sizing actuator, multiply above torque by 1.2 for rotary and 1.5 for lin­ear actuators.
RTF/HIB Torque Requirements (in-lb)
FAN NESTED INLET VANES EXTERNAL INLET VANES
SIZE CL 18/20 CL 23/24 CL 18/20 CL 23/24
180 N/A N/A 190 310 200 N/A N/A 230 370 220 N/A N/A 280 460 240 N/A N/A 340 550 270 390 640 410 670 300 480 780 500 820 330 580 950 610 1000 360 710 1170 750 1230 400 870 1430 920 1490 450 1060 1740 1120 1820 490 1290 2120 1360 2920 540 1580 2590 1670 3570 600 1930 3830 2690 4370 660 2810 4630 3250 5290 730 3430 5650 3970 6460 800 4200 6920 4860 7910
NOTES:
1. Standard length of the handle supplied by Twin City Fan is 10". The force required to operate inlet vane is:
Torque in In-Lb Length of Lever
2. For sizing actuator, multiply above torque by 1.2 for rotary and
1.5 for linear actuators.
Industrial Torque Requirements (in-lb)
FAN EXTERNAL INLET VANES
SIZE CL 18/20 CL 23/24 CL 18/20 913 120 170 240
915 170 230 330 917 210 290 420 919 260 360 520 921 320 440 630 923 390 530 760 926 490 680 970 929 620 850 1220 933 800 1100 1580 937 1000 1380 1970 941 1230 1690 3180 945 1480 2680 3840 949 2320 3180 4560 954 2800 3840 5510 960 3470 4750 6810
Twin ciTy fan & blower | www.Tcf.com
5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601
Loading...