Tuzio® Woodstock
Towel Warmer
Installation Guide
Code: H6013 / H6014 / H6016
26.5” x 37” x 5.5” Hydronic
Technical Helpline:
Toll-Free 1-877-757-8990
www.icocanada.com
Congratulations!
You are the proud owner of a quality Tuzio Towel Warmer.
This product has been specifically engineered and tested to provide
optimal comfort and satisfaction.
ICO carries a broad range of luxury bathroom products designed to make
everyday living just a little more enjoyable! Visit www.icocanada.com to
learn more.
Contents
Rough-In Requirements For Constant Circulation Heating System Page 3
Rough-In Requirements For Dedicated Heating System Page 4
Installation Instructions Page 5
Valve Connection Page 5
Specifications & Drawings – Wall Rough-In Page 6
Specifications & Drawings – Floor Rough-In Page 7
2
Towel Warmer Installation Procedure
1
Rough-in Requirements - for constant circulation heating system (see figure 1)
Using this installation method, the towel warmer is controlled using the valves attached to the towel warmer, and can be
operated independently from the heating system. This method of installation is popular where there are multiple heating
appliances connected to a closed hot water heating system, and electronic control of the individual towel warmer is not
important.
1. Install heating system pipework to proposed towel warmer location and tee off the main circuit to provide a branch
circuit for the towel warmer. Piping to towel warmer valves should be 1/2” copper.
2. If towel warmer supply pipes are coming through wall, rough-in pipes as per locations shown on fig 4. If towel warmer
supply pipes are coming through floor, rough-in pipes as per locations shown on fig 7.
3. If a hydronic installation pack is being used (see figs 5 & 8), these should be connected (solder connected) within the
wall / floor. If a hydronic installation pack is not being used (see figs 6 & 9), these 1/2” copper supply lines should
protrude through wall/floor in order to connect to towel warmer valves.
4. Wall studs or plywood backing is required in the wall at bracket locations. See figure 4 for bracket locations.
fig. 1