Temperature measurement
with current output and PNP/NPN transistor switching output
output 2 reprogrammable as switching output
TS-516-LI2UPN8X-H1141-L050
Type designation TS-516-LI2UPN8X-H1141-L050
Ident-No. 6840028
Temperature range
Temperature operating range -50…150 °C
Temperature operating range -58…302 °F
Measuring element Pt-100 probe, DIN EN 60751, class A
Accuracy 0.15 °C + 0.002 ∙|t| (-30 …350 °C)
Response time t 0.5 = 6 s / t 0.9 = 15 s in water at 0.2 m/s
Immersion depth (L) 50 mm
■ Housing is rotatable after plugging the
process connection
■ Reading of adjusted values without
tools
■ Recessed pushbutton and keylock for
secure programming
■ Permanent display of temperature unit
(°C, °F, K, Ohm)
■ Temperature peak memory
Wiring Diagram
General description
The TS series is a compact processing unit
with a 4-digit, 7-segment display. Available are
versions with non-rotatable (TS400) or rotatable (TS500) body and various output types.
Power supply
Operating voltage 18…30 VDC
Current consumption
Voltage drop at I
Protective measure SELV; PELV according to EN 50178
Short-circuit/reverse polarity protection yes / yes
Protection type and class IP67 / IP69K / III
Outputs
Output 1 Switching output or IO-Link mode
Output 2 analog or switching output
Switching output
Output function NO/NC programmable, PNP/NPN
Switching point accuracy ± 0.3 K
Rated operational current 0.2 A
Switching frequency
Switching point distance
Switching cycles
Release position -50…+149.8°C
Switching point -49.8…+150°C
Analog output
Operating range 4…20/ 0…20 mA (3-wire)
Load
Accuracy (Lin. + Hys. + Rep.) ± 0.3 K
Remark 0.1% of full scale applies to temperatures > 200 °C
Repeatability 0.1 K
e
ð 50 mA
ð 2 V
ð 180 Hz
ï 0.2 K
ï 100 mil.
ð 0.5 kò
IO-Link
IO-Link Specification Specified acc. to version 1.0
Programming FDT / DTM
Transmission physics corresponds to 3-wire physics (PHY2)
Transmission rate COM 2 / 38.4 kbps
Process data width 16 bit
Measured value information 14 bit
Switchpoint information 1 bit
Frame type 2.2
Genauigkeit ± 0.2 K
Edition • 2018-08-27T16:50:58+02:00
1 / 3 TURCK Inc.
Temperature measurement
with current output and PNP/NPN transistor switching output
output 2 reprogrammable as switching output
TS-516-LI2UPN8X-H1141-L050
Temperature behaviour
Temperature coefficient zero point Tk0 ± 0.15 % of full scale/10 K
Temperature coefficient span T
Ambient conditions
Ambient temperature -40…+80 °C
Storage temperature -40…+80 °C
Vibration resistance 20 g (9…2000 Hz), according to IEC 68-2-6
Shock resistance 50 g (11 ms) , acc. to IEC 68-2-27
EMC EN 61000-4-2 ESD:4 kV CD / 8 kV AD
Housing
Housing material Stainless-steel/Plastic, V2A (1.4305)
Process connection G ½" male thread
Electrical connection Connector, M12 × 1
Pressure resistance 160 bar
Reference conditions acc. to IEC 61298-1
Temperature 15…+25 °C
Atmospheric pressure 860…1060 hPa abs.
Humidity 45…75 % rel.
Auxiliary power 24 VDC
kS
± 0.15 % of full scale/10 K
EN 61000-4-3 HF radiated:15 V/m
EN 61000-4-4 Burst:2 kV
EN 61000-4-5 Surge: 1 kV, 42 Ohm
EN 61000-4-6 HF conducted:10 V
Display
Display 4-digit 7-segment, rotatable by 180°
Switching state 2 × LEDs,Yellow
Programming options switch/release point, hysteresis/window mode, NO/
NC; unit
Unit display 4 x green LED (°C, °F, K, Ohm)
MTTF 255 years acc. to SN 29500 (Ed. 99) 20 °C
Edition • 2018-08-27T16:50:58+02:00
2 / 3 TURCK Inc.