(Optional) Depending on installation requirements: At
mounted using appropriate brackets and hardware.
via the DB9 IOIO or AUX I/O connectors, as needed.
MultiView™ II AK600 Receiver: Quick Start Guide
The Magenta MultiView™ II AK600 receiver extends a video, audio, and serial signals over standard CAT5 cable
(also CAT5e and CAT6). There are user-configurable settings for video, audio, and serial options which can be
controlled from the front panel. For more details please refer to the complete MultiView™ II AK600 User Guide,
available for download at www.magenta-research.com, or scan the QR-code shown here to access the user guide directly:
Required Tools / Hardware / Materials: Tools include appropriate screwdriver(s) and mounting hardware
(optional, for example: rack-mount, wall or under-desk mounting). Required materials include appropriate cables for
your specific application.
PRECAUTIONS: (1) Do not apply AC power until instructed to
do so. (2) This equipment is not intended for, nor does it
support, distribution through an Ethernet network. Do not
connect these devices to any sort of networking or
telecommunications equipment! (3) Use only Magenta
Research LTD approved MultiView™ II power adapters. Failure
to do so may damage this device and will void the warranty.
Connect the VGA OUT
(HD15 connector) to the
Connect the CAT5 cable
(Optional) Connect the
output CAT5 cable via the
any time during installation, the receiver may be securely
(Optional) Make your serial and/or audio connections
Receiver Rear View
Connect the DC power cable
(+5VDC @ 3A. max) to the POWER
Off = norm
On = Config mode-1
Receiver Front View
Power-up Check: After all signal and power cables are connected, then apply AC power. The power-on indicator should light. If
there is a local monitor attached, a video image should appear on the monitor. If there is no image on the display, recheck all cables
and ensure the display is turned on. Also check that the EQ is properly set – this is most often the case when there is no display image.
Front Panel Controls: (Refer to Figure-2) There are four buttons (CFG/MODE, SKEW/SEL, DOWN and UP), and several green
LED status indicators. These are used to control the operating modes of the receiver, and to display current status.
Status Indicators at power-up: When the MVII-AK600 is first powered on, the status indicators will cycle through a test sequence,
then display the current EQ setting on LEDs 1-8. This is the “normal” mode of operation:
POWER-ON indicator is on.
CFG indicator is off.
SKEW/RGB indicator is off.
EQ/SQEW indicators display current EQ settings (0 to 100%).
As previously noted, it is critical that the EQ setting be adjusted to compensate for the length of CAT5 cable leading back to the
transmitter. Skew compensation adjustment (if your MVII-AK600 is equipped with an AkuComp-II module) will also be important for best
image quality.
© 1998-2012 by Magenta Research, LTD., All rights reserved. Magenta Research, LTD, 128 Litchfield Road New Milford, CT 06776 USA
USA: (800) 805-0944 INT: (+1) 860-210-0546 www.magenta-research.com
Document # 5310269-01 Rev-01 (10/8/2012) Page 1 of 4
EQ Adjustment: When the MVII-AK600 is operating in normal mode (CFG indicator is off), it is possible to quickly adjust the EQ. The
The MVII-AK600 will auto-detect the required RepliSync-I mode (“normal” or
“stretched”). This is the factory-default setting.
Force RepliSync-II mode. This is compatible with MultiView II “RepliSync-II” mode
only (when connected to a MultiView-II transmitter).
Force fixed-sync mode. NOTE: The source MultiView transmitter must also be in
fixed-sync mode. Note that H/V polarity settings must also be selected at each
receiver.
EQ/SKEW indicators 1-8 will change accordingly to show 0 to 100% of the adjustment range.
(starting in normal-mode)
Press and hold the UP or DOWN button until the SKEW/RGB indicator turns on (VIOLET). Release the UP or DOWN button.
Press the UP or DOWN buttons repeatedly to adjust the EQ setting, either one step at a time or hold for auto-repeat.
To exit EQ-ADJUST mode, leave the buttons untouched for 10 seconds, or press the CFG button once.
Note: For best results, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the Magenta website.
Skew Adjustment: If the AkuComp-II skew module is installed, it is possible to quickly adjust the RGB values when the AK600 is
operating in normal mode. The EQ/SKEW indicators 1-8 will show the current setting as 0-100% of the SKEW adjustment range.
(starting in normal-mode)
RED skew adjust: Press and hold the SKEW/SEL button until the SKEW/RGB indicator turns on RED. Release the SKEW
button.
Press the UP or DOWN button repeatedly to adjust the RED skew value.
GREEN skew adjust: Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn GREEN.
Press the UP or DOWN button repeatedly to adjust the GREEN value.
BLUE skew adjust: Press and release the SKEW/SEL button. The SKEW/RGB indicator will turn BLUE.
Press the UP or DOWN button to adjust the BLUE value.
Pressing the SKEW/SEL button again will return you to step-2, allowing adjustment of the RED skew again.
To exit SKEW-ADJUST mode, leave the buttons untouched for 10 seconds or press the CFG button.
Note: For best results, use the Magenta EQ/Skew “test pattern” image if possible. This is available from the Magenta website.
Changing Internal Settings: In configuration-mode (CFG indicator = on or flashing), the CFG and SKEW/SEL buttons, plus the
LED indicators (1-8) will allow you to change internal configuration settings. The changes are effective immediately and are saved in
non-volatile memory.
To enter configuration-mode: Press and hold the CFG button until the CFG indicator is ON. Once in this mode, LEDs 1-8
will display the current settings as described in the tables below. You are now at configuration menu level-1.
To exit configuration-mode: Leave the buttons untouched for 10 seconds or press the CFG button again. The CFG indicator
will turn off (normal-mode).
Note: There are two configuration modes. CFG(on) = Mode-1, CFG(flashing) = Mode-2.
Configuration (mode-1), Sync-mode Options: The MVII-AK600 is factory-configured for auto-detecting the proper sync-mode
(RepliSync-I normal/stretched). This mode is generally compatible with all existing MultiView transmitter and receiver products that
support RepliSync (if they are also using their default settings). However, some video sources may require a custom sync-mode setting
(especially at 1080p and 1920x1200 video resolutions). For these cases, one of the other sync-modes can be selected. Note that any
connected MultiView device (transmitter or daisy-chained receiver) MAY also require a change to its sync-mode settings. Otherwise,
you may not get a proper video display output at one or more receivers.
(starting in normal-mode)
Press and hold the CFG button until the CFG indictor is ON. Release the CFG button.
o LEDs 1-8 will show the current value for all Mode-1 configuration settings as bright (same as ON), dim (same as OFF).
Press and release the SKEW/SEL button once.
LED indicators 1 and 2 should be illuminated (either ON or DIM); all others (indicators 3-8) should be off.
Press the UP and DOWN buttons to step through the available sync-mode settings as shown below.
To leave configuration-mode, leave the buttons untouched for 10 seconds or press the CFG button.
Note: There is no CFG1 parameter for LED3.
© 1998-2012 by Magenta Research, LTD., All rights reserved. Magenta Research, LTD, 128 Litchfield Road New Milford, CT 06776 USA
USA: (800) 805-0944 INT: (+1) 860-210-0546 www.magenta-research.com
Document # 5310269-01 Rev-01 (10/8/2012) Page 2 of 4