Tvone 1T-CL-322-EU, 1T-CL-322-US Instruction Manual

Page | 1
Instruction Manual
1T-CL-322-EU
15 Button Wall Plate Control Keypad
1T-CL-322-US
16 Button Wall Plate Control Keypad
1T-CL-322
1T-CL-322
Page | 2
Table of Contents
Liability Statement ................................................................... 4
Safety Precautions ................................................................... 5
Introduction ............................................................................. 5
Requirements .......................................................................... 6
Package Contents .................................................................... 6
Features ................................................................................... 6
Operation Controls and Functions ........................................... 7
Front and Rear Panel ........................................................... 7
Telnet Commands ................................................................ 8
Software Application ......................................................... 10
Telnet Control .................................................................... 11
WebGUI Control................................................................. 12
Macro Settings ................................................................... 13
Extension Macros .............................................................. 16
Command Settings ............................................................. 17
Command List .................................................................... 18
Schedule ............................................................................ 20
Network Settings ............................................................... 21
System Settings .................................................................. 22
System Time ....................................................................... 23
Sample Application Diagram ................................................. 24
Sample Ethernet Commands ................................................. 24
Button Labels ......................................................................... 25
Page | 3
Updating Firmware ................................................................ 26
Specifications ......................................................................... 27
Acronyms ............................................................................... 27
Limited Warranty ................................................................... 28
Regulatory Compliance .......................................................... 29
Contact Information .............................................................. 30
Page | 4
Liability Statement
This product is intended for professional use. This product is not intended for use in a medical environment and does not have the required certifications for such use. Similarly, use aboard any aircraft or spacecraft while in flight or as an adjunct to any surface, airborne or marine navigation system or any offshore marine activity, including control of any watercraft, or any use similar to those specifically herein mentioned is prohibited. Use in the aforementioned circumstances would require additional testing and certification.
No warranty is made either expressed or implied including but not limited to any implied warranties of merchantability or fitness for a particular purpose. In no event shall the supplier or manufacturer of this product be liable for errors found within, or be liable for any direct, indirect or consequential damages or loss in connection with the purchase or use of this hardware, software or manual. The sole and exclusive liability to the supplier and manufacturer regardless of the form of action shall not exceed the replacement cost of the materials described herein.
tvONE reserves the right to revise any of its hardware and software products following its policy to modify and/or improve its products where necessary or desirable. This statement does not affect the legal rights of the user in any way.
By using this equipment you have indicated that you have agreed to the terms listed above. If you do not wish to agree or the above terms are contrary to your conditions of purchase you may return the equipment, unused, to your supplier.
All third party trademarks and copyrights are recognized. The tvONE logo, Magenta logo, CORIO word and the CORIO logo are registered trademarks of tvONE. All other trademarks are the property of their respective holders.
E&OE
Page | 5
Safety Precautions
Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply.
Please keep the following in mind as you unpack and install this equipment:
Always follow basic safety precautions to reduce the risk of
fire, electrical shock and injury to persons.
To prevent fire or shock hazard, do not expose the unit to
rain, moisture or install this product near water.
Never spill liquid of any kind on or into this product. Never push an object of any kind into this product through
any openings or empty slots in the unit, as you may damage parts inside the unit.
Do not attach the power supply cabling to building surfaces. Use only the supplied power supply unit (PSU). Do not use
the PSU if it is damaged.
Do not allow anything to rest on the power cabling or allow
any weight to be placed upon it or any person walk on it.
To protect the unit from overheating, do not block any vents
or openings in the unit housing that provide ventilation and allow for sufficient space for air to circulate around the unit.
Introduction
The 1T-CL-322 Control Panel is designed for system installers to control devices through an Ethernet connection and Relay output(s) capable of supporting DC 0-24V/8A. The EU version has 15 direct macro command buttons, the US version has 16. There are an extra 15 or 16 ‘Extended macro commands available through the WebGUI control. Each Extended macro allows an additional 16 commands to be executed within one push. A total of 128 commands can be stored in the unit, each command can be up to 128 characters in length. Each button offers red and blue LED backlight to create various color themes or to show
Page | 6
activation of a command. The controller has PoE (Power over Ethernet) functionality to power the unit and a dc power supply is also included. Commands can be scheduled by time or date using the internal clock and calendar functions within your programming.
Requirements
Active Ethernet connection from switch or router.
Power to the unit via either Power over Ethernet (PoE) or using the supplied DC power supply.
Package Contents
Wall Plate Control Keypad USB Type A to Mini USB OTG Connector 3.5mm Terminal Block (2x EU and 1x US models) 5 Volt / 2.6 Amp DC Power Adaptor Pre-Printed Button Label Stickers Operation Manual
Features
15 or 16 macro buttons (depending on regional version) with
15 or 16 virtual buttons through WebUI with up to 16 commands per macro, 128 commands stored on the control system
Relay(s) to control other devices supports DC 0-24V/8A Scheduling control system and settings Can be controlled by Key Pad, Telnet and WebGUI Supports PoE function or DC power supply selection
Page | 7
Operation Controls and Functions
Front and Rear Panel
EU version US version
Macro Buttons: Each button can support up to 16 commands and has 2 LEDs, one red and one blue, adjustable from 0 to 100%. (For further detail on settings please refer to the WebGUI Control section)
Ethernet: Connect to an active Ethernet connection, or direct to a PC or Laptop. This connection supports PoE when connected to an Ethernet switch that supports 48v PoE. The unit can be powered without the external 5 volt DC power supply.
DC 5V: Plug in the 5V DC power adaptor (included) and connect to AC wall outlet. Please note, this not necessary if using PoE.
Relay out: Connect to a device that requires 0 to 24V/8A DC power via a relay or contact closure switch.
1T-CL-322
1T-CL-322
Page | 8
Telnet Commands
COMMAND
DESCRIPTION
PARAMETER
IPCONFIG
Display the current IP configuration
NONE
SIPMODE
Set Ethernet IP mode
N = STATIC/DHCP
SIPADDR XXX. XXX.XXX.XXX
Set Ethernet IP address
XXX = 0 to 255
SNETMASK XXX. XXX.XXX.XXX
Set Ethernet Subnet mask
XXX = 0 to 255
SGATEWAY XXX. XXX.XXX.XXX
Set Ethernet gateway
XXX = 0 to 255
VER
Show unit firmware version
NONE
FADEFAULT
All configurations set to factory default
NONE
ETH_FADEFAULT
All Ethernet configurations set to factory default*
NONE
REBOOT
System reboot
NONE
HELP (?)
Show command list
NONE
HELP N
Show description of command
N = COMMAND NAME
RELAY N N1
Relay control
N = PORT (1 or 2) N1 = OPEN/CLOSE/
TOGGLE
LEDBLUE N N1
LED blue backlight control
N = BUTTON (1-15/16)
N1 = % (0-100)
LEDRED N N1
LED red backlight control
N = BUTTON (1-15/16)
N1 = % (0-100)
Page | 9
COMMAND
DESCRIPTION
PARAMETER
LEDBLUES N
All blue LED backlight control
N = % (0-100)
LEDREDS N
All red LED backlight control
N = % (0-100)
LEDSHOW N
LED dimming mode control
N = ON/OFF/TOGGLE
BACKLIGHT N
All LED backlight control
N = % (0-100)
KEY_PRESS N RELEASE
Key press trigger type (Press and RELEASE)
(Default)
N = PORT NUMBER
KEY_PRESS N HOLD
Key press trigger type (Press and HOLD)
N = PORT NUMBER
MACRO RUN N
Run specific Macro **
N = MACRO ID (1-30/32)
MACRO STOP
Stop Macro
NONE
MACRO STOP
Stop specific Macro
N = MACRO ID (1-30/32)
@MACRO_FA DEFAULT
All Macro control set to factory default***
NONE
Note:
All commands require carriage return at the end of the command string. Commands are case-insensitive.
*Command resets IP address and login ID & password back to factory default.
**Extended Macros are 16-30 on the EU version and 17-32 on the US version.
***Command resets macro 1 through 6 to factory default and deletes macros 7 through 30.
Loading...
+ 21 hidden pages