![](/html/03/039f/039f0dbdefe164b7da8140df4c6c33efa58c1d7a04c54d88ff06ecfdbd049977/bg2.png)
Page 2 of 10
Version Author Date Changes Approved by
v4 Henri Eskonen 21/12/2017 Added version
control page. Minor
formatting.
v4 - 21/12/2017
TVILIGHT BV / Westerhaven 13, 9718 AW Groningen, the Netherlands
+31 (0)50 800 3240 / info@tvilight.com / www.tvilight.com
![](/html/03/039f/039f0dbdefe164b7da8140df4c6c33efa58c1d7a04c54d88ff06ecfdbd049977/bg3.png)
Page 3 of 10
In order to function properly, CitySense Plus must be
connected to a dimmable driver/ballast.
NOTE: Some dimmable drivers/ballasts must be
programmed/set to dimmable mode. If this has not been
done, CitySense Plus will not be able to dim the connected
armature.
ATTENTION:
![](/html/03/039f/039f0dbdefe164b7da8140df4c6c33efa58c1d7a04c54d88ff06ecfdbd049977/bg5.png)
Page 5 of 10
1. Push cable gland through wire
2. Drill M16 threaded hole into pole
5m
Note: for added protection against rust, the use of an anti-corrosion
spray such as WD40 Corrosion inhibitor or equal is recommended.
![](/html/03/039f/039f0dbdefe164b7da8140df4c6c33efa58c1d7a04c54d88ff06ecfdbd049977/bg6.png)
Page 6 of 10
3. Run wire through hole
4. Screw cable gland in hole
Rotate the cable gland to tighten
Twist the end leads
of the wires
![](/html/03/039f/039f0dbdefe164b7da8140df4c6c33efa58c1d7a04c54d88ff06ecfdbd049977/bg7.png)
Page 7 of 10
5. Strap product to pole
6. Level the product
* Ensure Tensioning Tool is set
to maximum tension (#4)
Tensioning Tool
Position 2: Standard
1
2
3