turck TBIL-M1-16DXP-B Instructions For Use Manual

Your Global Automation Partner
TBIL-M1-16DXP-B
I/O Hub with IO-Link
Instructions for Use
2
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com
Table of Contents
1.1 Target groups................................................................................................................ 5
1.2 Explanation of Symbols Used .................................................................................... 5
1.3 Additional Documents ................................................................................................5
1.4 Feedback About These Instructions .........................................................................5
2.1 Product Identification ................................................................................................. 6
2.2 Scope of Delivery.......................................................................................................... 6
2.3 Legal Requirements ..................................................................................................... 6
2.4 Manufacturer and Service........................................................................................... 6
3.1 Intended Use .................................................................................................................7
3.2 General Safety Instructions ........................................................................................7
3.3 Notes on the Use in Safety-Related Applications................................................... 7
4.1 Device Overview...........................................................................................................8
4.1.1 Display Elements...........................................................................................................................8
4.2 Properties and Features.............................................................................................. 8
4.3 Functions and Operating Modes...............................................................................8
6.1 Connecting the Supply Voltage and IO-Link.........................................................10
6.1.1 Supply Concept ..........................................................................................................................11
6.2 Connecting Digital Sensors and Actuators ...........................................................12
7.1 Safety Function...........................................................................................................13
7.1.1 Safety Characteristic Data for the Galvanic Isolation.................................................... 13
7.1.2 Cited Standards .......................................................................................................................... 13
7.2 Safety Planning........................................................................................................... 14
7.3 Safe Commissioning ..................................................................................................14
7.3.1 Installing Connecting Cables Safely.................................................................................... 14
7.3.2 Switch-off Supply Voltage Safely .........................................................................................14
7.3.3 Connecting Sensors and Actuators..................................................................................... 14
7.4 Function Tests.............................................................................................................14
8.1 Parameters...................................................................................................................15
9.1 Process Input Data .....................................................................................................21
9.2 Process Output Data..................................................................................................22
9.3 LED Displays ................................................................................................................23
9.3.1 IO-Link............................................................................................................................................ 23
9.3.2 Channel-LEDs ..............................................................................................................................23
9.4 Evaluating Diagnostic Data......................................................................................24
V01.01 | 2018/11
3
Table of Contents
9.5 IO-Link Events .............................................................................................................26
9.6 IO-Link Error Codes ....................................................................................................26
12.1 Returning Devices ......................................................................................................28
4
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com

1 About These Instructions

These operating instructions describe the structure, functions and the use of the product and will help you to operate the product as intended. Read these instructions carefully before using the product. This is to avoid possible damage to persons, property or the device. Retain the in­structions for future use during the service life of the product. If the product is passed on, pass on these instructions as well.

1.1 Target groups

This document is written for specially trained personnel, and must be read carefully by anyone who is responsible for the mounting, commissioning, operation, maintenance, disassembly or disposal of the device.

1.2 Explanation of Symbols Used

The following symbols are used in these instructions:
DANGER
DANGER indicates a dangerous situation with high risk of death or severe injury if not avoided.
WARNING
WARNING indicates a dangerous situation with medium risk of death or severe in­jury if not avoided.
CAUTION
CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided.
NOTICE
NOTICE indicates a situation which may lead to property damage if not avoided.
NOTE
NOTE indicates tips, recommendations and useful information on specific actions and facts. The notes simplify your work and help you to avoid additional work.
u
a
CALL TO ACTION
This symbol denotes actions that the user must carry out.
RESULTS OF ACTION
This symbol denotes relevant results of actions.

1.3 Additional Documents

The following additional documents are available online at www.turck.com:
n Data sheet n Declaration of Conformity n IO-Link devices commissioning manual

1.4 Feedback About These Instructions

We make every effort to ensure that these instructions are as informative and as clear as pos­sible. If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com.
V01.01 | 2018/11
5
Notes on the Product
Manufacturer and Service

2 Notes on the Product

2.1 Product Identification

These instructions are valid for the following devices:
n TBIL-M1-16DXP-B

2.2 Scope of Delivery

The scope of delivery includes:
n I/O hub n Dummy plugs for M12-connectors n Label clips n Quick Start Guide

2.3 Legal Requirements

The device is subject to the following EC directives:
n 2014/30/EU (electromagnetic compatibility) n 2011/65/EU (RoHS II Directive)

2.4 Manufacturer and Service

Hans Turck GmbH & Co. KG Witzlebenstraße 7 45472 Muelheim an der Ruhr Germany
Turck supports you with your projects, from initial analysis to the commissioning of your applic­ation. The Turck product database contains software tools for programming, configuration or commissioning, data sheets and CAD files in numerous export formats. You can access the product database at the following address: www.turck.de/products For further inquiries in Germany contact the Sales and Service Team on:
n Sales: +49 208 4952-380 n Technology: +49 208 4952-390
Outside Germany, please contact your local Turck representative.
6
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com

3 For Your Safety

The product is designed according to state-of-the-art technology. However, residual risks still exist. Observe the following warnings and safety notices to prevent damage to persons and property. Turck accepts no liability for damage caused by failure to observe these warning and safety notices.

3.1 Intended Use

These devices are designed solely for use in industrial areas. The block module TBIL-M1-16DXP-B is an IO-Link device (Class B) and serves as I/O hub between field devices (sensors/actuators) and the IO-Link master. The hub has 16 I/O channels. Each I/O channel can be used as digital in- or output without additional configuration. The device is designed in IP67/IP69K and can be mounted directly in the field. The devices can be used in safety functions up to Performance Level d (acc. to IEC 13849) and SIL 2 (acc. to ISO 61508). For the outputs at the connectors C4…C7, the supply voltage V2 can be safely switched off by an external safety relay or a safety PLC. The devices may only be used as described in these instructions. Any other use is not in accord­ance with the intended use. Turck accepts no liability for any resulting damage.

3.2 General Safety Instructions

n The device may only be assembled, installed, operated, parameterized and maintained by
professionally-trained personnel.
n The device may only be used in accordance with applicable national and international
regulations, standards and laws.
n The device only meets the EMC requirements for industrial areas and is not suitable for use
in residential areas.

3.3 Notes on the Use in Safety-Related Applications

n For the use in safety-related applications: Observe chapter “Using the device in safety applic-
ations”.
n The device is part of a safety-related overall system. The overall system must always be
evaluated as a whole with regard to the requirements of EN ISO 13849-1 and EN IEC 61508.
n The device is not specified for a certain application. Make sure that application-specific
aspects are considered.
n Replace the device before the end of its service life (see "Safety characteristic data for the
galvanic isolation").
n If there is a fault, e.g. a defective housing, do not use the device. n During operation, surface temperatures may occur that could cause burns if touched. n Perform a function test every 12 months n The devices must not be repaired. If problems occur with regard to functional safety, notify
Turck immediately and return the devices immediately to:
Hans Turck GmbH & Co. KG Witzlebenstraße 7 45472 Muelheim an der Ruhr Germany
V01.01 | 2018/11
7
Product Description
0 8
1 9
2 10
3 11
4 12
5 13
6 14
7 15
C3 C2
C7 C6
C1
C5C0C4
73
107
44.7
32.
150
16
25.2
ø 4.3
54
M12 x 1
27.4
Functions and Operating Modes

4 Product Description

The I/O hub TBIL-M1-16DXP-B connects up to 16 digital sensors or actuators with one IO-Link master port. For the connection of field devices, eight M12 connectors are available. Each I/O channel of the TBIL-M1-16DXP-B can be used as digital in- or output without additional configuration. The I/O hub is connected to the IO-Link master via an M12 female connector. The devices are designed in a fully encapsulated housing with degree of protection IP67/IP69K.

4.1 Device Overview

Fig.1: Dimensions

4.1.1 Display Elements

The device has the following LED indicators:
n IO-Link communication n I/O status

4.2 Properties and Features

n Fibre-glass reinforced housing n Shock and vibration tested n Fully potted module electronics n Protection class IP67/IP69K n IO-Link Class B device with 2 galvanically isolated supply voltages (V1/V2) n IO-Link diagnostics for short-circuit and supply over- and undervoltage n 2 universal digital channels per connector n Metal connectors

4.3 Functions and Operating Modes

The I/O hub TBIL-M1-16DXP-B is an IO-Link Class B device with 2 galvanically isolated supply voltages V1 and V2. The connectors C0…C3 are supplied from V1, the connectors C4…C7 from V2. The two supply voltages are galvanically isolated. This allows that the V2 voltage supply for the outputs at connectors C4...C7 can be safely switched off or not safely for the purpose of en­ergy management. The device provides diagnostics for power supply and short circuit of the sensors and actuators on the IO-Link master.
8
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com

5 Mounting

The device is mounted via four M4 screws on a flat and pre-drilled mounting surface.
Fasten the module to the mounting surface with 4 M4 screws. The maximum tightening
Fig.2: Mounting the device to a mounting plate.
torque for the screws is 0.5 Nm
V01.01 | 2018/11
9
Connecting
1 = 24 VDC (V1) 2 = 24 VDC (V2) 3 = GND (V1) 4 = C/Q (IO-Link) 5 = GND (V2)
4
13
2
5
Connecting the Supply Voltage and IO-Link

6 Connecting

WARNING
Penetration of liquids or foreign objects through leaking connections
Danger to life due to failure of the safety function
Tighten the M12 connectors with a tightening torque of 0.8 Nm.Always seal unused connectors with respective protection caps.

6.1 Connecting the Supply Voltage and IO-Link

WARNING
Defective power supply unit
Danger to life due to dangerous voltages on touchable parts
Only use SELV or PELV power supplies in accordance with EN ISO 13849-2, which
allow a maximum of 60 VDC or 25 VAC in the event of a fault.
A 5-pole M12 connector is available for the connection to IO-Link and the supply voltage.
Fig.3: M12 connector for the connection to IO-Link
Connect the device to the supply voltage and IO-Link according to the pin assignment.
Fig.4: Pin assignment IO-Link
10
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | more@turck.com | www.turck.com