1 About this Document
This safety manual contains all information that is required by users to operate the device in
functional safety systems. Read this manual carefully before using the device.
This document addresses only functional safety according EN ISO 13849-1 and EN/IEC 61508.
Other issues are not considered.
All instructions must be followed in order to assure functional safety.
Always make sure that this is the latest version of the safety manual at www.turck.com.
TheGerman versionis considered the definitive document. Every care was taken in the production of the translations of this document. If there is any uncertainty in its interpretation, refer to
theEnglish version of the safety manual or contact TURCK directly.
2 Scope
This safety manual is valid for the Turck CIP Safety devices TBIP-L4-FDIO1-2IOL and
TBIP-L5-FDIO1-2IOL.
The TBIP-L4-FDIO1-2IOL and TBIP-L5-FDIO1-2IOL are safety block I/O modules for safety applications with CIP Safety over EtherNet/IP™.
The devices provide two safety SIL3-inputs (FDI) to connect 2-channel mechanical safety
switches and electronic safety sensors (OSSD).
Two further SIL3-channels (FDX) can be freely used as inputs (FDI) or outputs (FDO). The safety
outputs serve for the safety shutdown of loads (ohmic up to 2 A).
For non-safety functions, the devices provide four universal In-/outputs (DXP) at ports C4 and
C5 as well as two IO-Link master channels (IOL) at ports C6 and C7 for connecting IO-Link
sensors and IO-Link hubs. Additionally, the IO-Link slots each provide one digital in-/output at
pin2.
The non-safety ports C4, C5 and C7 can be switched-o safe via the internal outputs FSO0 and
FSO1 (see”4.5 Block Diagram” on p.7). This allows a safety shutdown of the connected
sensors and actuators.
4.1 Intended Use
TBIP-L4-FDIO1-2IOL and TBIP-L5-FDIO1-2IOL are decentralized CIP Safety safety modules.
The modules collect field signals and transfer the signals safe to a CIP Safety master.
Thanks to an extended temperature range from -40 to +70 °C and the protection class IP65/
IP67/IP69K, the device can be used in harsh environments directly on the machine.
The device is specified for the operation in industrial environment. If it is used in residential or
mixing areas, radio interference may occur.
4.1.1 Foreseeable Misuse
The devices are not suitable for:
The use in explosive areas
■
Outdoor use
■
The permanent use in liquids
■
4.2 Device Overview
30.2
60.4
24
P1
P2
230.5
218
38.8
C0C1C2C3
X1
6.3
C4C5C6C7
X2
6
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
4.3 Type Labels
TBIP-L5-FDIO1-2IOL
TBIP-L4-FDIO1-2IOL
V1
TBIP-L5-FDIO1-2IOLTBIP-L4-FDIO1-2IOL
Ident-No.: 6814056
Charge code:
YoC:
Hans Turck GmbH & Co. KG
Witzlebenstr.7
D-45472 Mülheim a. d. Ruhr
www.turck.com
4.4 Switches and Connectors
Meaning
X1Power IN
X2Power OUT
C0FDI0/1, safety-related input
C1FDI2/3, safety-related input
C2FDX4/5, safety-related in-/output
C3FDX6/7, safety-related in-/output
C4DXP8/9, standard in-/outputs
C5DXP10/11, standard in-/outputs
C6IOL, IO-Link port1
C7IOL, IO-Link port2 (safe shutdown via FSO 1 possible)
IP addressRotary coding switch for address setting (last byte of the IP address for
P1Ethernet 1
P2Ethernet 2
FEFunctional earth
C0
C1
C2
C3
FE
X2X1
C4
C5
C6
C7
IP Address
P2P1
Ident-No.: 100000360
Charge code:
YoC:
(safe shutdown via FSO0 possible)
(safe shutdown via FSO0 possible)
the safe device side – C3 to C7))
Hans Turck GmbH & Co. KG
Witzlebenstr.7
D-45472 Mülheim a. d. Ruhr
www.turck.com
4.5 Block Diagram
V01.0 | 2017/10
C0
C1
C2
C3
4
FDI0/1FSO0
2
4
FDI2/3
2
4
FDX4/5
2
4
FDX6/7
2
(intern)
FSO1
(intern)
1
5
1
5
1
5
DXP8
DXP9
DXP10
DXP11
IO-Link Port1
DI12 (C/Q)
DXP13
IO-Link Port2
DI14 (C/Q)
DXP15
4
C4
2
4
C5
2
4
C6
2
4
C7
2
7