Tweco TD-750 User Manual

ARC STARTER
BOX
Used With:
• TD-750 Cutting Systems
• Merlin 3000 Cutting Systems
January 13, 1997
Instruction Manual
Manual No. 0-2475
WARNING
WARNING
Read and understand this entire Instruction Manual and your employer’s safety practices before installing, operating, or servicing the equipment.
While the information contained in this instruction manual represents our best judgement, Thermal Dynamics Corporation assumes no liability for its use.
Thermal Dynamics Arc Starter Box Instruction Manual No. 0-2475
Published by Thermal Dynamics Corporation Industrial Park No. 2 West Lebanon, New Hampshire, USA 03784 (603) 298-5711
Copyright 1995 by Thermal Dynamics Corporation
All rights reserved. Reproduction of this work, in whole or in part, without written
permission of the publisher is prohibited. The publisher does not assume and hereby disclaims any liabil-
ity to any party for any loss or damage caused by errors or omissions in the Arc Starter Box Instruction Manual, whether such errors result from negligence, accident, or any other cause.
Printed in the United States of America
January 13, 1997
TABLE OF CONTENTS
SECTION 1:
GENERAL INFORMATION .................................................................................................. 1
1.01 Notes, Cautions and Warnings ...................................................................... 1
1.02 Important Safety Precautions ........................................................................ 1
1.03 Publications ................................................................................................... 2
1.04 Note, Attention et A v ertissement ................................................................... 3
1.05 Precautions De Securite Importantes ............................................................ 3
1.06 Documents De Reference ............................................................................. 5
1.07 Declaration of Conformity .............................................................................. 6
1.08 Statement of W arr anty ................................................................................... 7
SECTION 2:
INTRODUCTION & DESCRIPTION..................................................................................... 9
2.01 Scope of Manual............................................................................................ 9
2.02 General Description....................................................................................... 9
2.03 Specifications & Design Features .................................................................. 9
SECTION 3:
INSTALLATION PROCEDURES ........................................................................................ 11
3.01 Introduction.................................................................................................. 11
3.02 Site Location................................................................................................ 11
3.03 Unpacking .................................................................................................... 11
3.04 Mounting Arc Starter Box ............................................................................ 11
3.05 Connecting Torch ......................................................................................... 12
3.06 Connecting Torch Leads Extension Assembly ............................................. 12
SECTION 4:
CUSTOMER/OPERATOR SER VICE.................................................................................. 13
4.01 Introduction.................................................................................................. 13
4.02 General Maintenance .................................................................................. 13
4.03 Troubleshooting Guide ................................................................................. 13
4.04 Test Procedures........................................................................................... 15
SECTION 5:
PARTS LISTS.....................................................................................................................19
5.01 Introduction.................................................................................................. 19
5.02 Ordering Information.................................................................................... 19
5.03 Replacement Parts - Box............................................................................. 20
5.04 Replacement Parts - Input/Output Connectors ............................................ 22
5.05 Replacement Parts - Pilot Gas Control ........................................................ 24
APPENDIX I: INTERCONNECTING DIAGRAM......................................................................... 25
APPENDIX II: 24 VAC WIRING BLOCK DIAGRAM FOR MERLIN 3000 PO WER SUPPLY ....... 26
APPENDIX III: MOUNTING HOLE TEMPLATE.......................................................................... 27
SECTION 1:
GENERAL INFORMATION

1.01 Notes, Cautions and Warnings

Throughout this manual, notes, cautions, and warnings are used to highlight important information. These high­lights are categorized as follows:
NOTE
An operation, procedure, or backgr ound informa­tion which requires additional emphasis or is help­ful in efficient operation of the system.
CAUTION
A pr ocedure which, if not properly followed, may cause damage to the equipment.
WARNING
A pr ocedure which, if not properly followed, may cause injury to the operator or others in the oper­ating area.

1.02 Important Safety Precautions

WARNINGS
OPERATION AND MAINTENANCE OF PLASMA ARC EQUIPMENT CAN BE DAN­GEROUS AND HAZARDOUS TO YOUR HEALTH.
Plasma arc cutting produces intense electric and magnetic emissions that may interfere with the proper function of cardiac pacemakers, hearing aids, or other electronic health equipment. Per­sons who work near plasma arc cutting applica­tions should consult their medical health profes­sional and the manufacturer of the health equipment to determine whether a hazard exists.
To prevent possible injury, read, understand and follow all warnings, safety precautions and in­structions before using the equipment. Call 1-603­298-571 1 or your local distributor if you have any questions.
GASES AND FUMES
Gases and fumes produced during the plasma cutting process can be dangerous and hazardous to your health.
Keep all fumes and gases from the breathing area. Keep your head out of the welding fume plume.
Use an air-supplied respirator if ventilation is not adequate to remove all fumes and gases.
The kinds of fumes and gases from the plasma arc depend on the kind of metal being used, coatings on the metal, and the different processes. Y ou must be very careful when cutting or welding any met­als which may contain one or more of the follow­ing:
Antimony Chromium Mercury Arsenic Cobalt Nickel Barium Copper Selenium Beryllium Lead Silver Cadmium Manganese Vanadium
Always r ead the Material Safety Data Sheets (MSDS) that should be supplied with the material you are using. These MSDSs will give you the information regarding the kind and amount of fumes and gases that may be dangerous to your health.
For information on how to test for fumes and gases in your workplace, refer to item 1 in Subsection
1.03, Publications in this manual.
Use special equipment, such as water or down draft cutting tables, to capture fumes and gases.
Do not use the plasma torch in an area where com­bustible or explosive gases or materials are located.
Phosgene, a toxic gas, is generated from the vapors of chlorinated solvents and cleansers. Remove all sources of these vapors.
This product, when used for welding or cutting, produces fumes or gases which contain chemicals known to the State of California to cause birth de­fects and, in some cases, cancer . (California Health & Safety Code Sec. 25249.5 et seq.)
ELECTRIC SHOCK
Electric Shock can injure or kill. The plasma arc process uses and produces high voltage electrical energy. This electric energy can cause severe or fatal shock to the op­erator or others in the workplace.
Never touch any parts that are electrically live orhot.
Date: 10/15/99 1 GENERAL INFORMA TION
W ear dry gloves and clothing. Insulate yourself from the work piece or other parts of the welding cir­cuit.
Repair or replace all worn or damaged parts.
Extra care must be taken when the workplace is
moist or damp.
Install and maintain equipment according to NEC code, refer to item 9 in Subsection 1.03, Publica­tions.
Disconnect power source before performing any ser­vice or repairs.
Read and follow all the instructions in the Operat­ing Manual.
FIRE AND EXPLOSION
Fire and explosion can be caused by hot slag, sparks, or the plasma arc.
Be sure there is no combustible or flammable mate­rial in the workplace. Any material that cannot be removed must be protected.
Ventilate all flammable or explosive vapors from the workplace.
Do not cut or weld on containers that may have held combustibles.
Provide a fire watch when working in an area wher e fire hazards may exist.
Hydrogen gas may be formed and trapped under aluminum workpieces when they are cut under­water or while using a water table. DO NOT cut aluminum alloys underwater or on a water table unless the hydrogen gas can be eliminated or dis­sipated. T rapped hydr ogen gas that is ignited will cause an explosion.
NOISE
Noise can cause permanent hearing loss. Plasma arc pro­cesses can cause noise levels to exceed safe limits. You must protect your ears from loud noise to prevent per­manent loss of hearing.
To protect your hearing from loud noise, wear pro­tective ear plugs and/or ear muffs. Protect others in the workplace.
Noise levels should be measured to be sure the deci­bels (sound) do not exceed safe levels.
For information on how to test for noise, see item 1 in Subsection 1.03, Publications, in this manual.
PLASMA ARC RAYS
Plasma Ar c Rays can injure your eyes and burn your skin. The plasma arc process produces very bright ultra violet and infra red light. These arc rays will damage your eyes and burn your skin if you are not properly pr otected.
To protect your eyes, always wear a welding hel­met or shield. Also always wear safety glasses with side shields, goggles or other protective eye wear.
Wear welding gloves and suitable clothing to pro­tect your skin from the arc rays and sparks.
Keep helmet and safety glasses in good condition. Replace lenses when cracked, chipped or dirty.
Protect others in the work area from the arc rays. Use protective booths, screens or shields.
Use the shade of lens as suggested in the following per ANSI/ASC Z49.1:
Minimum Protective Suggested
Arc Current Shade No. Shade No.
Less Than 300* 8 9
300 - 400* 9 12 400 - 800* 10 14
* These values apply where the actual arc is clearly seen. Experience has shown that lighter filters may be used when the arc is hidden by the work­piece.

1.03 Publications

Refer to the following standards or their latest revisions for more information:
1. OSHA, SAFETY AND HEALTH STANDARDS, 29CFR 1910, obtainable from the Superintendent of Documents, U.S. Government Printing Office, W ash­ington, D.C. 20402
2. ANSI Standard Z49.1, SAFETY IN WELDING AND CUTTING, obtainable from the American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126
3. NIOSH, SAFETY AND HEALTH IN ARC WELD­ING AND GAS WELDING AND CUTTING, obtain­able from the Superintendent of Documents, U.S. Government Printing Office, W ashington, D.C. 20402
4. ANSI Standard Z87.1, SAFE PRACTICES FOR OC­CUP ATION AND EDUCA TIONAL EYE AND FACE PROTECTION, obtainable from American National Standards Institute, 1430 Broadway, New York, NY 10018
5. ANSI Standard Z41.1, STANDARD FOR MEN’S SAFETY-TOE FOOTWEAR, obtainable from the American National Standards Institute, 1430 Broad­way, New York, NY 10018
GENERAL INFORMATION 2 Date 10/15/99
6. ANSI Standard Z49.2, FIRE PREVENTION IN THE USE OF CUTTING AND WELDING PROCESSES, obtainable from American National Standards Insti­tute, 1430 Broadway, New York, NY 10018
7. AWS Standard A6.0, WELDING AND CUTTING CONTAINERS WHICH HAVE HELD COMBUS­TIBLES, obtainable from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126
8. NFPA Standard 51, OXYGEN-FUEL GAS SYSTEMS FOR WELDING, CUTTING AND ALLIED PRO­CESSES, obtainable from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
9. NFP A Standard 70, NA TIONAL ELECTRICAL CODE, obtainable from the National Fire Protection Asso­ciation, Batterymarch Park, Quincy, MA 02269
10. NFPA Standard 51B, CUTTING AND WELDING PROCESSES, obtainable from the National Fire Pro­tection Association, Batterymarch Park, Quincy, MA 02269
11. CGA Pamphlet P-1, SAFE HANDLING OF COM­PRESSED GASES IN CYLINDERS, obtainable from the Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202
12. CSA Standard W117.2, CODE FOR SAFETY IN WELDING AND CUTTING, obtainable from the Ca­nadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3
13. NWSA booklet, WELDING SAFETY BIBLIOGRA­PHY obtainable from the National Welding Supply Association, 1900 Ar ch Street, Philadelphia, PA 19103
14. American Welding Society Standard AWSF4.1, REC­OMMENDED SAFE PRACTICES FOR THE PREP A­RA TION FOR WELDING AND CUTTING OF CON­TAINERS AND PIPING THAT HAVE HELD HAZARDOUS SUBSTANCES, obtainable from the American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126
15. ANSI Standard Z88.2, PRACTICE FOR RESPIRA­TORY PROTECTION, obtainable from American National Standards Institute, 1430 Broadway, New York, NY 10018

1.04 Note, Attention et Avertissement

ATTENTION
Toute procédure pouvant résulter l’endommagement du matériel en cas de non­respect de la procédur e en question.
AVERTISSEMENT
Toute procédure pouvant provoquer des blessures de l’opérateur ou des autres personnes se trouvant dans la zone de travail en cas de non-respect de la procédure en question.

1.05 Precautions De Securite Importantes

AVERTISSEMENTS
L’OPÉRATION ET LA MAINTENANCE DU MATÉRIEL DE SOUDAGE À L’ARC AU JET DE PLASMA PEUVENT PRÉSENTER DES RISQUES ET DES DANGERS DE SANTÉ.
Coupant à l’arc au jet de plasma produit de l’énergie électrique haute tension et des émissions magnétique qui peuvent interférer la fonction propre d’un “pacemaker” cardiaque, les appareils auditif, ou autre matériel de santé electronique. Ceux qui travail près d’une application à l’arc au jet de plasma devrait consulter leur membre professionel de médication et le manufacturier de matériel de santé pour déterminer s’il existe des risques de santé.
Il faut communiquer aux opérateurs et au person­nel TOUS les dangers possibles. Afin d’éviter les blessures possibles, lisez, comprenez et suivez tous les avertissements, toutes les précautions de sécurité et toutes les consignes avant d’utiliser le matériel. Composez le + 603-298-571 1 ou votre distributeur local si vous avez des questions.
Dans ce manuel, les mots note,attention, etavertissement sont utilisés pour mettre en relief des
FUMÉE et GAZ
informations à caractère important. Ces mises en relief sont classifiées comme suit :
La fumée et les gaz produits par le procédé de jet de
NOTE
Toute opération, procédure ou renseignement
plasma peuvent présenter des risques et des dangers de santé.
général sur lequel il importe d’insister davantage ou qui contribue à l’efficacité de fonctionnement du système.
Date: 10/15/99 3 GENERAL INFORMA TION
Eloignez toute fumée et gaz de votre zone de respi­ration. Gardez votre tête hors de la plume de fumée provenant du chalumeau.
Utilisez un appareil respiratoire à alimentation en air si l’aération fournie ne permet pas d’éliminer la fumée et les gaz.
Les sortes de gaz et de fumée provenant de larc de plasma dépendent du genre de métal utilisé, des revêtements se trouvant sur le métal et des différents procédés. Vous devez prendre soin lorsque vous coupez ou soudez tout métal pouvant contenir un ou plusieurs des éléments suivants:
antimoine cadmium mercure argent chrome nickel arsenic cobalt plomb baryum cuivre sélénium béryllium manganèse vanadium
Ne touchez jamais une pièce sous tension ouvive; portez des gants et des vêtements secs.
Isolez-vous de la pièce de travail ou des autres par­ties du circuit de soudage.
Réparez ou remplacez toute pièce usée ou endommagée.
Prenez des soins particuliers lorsque la zone de tra­vail est humide ou moite.
Montez et maintenez le matériel conformément au Code électrique national des Etats-Unis. (Voir la page 5, article 9.)
Débranchez lalimentation électrique avant tout tra­vail dentretien ou de réparation.
Lisez et respectez toutes les consignes du Manuel de consignes.
Lisez toujours les fiches de données sur la sécurité des matières (sigle américain MSDS); celles-ci devraient être fournies avec le matériel que vous utilisez. Les MSDS contiennent des renseignements quant à la quantité et la nature de la fumée et des gaz pouvant poser des dangers de santé.
Pour des informations sur la manière de tester la fumée et les gaz de votre lieu de travail, consultez l
article 1 et les documents cités à la page 5.
Utilisez un équipement spécial tel que des tables de
coupe à débit deau ou à courant descendant pour capter la fumée et les gaz.
Nutilisez pas le chalumeau au jet de plasma dans une zone où se trouvent des matières ou des gaz combustibles ou explosifs.
Le phosgène, un gaz toxique, est généré par la fumée provenant des solvants et des produits de nettoyage chlorés. Eliminez toute source de telle fumée.
Ce produit, dans le procéder de soudage et de coupe, produit de la fumée ou des gaz pouvant contenir des éléments reconnu dans L’ état de la Californie, qui peuvent causer des défauts de naissance et le cancer . (La sécurité de santé en Californie et la code sécurité Sec. 25249.5 et seq.)
CHOC ELECTRIQUE
INCENDIE ET EXPLOSION
Les incendies et les explosions peuvent résulter des scories chaudes, des étincelles ou de l’arc de plasma. Le procédé à l’arc de plasma produit du métal, des étincelles, des scories chaudes pouvant mettre le feu aux matières com­bustibles ou provoquer lexplosion de fumées inflammables.
Soyez certain quaucune matière combustible ou in­flammable ne se trouve sur le lieu de travail. Protégez toute telle matière quil est impossible de retirer de la zone de travail.
Procurez une bonne aération de toutes les fumées inflammables ou explosives.
Ne coupez pas et ne soudez pas les conteneurs ayant pu renfermer des matières combustibles.
Prévoyez une veille dincendie lors de tout travail dans une zone présentant des dangers dincendie.
Le gas hydrogène peut se former ou saccumuler sous les pièces de travail en aluminium lorsquelles sont coupées sous leau ou sur une table deau. NE P AS couper les alliages en aluminium sous leau ou sur une table deau à moins que le gas hydrogène peut s’échapper ou se dissiper. Le gas hydrogène accumulé explosera si enflammé.
RAYONS DARC DE PLASMA
Les chocs électriques peuvent blesser ou même tuer. Le procédé au jet de plasma requiert et produit de l’énergie électrique haute tension. Cette énergie électrique peut produire des chocs graves, voire mortels, pour l’opérateur et les autres personnes sur le lieu de travail.
GENERAL INFORMATION 4 Date 10/15/99
Les rayons provenant de l’arc de plasma peuvent blesser vos yeux et brûler votre peau. Le procédé à l’arc de plasma produit une lumière infra-rouge et des rayons ultra-vio­lets très forts. Ces rayons darc nuiront à vos yeux et brûleront votre peau si vous ne vous protégez pas correctement.
Pour protéger vos yeux, portez toujours un casque ou un écran de soudeur . Portez toujours des lunettes de sécurité munies de parois latérales ou des lu­nettes de protection ou une autre sorte de protec­tion oculaire.
Portez des gants de soudeur et un vêtement protecteur approprié pour protéger votre peau contre les étincelles et les rayons de l’arc.
Maintenez votre casque et vos lunettes de protec­tion en bon état. Remplacez toute lentille sale ou comportant fissure ou rognure.
Protégez les autres personnes se trouvant sur la zone de travail contre les rayons de larc en fournissant des cabines ou des écrans de protection.
Utilisez la nuance de lentille qui est suggèrée dans le recommendation qui suivent ANSI/ASC Z49.1:
Nuance Minimum Nuance Suggerée
Courant Arc Protective Numéro Numéro
Moins de 300* 8 9
300 - 400* 9 12 400 - 800* 10 14
* Ces valeurs s’appliquent ou l’arc actuel est observé clairement. L ’experience a démontrer que les filtres moins foncés peuvent être utilisés quand l’arc est caché par moiceau de travail.
BRUIT
Le bruit peut provoquer une perte permanente de l’ouïe. Les procédés de soudage à l’arc de plasma peuvent provoquer des niveaux sonores supérieurs aux limites normalement acceptables. Vous dú4ez vous protéger les oreilles contre les bruits forts afin d’éviter une perte permanente de louïe.
Pour protéger votre ouïe contre les bruits forts, portez des tampons protecteurs et/ou des protections auriculaires. Protégez également les autres personnes se trouvant sur le lieu de travail.
Il faut mesurer les niveaux sonores afin dassurer que les décibels (le bruit) ne dépassent pas les niveaux sûrs.
Pour des renseignements sur la manière de tester le bruit, consultez larticle 1, page 5.

1.06 Documents De Reference

Consultez les normes suivantes ou les révisions les plus récentes ayant été faites à celles-ci pour de plus amples renseignements :
1. OSHA, NORMES DE SÉCURITÉ DU TRAVAIL ET DE PROTECTION DE LA SANTÉ, 29CFR 1910, disponible auprès du Superintendent of Docu­ments, U.S. Government Printing Office, Washing­ton, D.C. 20402
2. Norme ANSI Z49.1, LA SÉCURITÉ DES OPÉRATIONS DE COUPE ET DE SOUDAGE, disponible auprès de la Société Américaine de Soudage (American Welding Society), 550 N.W. LeJeune Rd., Miami, FL 33126
3. NIOSH, LA SÉCURITÉ ET LA SANTÉ LORS DES OPÉRATIONS DE COUPE ET DE SOUDAGE À L’ARC ET AU GAZ, disponible auprès du Superin- tendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402
4. Norme ANSI Z87.1, PRATIQUES SURES POUR LA PROTECTION DES YEUX ET DU VISAGE AU TRAVAIL ET DANS LES ECOLES, disponible de lInstitut Américain des Normes Nationales (Ameri­can National Standards Institute), 1430 Broadway, New York, NY 10018
5. Norme ANSI Z41.1, NORMES POUR LES CHAUSSURES PROTECTRICES, disponible auprès de lAmerican National Standards Institute, 1430 Broadway, New York, NY 10018
6. Norme ANSI Z49.2, PRÉVENTION DES INCENDIES LORS DE L’EMPLOI DE PROCÉDÉS DE COUPE ET DE SOUDAGE, disponible auprès de lAmerican National Standards Institute, 1430 Broadway, New York, NY 10018
7. Norme A6.0 de lAssociation Américaine du Soudage (A WS), LE SOUDAGE ET LA COUPE DE CONTENEURS AYANT RENFERMÉ DES PRODUITS COMBUSTIBLES, disponible auprès de la American Welding Society , 550 N.W . LeJeune Rd., Miami, FL 33126
8. Norme 51 de lAssociation Américaine pour la Pro­tection contre les Incendies (NFP A), LES SYSTEMES À GAZ AVEC ALIMENTATION EN OXYGENE POUR LE SOUDAGE, LA COUPE ET LES PROCÉDÉS ASSOCIÉS, disponible auprès de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
9. Norme 70 de la NFPA, CODE ELECTRIQUE NA­TIONAL, disponible auprès de la National Fire Pro­tection Association, Batterymarch Park, Quincy, MA 02269
10. Norme 51B de la NFPA, LES PROCÉDÉS DE COUPE ET DE SOUDAGE, disponible auprès de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
Date: 10/15/99 5 GENERAL INFORMA TION
1 1. Brochure GCA P-1, LA MANIPULATION SANS
RISQUE DES GAZ COMPRIMÉS EN CYLINDRES, disponible auprès de l’Association des Gaz Comprimés (Compressed Gas Associa­tion), 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202
12. Norme CSA W117.2, CODE DE SÉCURITÉ POUR LE SOUDAGE ET LA COUPE, disponible auprès de lAssociation des Normes Canadiennes, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada, M9W 1R3
13. ivret NWSA, BIBLIOGRAPHIE SUR LA SÉCURITÉ DU SOUDAGE, disponible auprès de lAssociation Nationale de Fournitures de Soudage (National W elding Supply Association), 1900 Arch Street, Philadelphia, PA 19103
14. Norme A WSF4.1 de lAssociation Américaine de Soudage, RECOMMANDATIONS DE PRA­TIQUES SURES POUR LA PRÉPARATION À LA COUPE ET AU SOUDAGE DE CONTENEURS ET TUYAUX AYANT RENFERMÉ DES PRODUITS DANGEREUX , disponible auprès de la American Welding Society, 550 N.W. LeJeune Rd., Miami, FL 33126
15. Norme ANSI Z88.2, PRATIQUES DE PROTEC­TION RESPIRATOIRE, disponible auprès de lAmerican National Standards Institute, 1430 Broadway, New York, NY 10018
GENERAL INFORMATION 6 Date 10/15/99