Safety Technology
Multi-Beam Safety Light Curtain
Transceiver
SGSMA2-500Q12
Type designation SGSMA2-500Q12
Ident no. 3803233
Function Light screen
Light type IR
Wavelength 950 nm
Optical resolution 500 mm
Range
Scan field 500 mm
With muting function yes
Ambient temperature 0…+55 °C
Storage temperature -25…+70 °C
Relative humidity 15…95%
Operating voltage 19.2…28.8 VDC
DC rated operational current
Max. current safe output 0.5 mA
Short-circuit protection yes
Reverse polarity protection yes
Output function 2 × OSSD, NO contacts, PNP
Protection class III
Response time typical < 11 ms
Design Rectangular, SGS Safety Grid System
Dimensions 56.9 x 52 x 606.35 mm
Housing material Metal, AL, Yellow polyester
Pollution degree 2
Lens plastic, PMMA
Electrical connection Connectors, M12 × 1
Number of cores 12
Protection class IP65
Vibration resistance 10-55 Hz bei 0,35 mm
Shock test 10 g bei 16 ms (6000 Zyklen)
PL acc. to DIN EN 13849-1:2008 e
Category acc. to DIN EN 13849-1:2008 4
SIL according IEC 61508 3
Useful Lifetime 20 years
Power-on indication LED, Green
ï 0.5…ð 8
ð 500 mA
■ Active emitter/receiver element
■ Light beams: 2
■ Resolution: 500 mm
■ M12 male connector, 12-pin and 5-pin
(muting sensor)
■ Scan codes, automatic/manual — start/
restart, integrated muting, EDM
■ Requires passive reflector element
SGSB2-500
■ Range: 8 m
■ Operating voltage 24 VDC ±20 %
■ Scan field: 500 mm
■ SIL 3 (IEC 61508)
■ PL e (ISO 13849-1)
Functional principle
The SGS multi-beam safety light barrier with
integrated muting is a two-part system consisting of an active transmitter/receiver unit
and a passive reflector unit.
Models are available in 2-beam (500 mm resolution), 3-beam (400 mm resolution) or 4beam (300 mm and 400 mm resolution) versions.
The detection range extends from 0.5 m to 6.5
m (8 m) and is reduced when using deflection
mirrors.
The SGS system can be configured for trip
output (automatic start/restart) or latch output
(manual start/restart).
If the light beams are interrupted, two redundant safety outputs (OSSDs) switch off.
The connected sensors are monitored redundantly via the separate muting sensor connection on the transceiver and automatically interrupt the protective function of the multi-beam
safety light barrier during the safe part of the
machine cycle.
The transceiver has a 7-segment diagnostic
indicator and individual LEDs for continuous
indication of the operating status, configuration and error conditions.
Edition • 2020-11-24T05:52:44+01:00
1 / 1 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ more@turck.com ñ www.turck.com