Turck RU200-CP40-LIU2N8X2T/S10 Data Sheet

Ultrasonic sensor diffuse mode sensor RU200-CP40-LIU2N8X2T/S10
Type designation RU200-CP40-LIU2N8X2T/S10
Ident-No. 1610091
Repeat accuracy
Ambient temperature 0…+70 °C
Separate transducers for transmitter
and receiver
Rectangular housing 40 x 40 x 166 mm
Connection via screw terminals
Terminal chamber for cable gland NPT
Teach range adjustable via button
Blind zone: 5 cm
Range: 200 cm
Resolution: 1 mm
Sonic cone angle: 60°
1 x switching output, NPN
NO/NC programmable
1 x analog output, 4..20mA/ 0..10 V
Wiring Diagram
Operating voltage 15…30 VDC
Residual ripple DC rated operational current No-load current I Residual current Output function 4-wire, NO/NC contact, NPN Short-circuit protection yes/ Cyclic Voltage drop at I Wire breakage/Reverse polarity protection yes/ yes
Design Rectangular, CP40 Dimensions 166 x 40 x 40 mm Housing material Plastic, PBT-GF30-V0 Electrical connection Terminal chamber, Terminal box with cable gland Protection class IP40
Switching state LED yellow
0
e
ð 10 % U ð 150 mA ð 50 mA ð 0.1 mA
ð 2.5 V
ss
Functional principle
Ultrasonic sensors capture a multitude of ob­jects contactless and wear-free with ultrason­ic waves. It does not matter whether the ob­ject is transparent or opaque, metallic or non­metallic, firm, liquid or powdery. Even environ­mental conditions such as spray, dust or rain hardly affect their function.
Sonic Cone
Edition • 2017-01-06T17:57:38+01:00
1 / 2 TURCK Inc.
Ultrasonic sensor diffuse mode sensor RU200-CP40-LIU2N8X2T/S10
Setting the limits
The ultrasonic sensor has an analog and a switching
output with teachable measuring and switching range.
Teaching via buttons on the housing. The green and
yellow LED indicate whether the sensor has detected
an object.
Various functions such as single switchpoint, window
mode or reflection mode to a fixed target can be taught.
Further information is described in the operating in-
structions. How to set the window mode is described
below. The limits of the window may be selected freely
within the detection range.
ñFor the first limit value, place object accordingly ñ Press and hold button 1 to select output 1 or 2 for 2
or 8 s against Gnd
ñ Press and hold button 1 for at least 8 s ñFor the second limit value, place object accordingly ñ Press and hold button 1 for at least 2 s
LED response
Successful teaching is indicated by a fast flashing
green LED. Thereafter, the sensor automatically runs in
normal operating mode. Unsuccessful teaching is indi-
cated by the LED flashing alternately green and yellow.
In normal operating mode both LEDs signal the switch-
ing state of output 1. ñgreen: object is in the detection range but not in the
switching range
ñ yellow: object is in the switching range ñoff: object is outside the detection range or signal loss
Edition • 2017-01-06T17:57:38+01:00
2 / 2 TURCK Inc.
Loading...