Turck Ultrasonic Sensors Catalog Page

Turck Inc.
Ultrasonic Sensors
Assignment 1 standard assignment
… contacts 5 … contacts
Connector type
straight
Connector design H1 M12 × 1
T with teach
button
blank without teach
button
Indication X2 number of
LEDs
Voltage range 8 15…30
VDC
Output mode N NPN
output
P PNP
output
Output function 2 number out-
puts, if > 1
LIU analog output
and voltage
Standard Series – Rectangular Design
Features
The rectangular CK40 with integrated connector or the CP40 variants with ter­minal chamber combine the advantages of a large detection range with a wide opening angle and a very small blind zo­ne. These sensors are thus ideally suited for safe detection of objects that provide
geometry or are moved in a large envi­ronment. Both the switching as well as the measuring devices can be customi­zed easy to use via teach button.
Large measuring range
Very short blind zone
Easy teaching via pin 5 or button
Very large opening angle
Type code
RU 200 – CK40 – LIU2 P 8 X2 T – H1 1 5 1
Range … [cm]
Functional principle RU ultrasonic sensor
Housing CK… rectangular, plastic
connector, dimensions in mm
CP… rectangular, plastic terminal
chamber, dimensions in mm
Teach
22
Ultrasonic Sensors
Standard Series – 40 x 40 – Universal – Switching
General data
Operating mode Diuse mode
Range 5…200 cm Housing material Plastic
Operating voltage 15… 30 VDC Radiation direction straight
DC rated operational current
Output 1 Switching output Ambient temperature 0…+70 °C
Types and Data – Selection table
Type Ident no. Conguration Output
RU200-CK40-2UP8X2T-H1151 1610051 via pin 5 or button PNP M12 x 1
RU200-CK40-2UN8X2T-H1151 1610057 via pin 5 or button NPN M12 x 1
RU200-CP40-2UP8X2T 1610052 via button PNP terminal chamber, Terminal box with cable
RU200-CP40-2UN8X2T 1610055 via button NPN terminal chamber, Terminal box with cable
Variable orientation of active face in 5 directions, switchable between diuse mode and retroreective mode
ultrasonic sensor
≤ 150 mA Protection class IP40
Function
Output 2 Switching output
Connection
gland
gland
Standard Series – 40 x 40 – Universal – Measuring
General data
Operating mode Diuse mode
Range 5…200 cm Housing material Plastic
Operating voltage 15… 30 VDC Radiation direction straight
DC rated operational current
Output 1 Switching output Ambient temperature 0…+70 °C
Types and Data – Selection table
Type Ident no. Conguration Output
RU200-CK40-LIU2P8X2T-H1151 1610053 via pin 5 or button PNP M12 x 1
RU200-CK40-LIU2N8X2T-H1151 1610058 via pin 5 or button NPN M12 x 1
RU200-CP40-LIU2P8X2T 1610054 via button PNP terminal chamber, Terminal box with cable
RU200-CP40-LIU2N8X2T 1610056 via button NPN terminal chamber, Terminal box with cable
ultrasonic sensor
≤ 150 mA Protection class IP40
Function
Output 2 Analog output
Connection
gland
gland
Variable orientation of active face in 5 directions, switchable between diuse mode and retroreective mode
23
Loading...
+ 1 hidden pages