TVILIGHT TVI-GW-1 Series, Gateway 3.1 Installation Manual

English
Gateway
3.1
Installation Manual
Page 2 of 14
Version Author Date Changes Approved by
Idiondo
30/082017 Initial version of the
document
Henri Eskonen
v2 Henri Eskonen 22/12/2017 Minor formatting
Idiondo and Henri Eskonen
07/06/2018 Merging grommet
and clable gland versions; add Appendix for Ethernet connection; minor formatting
v3 - 07/06/2018
TVILIGHT BV / Rozenburglaan 3, 9727 DL, Groningen, the Netherlands NL+31 (0)50 800 3240 / info@tvilight.com / www.tvilight.com
Page 3 of 14
In box:
M16 Cable Gland
Pole ID Label
You’ll need:
M16 Threaded
OR
20 mm
Generic Strap x 2
Max = 13mm
Min = 8mm
5.5m Cable
Gateway v3.1
OR
20 mm Rubber Grommet
Drill
Page 4 of 14
1. Run wire through Cable Gland/Grommet
2. Drill hole into the pole:
- M16 threaded (Cable Gland) OR
- 20 mm (Grommet)
5m
Note: For added protection against rust, the use of an anti-corrosion spray such as
WD40 Corrosion inhibitor or equal is recommended.
OR
Page 5 of 14
3. Run wire through hole in the pole
4. Insert Cable Gland/Grommet into hole in the pole
OR
OR
Loading...