Turner BioSystems TBS-380 User Manual

www.turnerbiosystems.com
Users Manual
TBS-380
Mini-Fluorometer
Dated: 08/14/2007
Rev. E
Phone: (408) 636-2400 Toll Free: (888) 636.2401 Fax: (408) 737-7919
645 N. Mary Avenue Sunnyvale, CA 94085
For the most current version of this manual, visit our
Customer Care Center at www.turnerbiosystems.com
Table of Contents
Introduction
1.
1.1. Description ................................................................................................................................................. 3
1.2. Unpacking and Inspection .......................................................................................................................... 3
1.3. General Information and Precautions ......................................................................................................... 3
2. Quick View Diagram ......................................................................................................................................... 4
3. Instrument Parameters
3.1. Setup Flowchart ......................................................................................................................................... 6
3.2. Instrument Power Up .................................................................................................................................. 8
3.3. Fluorescence Channels .............................................................................................................................. 8
3.4. Calibration Standard Value ......................................................................................................................... 8
3.5. Calibration .................................................................................................................................................. 8
3.6. Sample Analysis ......................................................................................................................................... 9
3.7. Internal Data Logging (IDL) ...................................................................................................................... 10
3.8. Diagnostic Information .............................................................................................................................. 10
3.9. Solid Standard .......................................................................................................................................... 10
4. General Considerations for Analysis
4.1. Handling Samples .................................................................................................................................... 11
4.2. Linear Range and Quenching ................................................................................................................... 11
4.3. Temperature Considerations .................................................................................................................... 11
4.4. Positioning Samples ................................................................................................................................. 12
4.5. Data Quality .............................................................................................................................................. 12
5. Troubleshooting
5.1. Low or No Reading ................................................................................................................................... 13
5.2. High or Over Reading ............................................................................................................................... 13
5.3. Fluctuating Results ................................................................................................................................... 13
6. Warranty
6.1. Terms ....................................................................................................................................................... 14
6.2. Warranty Service ...................................................................................................................................... 14
6.3. Out-of-Warranty Service ........................................................................................................................... 15
Appendices: A. Instrument Specifications
A1. General Specifications ............................................................................................................................... 16
A2. Optical Specifications ................................................................................................................................ 16
B. Internal Data Logging
B1. Shipping Checklist ..................................................................................................................................... 17
B2. Hardware Requirements ............................................................................................................................ 17
B3. Software Installation .................................................................................................................................. 17
B4. Connecting ................................................................................................................................................ 17
B5. Troubleshooting ........................................................................................................................................ 17
Date
Notes/Information
User Notes and Information
3
1 Introduction
1.1 Description
The TBS-380 Mini-Fluorometer is a dual-channel fluorometer designed for quick, easy, and accurate
fluorescence measurements. When properly calibrated with a standard of known concentration, the TBS­380 displays the actual concentrati on of the m eas ured c om pound. T he ne w Minice ll ada ptor desig n enables the user to measure compounds at a low concentration with a low assay volume (e.g. dsD N A at 1ng/mL using PicoGreen, and RNA at 1 ng/mL using RiboGreen).
1.2 Unpacking and Inspection
Upon receiving your instrument, inspect everything carefully and make sure all accessories are present
(refer to the packing list shipped with the instrument). All shipments include:
TBS-380 Mini-Fluorometer
TBS-380 User’s Manual
TBS-380 Quick Reference Guide
Power supply
RS-232 cable
Spreadsheet Interface software (one CD) and Instructions
1.2.1 Setup
To get started (see Section 2. Quick View Diagram):
1. Position the instrument on a flat surface.
2. Assemble the power supply: choose the proper AC clip for your outlet and slide it on to the AC adaptor.
3. Plug the power supply into the TBS-380 (see Section 2. Quick View Diagram). Be sure to use only the power supply provided with your instrument by Turner BioSystems. Powering the instrument with an unapproved power supply may damage the unit.
4. To turn on the TBS-380, press the ON/OFF button. The instrument takes 5 seconds to warm up. After the warm-up, the TBS-380 is ready for operation.
5. To adjust the brightness of the LCD, press the UP or DOWN ARROW buttons.
1.3 General Information and Precautions
The sample compartment cannot accept glass or quartz cuvettes, except when using Minicell adaptor.
1. A minimum volume of 2 mL is required when using the 10x10 mm cuvette.
2. A minimum volume of 50 µL in a Minicell is required.
3. Avoid having any air bubbles in your sample. They can significantly affect the fluorescence reading.
4. When the Minicell is used, make sure to place the Minicell adaptor in the correct orientation. If BLUE channel is selected, insert the Minicell adaptor in the sample compartment with the tab away from you and the “BLUE” label facing you. If UV channel is selected, insert the Minicell adaptor in the sample compartment with the tab close to you and the “UV” label facing you (see Section 2. Quick View Diagram).
TBS-380 Mini-Fluorometer O perating Manual
4
Serial Port
Power Supply Input
BLUE Position
UV Position
2 Quick View Diagram
Sample Compartment
LCD Screen
ON/OFF button
Positioning the Minicell Adaptor
10x10 mm Cuvette Holders
Minicell Cuvette Holders