TVH Safe-T-Lock Operation Instructions Manual

OPERATION INSTRUCTIONS
Read and Save
Safe-T-Lock 1
WARRANTY
• The Safe-T-Lock™ is a sealed unit. Removing or tampering with the epoxy encapsulant will void the warranty.
• Units damaged due to overload, abuse or incorrect installation will not be accepted in warranty.
This product is warranted against defects in materials or workmanship for two years from the date of purchase. Should service be required, the customer should return the product for warranty considera­tion. All products requiring warranty service shall be returned within two years from the date of purchase. Exclusions from this warranty are the fi nish, and damage caused by improper installation or use.
The manufacturer assumes no liability for costs incurred to remove or reinstall the product, or for lost revenues due to equipment downtime.
This warranty gives you specifi c legal rights. You may also have other rights which vary from country to country.
Safe-T-Lock 2
TECHNICAL SPECIFICATIONS
INPUT: 12-120 vdc 0.5 amps / 10mA in stand by mode
OUTPUT: Relay contact rating : 10 amp up to 24 vdc, 1amp 36 vdc and higher
For bigger loads, an external relay must be used.
CONSTRUCTION: Epoxy encapsulated electronics, unit is rated IP65. There are no user serviceable parts in this unit.
DIMENSIONS
3.94” / 100 mm
0.16” /
4 mm
0.94” /
24 mm
4.23” / 107 mm
4.23” / 107 mm
3.52” / 89 mm
0.62” / 16 mm
0.14” / 3.5 mm
2.72” / 69 mm
1.41” / 36 mm
The Safe-T-Lock code switch unit offers a high level of security to prevent unauthorized use of equipment. In order to set up, program, operate and retrieve data from the unit, two modes of operation are provided, supervisor and user.
Supervisor mode allows access to the following functions:
• Change Supervisor PIN (Personal Identifi cation Number)
• Adding/Deleting Users
• Last User Identifi cation
• Maintenance cycle menu
User mode allows access to the vehicle along with the ability to perform the following functions:
• Change User PIN
• Operate equipment
OVERVIEW
Safe-T-Lock 3
Accessing Supervisor Menu:
1. Enter supervisor menu by depressing ‘00’
2. Enter supervisor code (4-8 digit)
3. Depress Power/Enter > High pitched tone accompanied by green and red LEDs indicates successful
entry to Supervisor Menu. Note: Entry errors are indicated by red LED and low pitch tone.
Note1:
The default Supervisor PIN is factory set to (00) 1234. It is recommended that this code be changed per the instructions in menu option 1 shown below.
Note 2:
If supervisor PIN is lost or forgotten, the unit can be set back to the default (00) 1234 PIN by pressing 1, 3, 7 & 9 simultaneously until the reset tone occurs, followed by 4 fl ashes of the green and red LED (in approximately 5 seconds). Press CE to confi rm.
Note 3:
Confi rmation of key activation is always provided when any key is pressed by means of audible tone and green fl ash of “accept” LED.
Once supervisor menu is entered (as indicated above) the four menu selections are now available:
1. Change Supervisor PIN
2. Add/Delete Users
3. Last User.
4. Maintenance Menu.
Menu Option 1 – Change Supervisor PIN Menu:
1. While in supervisor menu, press 1 followed by Power/Enter key to access Supervisor PIN change menu.
> High Pitch Tone & Single Flash of Red LED indicates successful entry to supervisor PIN programming mode.
2. Enter 4 - 8 digit PIN followed by power/enter key. > Green Accept LED fl ashes once with each key
depression.
3. Enter 4 - 8 digit PIN second time followed by power/enter key. > High pitched tone accompanied by
green and red LEDs indicates successful acceptance of new PIN.
4. Press CE key to save new supervisor PIN > High pitch tone accompanied by green and red LEDs
indicates successful save of new PIN while returning the unit to supervisor menu.
5. Choose another menu option or Press CE to exit the supervisor menu.
Menu Option 2 – Add/ Delete Users
1. While in supervisor menu, press 2 followed by Power/Enter key to access Add/Delete user function.
> High Pitch Tone and two fl ashes of Red LED indicate successful entry to menu option 2.
2. Press two digit user ID (01-99) to be activated, followed by enter/power key. > Unit will either respond
with Green LED / high pitch tone to indicate user ID is available or RED LED/low pitch tone that indicates user ID is already assigned.
3. Press Power/Enter key again to change status of user ID > One of two results may occur:
• Green LED/High Pitch tone indicates user ID active.
or
• Red LED/High Pitch tone indicates user ID inactive.
Note: During the above procedure the user ID status can be toggled between inactive and active modes until desired setting is present by further Power/Enter key depressions.
4. Press CE key to save assigned user > High pitch tone accompanied by green and red LEDs indicates
successful changes to user assignments.
5. Repeat process to Add/Delete additional users or press CE to exit to Supervisor menu.
SUPERVISOR OPERATION
SUPERVISOR OPERATION
Menu Option 3 – Last User
1. While in supervisor menu, press 3 followed by Power/Enter key to access Last user function. High Pitch
Tone & three fl ashes of Red LED indicate successful entry to Menu option 3.
2. Press Power/Enter key to activate reading of user code.
Note: Code is output as combination of fl ashes from indicator LEDs. The Green LED indicates 10s digit and the Red LED indicates the 1s digit.
Example: 8 Green LED fl ashes followed by 3 Red LED fl ashes means user #83 was last to use vehicle.
3. To re-display last user Press Enter/Power to show code for last user again.
4. Press CE to exit Menu 3 > Green LED high pitch tone accompanied by green and red LEDs indicates
unit has exited Menu 3
5. Choose another menu option or Press CE to exit the supervisor menu.
Menu Option 4 – Maintenance Menu
1. While in supervisor menu, press 4 followed by Power/Enter key to access maintenance function. > High
Pitch Tone & four fl ashes of Red LED indicate successful entry to menu option 4.
2. Press the Enter/Power key to activate the maintenance alarm. > Green LED accompanied by high pitch
tone indicates maintenance alarm is active. Alarm will be set to activate after 250 hours of operation of Safe-T-Lock unit
or
3. To Deactivate Alarm: Press enter key again > Red LED accompanied by high pitch tone indicates
maintenance alarm is inactive.
4. To Reset Maintenance Alarm at the end of 250 hour maintenance period. > Deactivate then reactivate
alarm function as indicated above.
5. Press CE to exit Menu 4 > Green LED high pitch tone accompanied by green and red LEDs indicates
unit has exited Menu 4
6. Choose another menu option or Press CE to exit the supervisor menu.
Exiting Supervisor Menu
After all Supervisor operations have been performed on unit, supervisor menu should be exited by pressing CE key. Note: Leaving unit inactive one minute automatically exits from Supervisor menu which has essentially the same results as Pressing key. Additionally, removing power from unit also will cause unit to exit Supervisor menu.
Safe-T-Lock 4
Typical Operation
1. Enter two digit user ID followed by 4-8 digit PIN.
Note: Default user PIN is 1 2 3 4 (this PIN can be changed as explained below)
2. Press Power/Enter Key > High pitch tone and green LED indicate unit is activated and vehicle is ready
for use. While lock is active, the Green (Accept) LED will occasionally fl ash indicating electronic lock is enabled.
Change of User PIN
1. Enter two digit user code followed by 4-8 digit PIN.
2. Press Power/Enter Key > High pitch tone and green LED indicate unit is activated. Green (Accept) LED
will occasionally fl ash indicating electronic lock is enabled.
Note: During the following procedures vehicle output is deactivated.
3. Press 1 followed by Power/Enter key (within one minute of user entry). > Red Program LED fl ashes once
with key entry.
4. Press new PIN followed by Enter/Power key. > Green Accept LED fl ashes once with key.
5. Re-enter new PIN followed again by Power/Enter key. > Green and Red LEDs will simultaneously fl ash
along with high pitch acceptance tone.
6. New PIN can now be used to access vehicle.
Disabling Vehicle
Three options:
1. Press Power/Enter Key
2. Turn truck ignition off. (See wiring diagram for units with key switch)
3. Automatic Time-Out: Absence of positive or negative voltage on gray wire will cause unit to
automatically shut off after three minute period. (See wiring diagrams)
USER OPERATION
Safe-T-Lock 5
SAMPLE LOG
Serial Number Truck Name
USER ID USER NAME (& EMPLOYEE NUMBER)
Safe-T-Lock 6
Safe-T-Lock 7
SAMPLE LOG
Serial Number Truck Name
USER ID USER NAME (& EMPLOYEE NUMBER)
Safe-T-Lock 8
TEMPLATE
0.156” / 4 mm
0.156” / 4 mm
0.625” / 16 mm
Drill holes for #8 / ST3,9 screw (hardware not provided)
INSTALLATION INSTRUCTIONS
Safe-T-Lock 9
CAUTION
Unit to be installed by qualifi ed technician
1. Mount the Safe-T-Lock™ / Safe-T-Lock™ Plus Programmable Code Switch with 2, #8 / ST3,9 screws.
(not provided)Recommend mounting in a easily accessible location, such as on the dash panel.
2. Install provided bushing to protect wire from chafi ng.
3. After connected, make sure the wires are not in tension.
INSTALLATION ON VEHICLES WITHOUT KEY SWITCH
Mounting Panel
Bushing
GRAY
Seat
(1)
Switch
-
-
+
+
BLACK
RED
WHITE
WHITE
RED W/STRIPE
(3)
Fuse 10A
(2)
BATTERY NEGATIVE OR POSITIVE
BATTERY NEGATIVE
BATTERY POSITIVE
POSITIVE FEED TO VEHICLE
(1) Unit will detect if the seat switch is normally open and switch polarity. (2) For bigger loads, an external relay must be used. (3) Connection not required on vehicles without key switch
SAFE
-T-
LOCK
INSTALLATION INSTRUCTIONS
Safe-T-Lock 10
CAUTION
Unit to be installed by qualifi ed technician
(1) Unit will detect switch polarity. Switch must be normally open when seat is unoccupied (2) For bigger loads, an external relay must be used. (3) Automatically logs user out when key is turned off.
INSTALLATION ON VEHICLES WITH KEY SWITCH
Mounting Panel
Bushing
-
-
+
+
Seat
(1)
Switch
BATTERY NEGATIVE OR POSITIVE
BATTERY NEGATIVE
BATTERY POSITIVE
KEY SWITCH
STARTER SOLENOID
(3)
(BAT)
(ION)
(ACC)
(ST)
Fuse 10A
(2)
Positive feed to vehicle
GRAY
BLACK
RED
WHITE
WHITE
RED W/STRIPE
SAFE
-T-
LOCK
Safe-T-Lock 11
Safe-T-Lock 12
EL510-1003 • 03-2008
MODE D’EMPLOI
A lire et à Classer
Safe-T-Lock 1
GARANTIE
• Le Safe-T-Lock™ est une unité cachetée. Enlever ou bricoler sur l’enveloppe en époxyde annulera la garantie.
• Les unités endommagées suite à une surcharge, une mauvaise utilisation ou une mauvaise installation, ne seront pas acceptées en garantie.
• Les unités n’ont pas d’éléments remplaçables.
Avec ce produit vous obtenez une garantie contre les défauts des matériaux ou les manques de la fabrica­tion pour une période de deux ans à partir de la date d’achat. En cas de besoin de ce service, le client doit envoyer le produit afi n que la garantie puisse être considérée. Tous les produits qui demandent un retour en garantie doivent être envoyés dans les deux ans à partir de la date d’achat. Cette garantie n’est pas valable pour la fi nition et les dégâts causés par une mauvaise installation ou utilisation.
Le fabricant n’est pas responsable des frais créés en enlevant ou en réinstallant le produit, ni de la perte de revenues suite au fait que l’équipement n’a pas pu être utilisé pendant une certaine période.
Avec cette garantie vous obtenez certains droits légaux. Il est possible que vous avez d’autres droits si vous vous trouvez dans un autre pays.
INTERRUPTEUR CODE PROGRAMMABLE
Safe-T-Lock 2
SPECIFICATIONS TECHNIQUES
INPUT: 12-120 vdc 0.5 amp / 10 mA en mode stand by
OUTPUT: Puissance contact relais: 10 amp à 24 vdc, 1 amp 36 vdc et plus
Pour des charges plus importantes, il faut utiliser un relais externe.
CONSTRUCTION: Electronique enfermée dans de l’époxyde, unité IP65. Dans cette unité, il n’y a pas de parties remplaçables
DIMENSIONS
3.94” / 100 mm
0.16” /
4 mm
0.94” /
24 mm
4.23” / 107 mm
4.23” / 107 mm
3.52” / 89 mm
0.62” / 16 mm
0.14” / 3.5 mm
2.72” / 69 mm
1.41” / 36 mm
Le Safe-T-Lock empêche toute utilisation non autorisée de votre chariot. Pour démarrer, programmer et retirer des données de l’unité, deux modes opératoires sont fournies: superviseur et utilisateur.
Menu Superviseur permet de:
• Changer code PIN superviseur (Numéro d’Identifi cation Personnel)
• Ajouter/effacer des utilisateurs
• Dernier Utilisateur
• Menu d’Entretien
Menu Utilisateur permet de:
• Changer code PIN utilisateur
• Faire fonctionner le chariot
APERÇU
Safe-T-Lock 3
Accès au menu Superviseur:
1. Appuyez ‘00’
2. Donnez le code PIN du superviseur (4-8 chiffres)
3. Appuyez sur la touche Enter > Un signal sonore aigu et le LED vert pour confi rmer que le code a été
accepté. Un mauvais code sera reconnu par un signal sonore bas et un LED rouge.
Remarque 1:
Le code 00 ID est réservé au superviseur. Le Numéro d’Identifi cation Personnel (code PIN) standard du superviseur est le 1234. Pour des raisons de sécurité, créez un nouveau code PIN dès que possible.
Remarque 2:
Si le code pin superviseur est peru ou oublié, l’unité peut être remise à zéro, code pin 1234 en appuyant simultanément sur le 1, 3, 7 & 9 jusqu’à ce que vous entendez le signal de remise à zéro, suivi de 4 clignot­tements du LED vert et rouge (dans les 5 secondes). Appuyez sur CE pour confi rmer.
Remarque 3:
Un signal sonore et le LED vert pour confi rmer que le code a été accepté. Après avoir programmé le menu Superviseur, vous pouvez programmer les 4 paramètres suivants:
1. Changer code PIN superviseur
2. Ajouter/effacer des utilisateurs
3. Dernier Utilisateur
4. Menu d’Entretien
Menu Option 1 - Changer code PIN Superviseur:
1. Dans le menu Superviseur, appuyez “1” suivi de Enter > Signal sonore aigu, LED rouge confi rme le
menu superviseur.
2. Donnez le nouveau code PIN suivi par Enter. (4-8 chiffres) > LED vert s’allume après chaque entrée des
chiffres.
3. Répétez le code PIN et appuyez sur la touche Enter pour confi rmer > signal sonore aigu, LED vert et
rouge indiquent que la modifi cation a réussi.
(Une mauvaise procédure sera reconnue par un signal sonore bas et un LED rouge)
4. Pour recommencer, appuyez la touche CE n’importe quand avant le signal sonore.
Appuyez la touche CE après le signal sonore pour retourner au menu superviseur.
5. Choisissez une autre option dans le menu ou appuyez sur CE pour quitter le menu supervisor.
Menu Option 2 – Ajouter/Effacer des utilisateurs:
1. Dans le menu superviseur: appuyez “2” suivi de Enter pour accéder au menu. > signal sonore aigu et 2
fl ashes du LED rouge confi rme le menu.
2. Donnez le code ID d’utilisateur comportant deux chiffres (01-99) et appuyez sur enter
Un fl ash du LED rouge et un signal sonore indiquent que le code ID d’utilisateur est déjà utilisé. Un fl ash du LED vert et un signal sonore indiquent que le code ID d’utilisateur est disponible.
3. Pour modifi er un code ID utilisateur, appuyez sur la touche ENTER; 2 possibilités:
• Le LED vert clignotera pour indiquer que l’ID utilisateur est actif
ou
• Le LED rouge clignotera pour indiquer que l’ID utilisateur est inactif.
Remarque: Pendant la procédure ci-dessus, vous pouvez changer les codes ID utilisateur entre actif et inactif jusqu’au résultat voulu.
4. Appuyez la touche CE pour sauvegarder le code > signal sonore aigu et LED vert et rouge
confi rment.
5. Répétez ces étappes ou appuyez sur la touche CE pour retourner au menu superviseur.
OPERATION PAR LE SUPERVISEUR
OPERATION PAR LE SUPERVISEUR
Menu Option 3 – Dernier utilisateur
1. Dans le menu superviseur: appuyez “3” suivi par Enter pour accéder au menu Dernier Utilisateur >
signal sonore aigu et LED rouge cligndera 3x pour confi rmer
2. Appuyez sur la touche Enter pour consulter le ID utilisateur.
Remarque: Les LEDS clignotants indiqueront le dernier code ID d’utilisateur (01-99). fl ash LED vert pour les dizaines. fl ash LED rouge pour les unités.
Example: 8 x vert, 3 x rouge: utilisateur 83 était le dernier utilisateur
3. Appuyez sur la touche Enter pour répéter ce procédé.
4. Appuyez sur la touche CE pour retourner au menu superviseur: Un son aigu accompagné d’un clignot-
tement des LED vertes et rouges, indiquent que l’unité a quitté le Menu 3
5. Choisissez une autre option dans le menu ou appuyez sur CE pour quitter le menu supervisor.
Menu Option 4 – Menu d’Entretien
1. Dans le menu superviseur: appuyez “4” suivi par Enter pour accéder au menu Entretien > signal sonore
aigu et 4 x LED rouge confi rme le menu d’entretien.
2. Appuyez sur la touche Enter pour activer l’alarme. Signal sonore aigu et le LED vert clignotera lorsque
l’alarme est activée: l’alarme est activé pour fonctionner après 250 heures d’utlisation.
ou
3. Pour désactiver l’alarme, appuyez sur la touche ENTER > signal sonore aigu et LED rouge confi rme la
désactivation.
4. Pour remettre à zéro l’alarme après les 250 heures > désactiver l’alarme et activez-le ensuite comme
décrit ci-dessus.
5. Appuyez sur la touche CE pour retourner au menu superviseur > Un son aigu accompagné d’un clignot-
tement des LED vertes et rouges, indiquent que l’unité a quitté le Menu 4
6. Choisissez une autre option dans le menu ou appuyez sur CE pour quitter le menu supervisor.
Pour quitter le Menu Superviseur:
Appuyez sur la touche CE. L’unité superviseur sera automatiquement désactivé 1 minute après que la dernière touche a été appuyée. Coupez l’unité pour quitter le menu Superviseur
Safe-T-Lock 4
Utilisation correcte
1. Entrez le code ID de deux chiffres de l’utilisateur, et puis donner le code PIN comportant 4-8 chiffres.
Note: La première fois qu’un certain code ID d’utilisateur est utilisé, le code PIN est le 1234. Pour des
raisons de sécurité, changez ce code dans le code de votre choix
2. Appuyez sur la touche Enter. Le LED vert clignotera et vous entendrez un signal sonore, le chariot est
pret. Le LED vert clignotera pendant que le chariot est actif (Le LED clignotera toutes les 3 secondes).
Modifi cation du code PIN Utilisateur
1. Donnez le code ID de deux chiffres de l’utilisateur, suivi par le code PIN actuel de 4-8 chiffres.
2. Appuyez sur la touche Enter > Le LED vert clignotera et vous entendrez un signal sonore aigu, le chariot
est pret. Le LED vert clignotera pendant que le chariot est actif
Remarque: Pendant les procédures ci-dessous, chaque puissance du véchicule est débranchée.
3. Appuyez sur 1, puis sur Enter (avant 1 minute). > LED rouge clignote à chaque touche
4. Donnez le nouveau code PIN et appuyez sur Enter. > LED vert clignotera à chaque touche
5. Répétez le nouveau code PIN et appuyez sur Enter > Le signal sonore aigu et le LED rouge et vert
indiqueront que la modifi cation a réussie .
6. Le nouveau code PIN peut être utilisé.
Désactiver le chariot
3 options:
1. Appuyez sur la touche Enter
2. Coupez le contact du chariot. (voir schéma câblage pour unités)
3. Automatic Seat Time Out: Si l’utilisateur quitte le siège pendant plus de 3 minutes, l’Interrupteur Codé
Programmable effectuera automatiquement un log off de l’utilisateur (voir schéma câblage)
UTILISATION
Safe-T-Lock 5
EXEMPLE JOURNAL
Numéro de série Nom du chariot
CODE ID DE L’UTILISATEUR NOM DE L’UTILISATEUR (& NUMÉRO D’EMPLOYÉ)
Safe-T-Lock 6
Loading...