Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
■ EtherNet/IP™
■ Integrated Ethernet switch
■ 10 Mbps / 100 Mbps supported
■ 2 x male M12, 4-pin, D-coded, Ether-
net-Fieldbus connection
■ 7/8" connector for power supply, 4-pin
■ Two safe digital SIL3-inputs
■ 2 IO-Link Master V1.1 slots
■ Compact Ethernet/IP CIP-safe block I/O
module
■ 4-pin power supply
■ 2 safe digital inputs
■ 2 safe universal digital inputs or out-
Type designationTBIP-L4-FDIO1-2IOL
Ident-No.100000360
Supply
Supply voltage24 VDC
Admissible range20.4…28.8 VDC
Voltage supply connection4-pin male 7/8" connector X1
Electrical isolationgalvanic isolation of the voltage groups V1 and V2,
voltages up to 500 VAC
puts
■ 4 universal digital inputs or outputs
■ 2 IO-Link Master Ports Class A
■ Glass-fiber reinforced housing
■ Shock and vibration tested
■ Fully potted module electronics
■ Protection classes IP65 / IP67 / IP69K
System data
Fieldbus transmission rate10 Mbps/100 Mbps
Fieldbus connection technology2 x M12, 4-pin, D-coded
Web serverintegrated
Service interfaceEthernet via P1 or P2
EtherNet/IP™
Addressingacc. to EtherNet/IP™ specification
Quick Connect (QC)< 150 ms
Device Level Ring (DLR)supported
Class 1 connections3
Safety Data
PL acc. to DIN EN 13849-1:2008e
Category acc. to DIN EN 13849-1:20084
SIL according IEC 615083
Useful Lifetime20 Jahre (EN ISO 13849-1)
Safety Inputs OSSD
Low level signal voltageEN 61131-2 Type 1 ( < 5 V; < 0.5 mA)
High level signal voltageEN 61131-2 Type 1 ( > 15 V; > 2 mA)
Max. OSSD supply per channel2 A per C0, C1, C2, C3,
1.5 A at 70 °C
Please consider derating as shown in figure 1
Max. tolerance test pulse width1 ms
Interval between 2 test pulses, minimum20 ms at 1 ms test pulse width
15 ms at 0.5 ms test pulse width
Safety Inputs floating/antivalent
Max. loop resistance
Max. cable length
Test pulse, typical0.6 ms
Test pulse, maximum0.8 ms
Sensor supplyPower supply V AUX1/T1 max. 2 A
Interval between 2 test pulses, minimum900 ms
Additional informationNo connection to external potential allowed
< 150 ò
max. 1 μF at 150 ò
Limited by line capacity
Please consider derating as shown in figure 1
Figure 1
Figure 2
Edition • 2019-01-15T23:11:57+01:00
1 / 7TURCK Inc.
Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
Safety Outputs
Output current in off state< 5 V
Output current in off state< 1 mA
suitable for inputs according to EN 61131-2 Type 1
Test pulse, typical0.5 ms
Test pulse, maximum1.25 ms
Interval between 2 test pulses, typical500 ms
Interval between 2 test pulses, minimum250 ms
Actuator power supplyPower supply V AUX1/T1 max. 2 A
Please consider derating as shown in figure 1
Max. output current2 A (resistive)
1 A (inductive)
Additional informationThe load must be mechanically or electrically inert to
tolerate the test pulses.
When configured as a PPM switching output the
negative pole of the load should be wired to the M-
terminal of the corresponding output (Pin 2).
Digital inputs
Connectivity inputsM12, 5-pin
Input typePNP
Switching thresholdEN 61131-2 Typ 3, PNP
Low level signal voltage< 5 V
High level signal voltage> 11 V
Low level signal current< 1.5 mA
High level signal current> 2 mA
Input delay2.5 ms
Sensor supplyC4, C5: FSO 0 max. 2 A; 500 mA per input
C6: V AUX1 max. 2 A
C7: FSO1 max. 2 A
Please consider derating as shown in figure 1
Electrical isolationgalvanic isolation to P1/P2
, voltages up to 500 VDC
Connectivity outputsM12, 5-pol
Output current per channel0.5 A, short-circuit proof,
max. 2 A (resistive)/ 1 A (inductive) all std. outputs
Actuator power supplyC4, C5: FSO 0 max. 2 A; 500 mA per output
C6: V AUX1 max. 2 A
C7: FSO1 max. 2 A
Please consider derating as shown in figure 1
IO-Link
Number of channels2
IO-Link specificationVersion 1.1
IO-Link port typeClass A and Class B
Frame typesupports all specified frame types
Supported devicesmax. 32 byte input/32 byte output
Transmission rate4.8 kbps (COM 1) / 38.4 kbps (COM 2) / 230 kbps
(COM 3)
Power supplyPower supply V AUX1 max. 2 A
Please consider derating as shown in figure 1
Standard/Directive conformity
Vibration testacceleration to 20 g
acc. to EN 60068-2-6
Shock testacc. to EN 60068-2-27
Drop and toppleacc. to EN 60068-2-31/IEC 60068-2-32
Electromagnetic compatibilityacc. to EN 61131-2
Approvals and certificatesCE, FCC
UL CertificatecULus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ.
Edition • 2019-01-15T23:11:57+01:00
2 / 7TURCK Inc.
Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
General Information
Dimensions (W x L x H)60.4 x 230.4 x 39mm
Operating temperature-40…+70 °C
Storage temperature-40…+85 °C
Altitudemax. 5000 m
Protection classIP65
IP67
IP69K
Housing materialPA6-GF30
Housing colorBlack
Window materialLexan
Material screw303 stainless steel
Material labelPolycarbonate
Halogen-freeyes
Mounting2 mounting holes � 6.3 mm
The data sheet serves as advance information. For
definitive values see the corresponding product
manual. In this respect, no liability for completeness
and accuracy can be applied to the content of this
data sheet.
Edition • 2019-01-15T23:11:57+01:00
3 / 7TURCK Inc.
Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
Accessories
Ethernet cable (example):
RSSD RSSD 441-2M
Ident no. U-02482
Accessories
Actuator and sensor cable/PUR connection cable (example):
RKC4.5T-2-RSC4.5T/TXY
Ident. no. 6629805
Accessories
Actuator and sensor cable/PUR connection cable (example):
RKC4.5T-2-RSC4.5T/TXY
Ident. no. 6629805
M12 × 1 Ethernet
M12 × 1 Safety Inputs
M12 × 1 Safety I/O Port
Accessories
Actuator and sensor cable/PUR connection cable (example):
RKC4.5T-2-RSC4.5T/TXL
Ident. no. 6625612
Accessories
Actuator and sensor cable/PUR connection cable (example):
Connection of a class A device:
RKC4T-2-RSC4T/TXL
Ident. no. 6625604
Connection of a class B device:
RKC4.5T-2-RSC4.5T/TXL
Ident. no. 6625612
Edition • 2019-01-15T23:11:57+01:00
4 / 7TURCK Inc.
M12 × 1 I/O Port
M12 × 1 IO-Link
Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
Accessories
Actuator and sensor cable/PUR connection cable (example):
Connection of a class A device:
RKC4T-2-RSC4T/TXL
Ident. no. 6625604
Connection of a class B device:
RKC4.5T-2-RSC4.5T/TXL
Ident. no. 6625612
Accessories
Power supply cable (example):
RSM RKM 40-2M
Ident no. U2280-0
M12 × 1 IO-Link
7/8'' Power Supply
Edition • 2019-01-15T23:11:57+01:00
5 / 7TURCK Inc.
Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
Module LED Status
LEDColorStatusDescription
ETH1/ETH2GreenONEthernet Link (100 Mbps)
flashingEthernet communication (100 Mbps)
OFFNo Ethernet link
NSGreenOnActive connection to a master
flashingConnection has been established but
not fully completed
RedOnCommunication Error
flashingOne or more I/O connections
have the time-out status.
Red/Green AlternatingFaulty self-test or configuration
GreenOnDiagnostics disabledMS
GreenFlashingWhen used as a stand-alone
device: Device is in protective mode,
an EtherNet/IP™ client is accessing
the standard I/Os.
RedOnCritical error
RedFlashingCorrectable error
Green/
Red
PWRGreenONPower supply V1 OK
LED Status I/O
LEDColorStatusDescription
0…3ONChannel activeGreen
4…7ONChannel activeGreen
8…11GreenONChannel active
Green/Red alternatingChannel active and overload of supply (input only)
12, 14
(IO-Link Port 1 and 2)
IO-Link Mode
(IO-Link Port 1 and 2)
SIO Mode
13, 15GreenONDigital input or output active
GreenflashingIO-Link communication, process data valid
GreenONDigital Input signal is present12, 14
Flashing alternatelyFaulty self-test or configuration
OFFV1 power off or below defined tolerance of 18 V
flashingSelf test
ONDiscrepancyRed
flashingCross circuit
flashingSelf test (input only)
ONDiscrepancy, overload (output only)Red
flashingCross circuit
ONOverload (output only)Red
flashingOverload of supply
flashingIO-Link communication, process data invalidRed
ONIO-Link supply OK, no IO-Link Communication
OFFPort inactive
OFFNo input signal
ONOutput active with overload/short circuitRed
flashingOverload of supply
OFFInput or output inactive
Edition • 2019-01-15T23:11:57+01:00
6 / 7TURCK Inc.
Hybrid Module for EtherNet/IP and CIP-Safety
Safe Digital Inputs and Outputs, Standard Universal Digital Channels, IO-Link
Master Ports
TBIP-L4-FDIO1-2IOL
Process Data Mapping of the Single Protocols
For more details on the corresponding protocols see manual.
Edition • 2019-01-15T23:11:57+01:00
7 / 7TURCK Inc.